mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-11 15:42:10 +01:00
a0236bf993
Signed-off-by: Jimmy Tanagra <jcode@tanagra.id.au>
185 lines
17 KiB
Markdown
185 lines
17 KiB
Markdown
# Fronius Binding
|
|
|
|
This binding uses the [Fronius Solar API V1](https://www.fronius.com/en/photovoltaics/products/all-products/system-monitoring/open-interfaces/fronius-solar-api-json-) to obtain data from Fronius devices.
|
|
|
|
It supports Fronius inverters and Fronius Smart Meter. Supports:
|
|
* Fronius Symo
|
|
* Fronius Symo Gen24
|
|
* Fronius Smart Meter 63A
|
|
* Fronius Smart Meter TS 65A-3
|
|
* Fronius Ohmpilot
|
|
|
|
## Supported Things
|
|
|
|
| Thing Type | Description |
|
|
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
|
| `bridge` | The Bridge |
|
|
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
|
|
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0)
|
|
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0)
|
|
|
|
|
|
## Discovery
|
|
|
|
There is no discovery implemented. You have to create your things manually and specify the hostname or IP address of the Datalogger and the device id.
|
|
|
|
## Binding Configuration
|
|
|
|
The binding has no configuration options, all configuration is done at `bridge`, `powerinverter`, `meter` or `ohmpilot` level.
|
|
|
|
## Thing Configuration
|
|
|
|
### Bridge Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ----------------- | ----------------------------------------------------- |
|
|
| `hostname` | The hostname or IP address of your Fronius Datalogger |
|
|
| `refreshInterval` | Refresh interval in seconds |
|
|
|
|
### Powerinverter Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | ------------------------------------------ |
|
|
| `deviceId` | The identifier of your device (Default: 1) |
|
|
|
|
### Meter Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | ----------------------------------------------- |
|
|
| `deviceId` | The identifier of your smart meter (Default: 0) |
|
|
|
|
### Ohmpilot Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | ----------------------------------------------- |
|
|
| `deviceId` | The identifier of your ohmpilot (Default: 0) |
|
|
|
|
## Channels
|
|
|
|
### Channels for `powerinverter` Thing
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ------------------------------------ | --------- | ----------------------------------------------------------------------------------------------------------------- |
|
|
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
|
|
| `inverterdatachannelpac` | Number | AC power |
|
|
| `inverterdatachanneltotal` | Number | Energy generated overall |
|
|
| `inverterdatachannelyear` | Number | Energy generated in current year |
|
|
| `inverterdatachannelfac` | Number | AC frequency |
|
|
| `inverterdatachanneliac` | Number | AC current |
|
|
| `inverterdatachannelidc` | Number | DC current |
|
|
| `inverterdatachanneluac` | Number | AC voltage |
|
|
| `inverterdatachanneludc` | Number | DC voltage |
|
|
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
|
|
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
|
| `powerflowchannelpgrid` | Number | Power + from grid, - to grid |
|
|
| `powerflowchannelpload` | Number | Power + generator, - consumer |
|
|
| `powerflowchannelpakku` | Number | Power + charge, - discharge |
|
|
|
|
### Channels for `meter` Thing
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
|
| `enable` | Number | 1 = enabled, 0 = disabled |
|
|
| `location` | Number | 0 = grid interconnection point (primary meter)<br/> 1 = load (primary meter) <br />3 = external generator (secondary meters)(multiple)<br />256-511 = subloads (secondary meters)(unique). Refer to Fronius Solar API. |
|
|
| `currentacphase1` | Number:ElectricCurrent | AC Current on Phase 1 |
|
|
| `currentacphase2` | Number:ElectricCurrent | AC Current on Phase 2 |
|
|
| `currentacphase3` | Number:ElectricCurrent | AC Current on Phase 3 |
|
|
| `voltageacphase1` | Number:ElectricPotential | AC Voltage on Phase 1 |
|
|
| `voltageacphase2` | Number:ElectricPotential | AC Voltage on Phase 2 |
|
|
| `voltageacphase3` | Number:ElectricPotential | AC Voltage on Phase 3 |
|
|
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
|
|
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
|
|
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
|
|
| `powerrealsum` | Number:Power | Real Power summed up |
|
|
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
|
|
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
|
|
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
|
|
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
|
| `energyrealsumproduced` | Number:Energy | Real Energy produced |
|
|
| |
|
|
|
|
|
|
### Channels for `ohmpilot` Thing
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
|
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
|
| `powerrealsum` | Number:Power | Real Power |
|
|
| `temperaturechannel1` | Number:Temperature | Temperature |
|
|
| `errorcode` | Number | Device error code |
|
|
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
|
|
| |
|
|
|
|
|
|
## Properties
|
|
|
|
### The `meter` thing has the following properties:
|
|
|
|
| Property | Description |
|
|
| -------- | ------------------------------ |
|
|
| `modelId` | The model name of the meter |
|
|
| `serialNumber` | The serial number of the meter |
|
|
|
|
### The `ohmpilot` thing has the following property:
|
|
|
|
| Property | Description |
|
|
| -------- | ------------------------------ |
|
|
| `modelId` | The model name of the ohmpilot |
|
|
| `serialNumber` | The serial number of the ohmpilot |
|
|
|
|
## Full Example
|
|
|
|
demo.things:
|
|
|
|
```
|
|
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
|
|
Thing powerinverter myinverter [deviceId=1]
|
|
Thing meter mymeter [deviceId=0]
|
|
Thing ohmpilot myohmpilot [deviceId=0]
|
|
}
|
|
```
|
|
|
|
demo.items:
|
|
|
|
```
|
|
Number AC_Power { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
|
|
Number Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
|
|
Number Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
|
|
Number Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
|
|
Number FAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelfac" }
|
|
Number IAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneliac" }
|
|
Number IDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelidc" }
|
|
Number UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneluac" }
|
|
Number UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
|
|
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
|
|
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
|
|
Number Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
|
|
Number Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
|
|
Number Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
|
|
|
|
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
|
|
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
|
|
Number:ElectricCurrent Meter_CurrentPhase1 { channel="fronius:meter:mybridge:mymeter:currentacphase1" }
|
|
Number:ElectricCurrent Meter_CurrentPhase2 { channel="fronius:meter:mybridge:mymeter:currentacphase2" }
|
|
Number:ElectricCurrent Meter_CurrentPhase3 { channel="fronius:meter:mybridge:mymeter:currentacphase3" }
|
|
Number:Voltage Meter_VoltagePhase1 { channel="fronius:meter:mybridge:mymeter:voltageacphase1" }
|
|
Number:Voltage Meter_VoltagePhase2 { channel="fronius:meter:mybridge:mymeter:voltageacphase2" }
|
|
Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:voltageacphase3" }
|
|
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
|
|
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
|
|
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
|
|
Number:Power Meter_PowerSum { channel="fronius:meter:mybridge:mymeter:powerrealsum" }
|
|
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
|
|
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
|
|
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
|
|
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
|
|
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
|
|
|
|
Number:Energy Ohmpilot_EnergyConsumed { channel="fronius:ohmpilot:mybridge:myohmpilot:energyrealsumconsumed" }
|
|
Number:Power Ohmpilot_PowerSum { channel="fronius:ohmpilot:mybridge:myohmpilot:powerrealsum" }
|
|
Number:Temperature Ohmpilot_Temperature { channel="fronius:ohmpilot:mybridge:myohmpilot:temperaturechannel1" }
|
|
Number Ohmpilot_State { channel="fronius:ohmpilot:mybridge:myohmpilot:statecode" }
|
|