# Solax Binding
|
|
|
|
This is a binding for Solax solar power inverters.
|
|
|
|
Solax Wi-Fi module with direct connection via HTTP is supported.
|
|
Wi-Fi module firmware version 3.x+ is required.
|
|
Please note that earlier firmware releases do not support direct connection, therefore the binding will not work in its current state.
|
|
|
|
The binding retrieves a structured data from the inverter's Wi-Fi module, parses it and pushes it into the inverter Thing where each channel represents a specific information (inverter output power, voltage, PV1 power, etc.)
|
|
|
|
In case the parsed information that comes with the binding out of the box differs, the raw data channel can be used with a combination of JSON Path transformation to map the proper values to the necessary items.
|
|
|
|
## Supported Things
|
|
|
|
| Thing | Thing Type | Description |
|
|
|------------------------|------------|-------------------------------------------------------------------------------------|
|
|
| local-connect-inverter | Thing | This is model representation of inverter with all the data available as a channels |
|
|
|
|
Note: Channels may vary depending on the inverter type and the availability of information for parsing the raw data.
|
|
If you're missing a channel this means that it's not supported for your inverter type.
|
|
|
|
## Thing Configuration
|
|
|
|
### Local Connect Inverter Configuration
|
|
|
|
| Parameter | Description |
|
|
|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------|
|
|
| refreshInterval | Defines the refresh interval when the binding polls from the inverter's Wi-Fi module (in seconds). Optional parameter. Default 10 seconds. |
|
|
| password | Password for accessing the Wi-Fi module (the serial number of the wifi). Mandatory parameter. |
|
|
| hostname | IP address or hostname of your Wi-Fi module. If hostname is used must be resolvable by OpenHAB. Mandatory parameter. |
|
|
|
|
### Inverter Output Channels
|
|
|
|
| Channel | Type | Description |
|
|
|---------------------------------|----------------------------|----------------------------------------------------------------|
|
|
| inverter-output-power | Number:Power | The output power of the inverter [W] |
|
|
| inverter-current | Number:ElectricCurrent | The output current of the inverter [A] |
|
|
| inverter-voltage | Number:ElectricPotential | The output voltage of the inverter [V] |
|
|
| inverter-frequency | Number:Frequency | The frequency of the electricity of the inverter [Hz] |
|
|
| inverter-output-power-phase1 | Number:Power | The output power of phase 1 of the inverter [W] |
|
|
| inverter-output-power-phase2 | Number:Power | The output power of phase 2 of the inverter [W] |
|
|
| inverter-output-power-phase3 | Number:Power | The output power of phase 3 of the inverter [W] |
|
|
| inverter-total-output-power | Number:Power | The total output power of all phases of the inverter [W] |
|
|
| inverter-current-phase1 | Number:ElectricCurrent | The output current of phase 1 of the inverter [A] |
|
|
| inverter-current-phase2 | Number:ElectricCurrent | The output current of phase 2 of the inverter [A] |
|
|
| inverter-current-phase3 | Number:ElectricCurrent | The output current of phase 3 of the inverter [A] |
|
|
| inverter-voltage-phase1 | Number:ElectricPotential | The output voltage of phase 1 of the inverter [V] |
|
|
| inverter-voltage-phase2 | Number:ElectricPotential | The output voltage of phase 2 of the inverter [V] |
|
|
| inverter-voltage-phase3 | Number:ElectricPotential | The output voltage of phase 3 of the inverter [V] |
|
|
| inverter-frequency-phase1 | Number:Frequency | The frequency of phase 1 of the inverter [Hz] |
|
|
| inverter-frequency-phase2 | Number:Frequency | The frequency of phase 2 of the inverter [Hz] |
|
|
| inverter-frequency-phase3 | Number:Frequency | The frequency of phase 3 of the inverter [Hz] |
|
|
|
|
### Photovoltaic Panels Production Channels
|
|
|
|
| Channel | Type | Description |
|
|
|--------------------------|----------------------------|-------------------------------------------------|
|
|
| pv1-voltage | Number:ElectricPotential | The voltage of PV1 string [V] |
|
|
| pv2-voltage | Number:ElectricPotential | The voltage of PV2 string [V] |
|
|
| pv1-current | Number:ElectricCurrent | The current of PV1 string [A] |
|
|
| pv2-current | Number:ElectricCurrent | The current of PV2 string [A] |
|
|
| pv1-power | Number:Power | The output power PV1 string [W] |
|
|
| pv2-power | Number:Power | The output power PV2 string [W] |
|
|
| pv-total-power | Number:Power | The total output power of both PV strings [W] |
|
|
| pv-total-current | Number:ElectricCurrent | The total current of both PV strings [A] |
|
|
|
|
### Battery channels
|
|
|
|
| Channel | Type | Description |
|
|
|---------------------------|----------------------------|------------------------------------------------------------------------------------------------|
|
|
| battery-power | Number:Power | The power to / from battery (negative means power is pulled from battery and vice-versa) [W] |
|
|
| battery-current | Number:ElectricCurrent | The current to / from battery (negative means power is pulled from battery and vice-versa) [A] |
|
|
| battery-voltage | Number:ElectricPotential | The voltage of the battery [V] |
|
|
| battery-temperature | Number:Temperature | The temperature of the battery [C/F] |
|
|
| battery-state-of-charge | Number | The state of charge of the battery [%] |
|
|
|
|
### Grid related channels
|
|
|
|
| Channel | Type | Description |
|
|
|--------------------------|----------------------------|------------------------------------------------------------------------------------------------|
|
|
| feed-in-power | Number:Power | The power to / from grid (negative means power is pulled from the grid and vice-versa) [W] |
|
|
|
|
### General channels
|
|
|
|
| Channel | Type | Description |
|
|
|--------------------------|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------|
|
|
| last-update-time | DateTime | Last time when a call has been made to the inverter |
|
|
| raw-data | String | The raw data retrieved from inverter in JSON format. (Usable for channels not implemented. Can be consumed with the JSONpath transformation |
|
|
|
|
### Statistics / Usage related Channels
|
|
|
|
| Channel | Type | Description |
|
|
|----------------------------------|----------------------------|-----------------------------------------------------------|
|
|
| power-usage | Number:Power | Current power usage / consumption of the building [W] |
|
|
| total-energy | Number:Energy | Total energy output from the inverter [kWh] |
|
|
| total-battery-discharge-energy | Number:Energy | Total energy from the battery [kWh] |
|
|
| total-battery-charge-energy | Number:Energy | Total energy to the battery [kWh] |
|
|
| total-pv-energy | Number:Energy | Total energy from the PV [kWh] |
|
|
| total-consumption | Number:Energy | Total energy consumed for the building [kWh] |
|
|
| total-feed-in-energy | Number:Energy | Total energy consumed from the electricity provider [kWh] |
|
|
| today-energy | Number:Energy | Energy output from the inverter for the day [kWh] |
|
|
| today-battery-discharge-energy | Number:Energy | Total energy from the battery output for the day [kWh] |
|
|
| today-battery-charge-energy | Number:Energy | Total energy charged to the battery for the day [kWh] |
|
|
| today-feed-in-energy | Number:Energy | Total energy charged to the battery for the day [kWh] |
|
|
| today-consumption | Number:Energy | Total energy consumed for the day [kWh] |
|
|
|
|
### Properties
|
|
|
|
| Property | Description |
|
|
|-------------------|-------------------------------------------|
|
|
| serialNumber | The serial number of the Wi-Fi module |
|
|
| inverterType | Inverter Type (for example X1_HYBRID_G4) |
|
|
|
|
## Full Example
|
|
|
|
Here are some file based examples.
|
|
|
|
### Thing Configuration
|
|
|
|
```java
|
|
// The local connect inverter thing
|
|
Thing solax:local-connect-inverter:localInverter [ refreshInterval=10, password="<SERIAL NUMBER OF THE WIFI MODULE>", hostname="<local IP/hostname in the network>" ]
|
|
```
|
|
|
|
### Item Configuration
|
|
|
|
```java
|
|
Group gSolaxInverter "Solax Inverter" <energy> (boilerRoom)
|
|
Group solarPanels "Solar panels" <energy> (gSolaxInverter)
|
|
|
|
Number solaxPowerWest "West [%.0f W]" <solarplant> (gsolax_inverter,EveryChangePersist,solarPanels){ channel="solax:local-connect-inverter:localInverter:pv1-power" }
|
|
Number solaxPowerEast "East [%.0f W]" <solarplant> (gsolax_inverter,EveryChangePersist,solarPanels){ channel="solax:local-connect-inverter:localInverter:pv2-power" }
|
|
Number solaxBatteryPower "Battery power [%.0f W]" <energy> (gsolax_inverter,EveryChangePersist) { channel="solax:local-connect-inverter:localInverter:battery-power" }
|
|
Number solaxBatterySoc "Battery SoC [%.0f %%]" <batterylevel> (gsolax_inverter,EveryChangePersist) { channel="solax:local-connect-inverter:localInverter:battery-state-of-charge" }
|
|
|
|
Number solaxFeedInPower "Feed-in power (CEZ) [%.0f W]" <energy> (gsolax_inverter,EveryChangePersist) { channel="solax:local-connect-inverter:localInverter:feed-in-power" }
|
|
Number solaxAcPower "Invertor output power [%.0f W]" <energy> (gsolax_inverter,EveryChangePersist){ channel="solax:local-connect-inverter:localInverter:inverter-output-power" }
|
|
|
|
String solaxInverterType "Inverter Type [%s]" <energy> (gsolax_inverter) { channel="solax:local-connect-inverter:localInverter:inverter-type"}
|
|
String solaxUploadTime "Last update time [%s]" <calendar> (gsolax_inverter) { channel="solax:local-connect-inverter:localInverter:last-update-time" }
|
|
String solaxRawData "Raw data [%s]" <data> (gsolax_inverter) { channel="solax:local-connect-inverter:localInverter:raw-data" }
|
|
```
|
|
|
|
### Sitemap Configuration
|
|
|
|
```perl
|
|
Frame label="Solar power strings" {
|
|
Text item=solaxPowerEast valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"] {
|
|
Text item=solaxPowerEast icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Text item=solaxPowerWest icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Chart item=solarPanels period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solarPanels period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solarPanels period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solarPanels period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solarPanels period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
Text item=solaxPowerWest valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"] {
|
|
Text item=solaxPowerEast icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Text item=solaxPowerWest icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Chart item=solarPanels period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solarPanels period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solarPanels period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solarPanels period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solarPanels period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
Text item=solaxGenerationTotal valuecolor=[<=100="gray",<=500="red", <2000="orange", >=2000="green"] {
|
|
Text item=solaxPowerEast icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Text item=solaxPowerWest icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Text item=solaxGenerationTotal icon="energy" valuecolor=[<=30="gray",<=300="red", <1500="orange", >=1500="green"]
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Chart item=solarPanels period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solarPanels period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solarPanels period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solarPanels period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solarPanels period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
}
|
|
Frame label="Consumption" {
|
|
Text item=solaxAcPower valuecolor=[<=30="gray", <800="green", <1500="orange", >=1500="red"] {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Text item=solaxAcPower icon="energy" valuecolor=[<=30="gray", <800="green", <1500="orange", >=1500="red"]
|
|
Chart item=solaxAcPower period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solaxAcPower period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solaxAcPower period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solaxAcPower period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solaxAcPower period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
Text item=solaxFeedInPower valuecolor=[<=30="gray", <800="green", <1500="orange", >=1500="red"] {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Text item=solaxFeedInPower icon="energy" valuecolor=[<=30="gray", <800="green", <1500="orange", >=1500="red"]
|
|
Chart item=solaxFeedInPower period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solaxFeedInPower period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solaxFeedInPower period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solaxFeedInPower period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solaxFeedInPower period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
}
|
|
Frame label="Battery" {
|
|
Text item=solaxBatteryPower valuecolor=[<=-500="red", <0="orange", ==0="gray", >0="green"] {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Text item=solaxBatteryPower icon="energy" valuecolor=[<-800="red", <0="orange", ==0="gray", >=0="green"]
|
|
Chart item=solaxBatteryPower period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solaxBatteryPower period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solaxBatteryPower period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solaxBatteryPower period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solaxBatteryPower period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
Text item=solaxBatterySoc valuecolor=[<=30="red", <50="orange", >=50="green"] {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="H", 1="D", 2="W", 3="M", 4="Y"]
|
|
Text item=solaxBatterySoc valuecolor=[<=30="red", <50="orange", >=50="green"]
|
|
Chart item=solaxBatterySoc period=h refresh=600 visibility=[Chart_Period==0]
|
|
Chart item=solaxBatterySoc period=D refresh=3600 visibility=[Chart_Period==1]
|
|
Chart item=solaxBatterySoc period=W refresh=3600 visibility=[Chart_Period==2, Chart_Period==Uninitialized]
|
|
Chart item=solaxBatterySoc period=M refresh=3600 visibility=[Chart_Period==3]
|
|
Chart item=solaxBatterySoc period=Y refresh=3600 visibility=[Chart_Period==4]
|
|
}
|
|
}
|
|
```
|
|
|
|
|