# Daikin Binding
|
|
|
|
The Daikin binding allows you to control your Daikin air conditioning units with openHAB.
|
|
|
|
In order to do so, your Daikin air conditioning unit must have a supported Wi-Fi adapter installed.
|
|
This may work with the older KRP series of wired adapters, but has not been tested with them.
|
|
|
|
## Supported Things
|
|
|
|
| Thing | Daikin Wi-Fi Adapter Model |
|
|
| ----------------- | ------------------------------------------ |
|
|
| `ac_unit` | BRP069A81, BRP069B41, BRP072A42, BRP072C42 |
|
|
| `airbase_ac_unit` | BRP15B61 |
|
|
|
|
## Discovery
|
|
|
|
This add-on will broadcast messages on your local network looking for Daikin air conditioning units and adding them to the queue of new items discovered.
|
|
You can also manually add a new item if you know the IP address.
|
|
|
|
Background discovery polls the network every minute for devices.
|
|
Background discovery is **enabled** by default.
|
|
To **disable** background discovery, add the following line to the _conf/services/runtime.cfg_ file:
|
|
|
|
```ini
|
|
discovery.daikin:background=false
|
|
```
|
|
|
|
### BRP072C42 adapter discovery
|
|
|
|
A BRP072C42 adapter requires a registered UUID to authenticate. Upon discovery, a UUID will be generated but the adapter's key must be entered in the Thing configuration to complete the UUID registration.
|
|
|
|
## Thing Configuration
|
|
|
|
- `host` - The hostname of the Daikin air conditioner. Typically you'd use an IP address such as `192.168.0.5` for this field.
|
|
- `refresh` - The frequency with which to refresh information from the Daikin air conditioner specified in seconds. Defaults to 60 seconds.
|
|
|
|
### Additional Thing configurations for BRP072C42 adapter
|
|
|
|
- `secure` - Must be set to true for BRP072C42 to access it through https.
|
|
- `uuid` - A UUID used to access the BRP072C42 adapter. A handy UUID generator can be found at <https://www.uuidgenerator.net/>.
|
|
- `key` - The 13-digit key from the Daikin adapter.
|
|
|
|
## Channels
|
|
|
|
The temperature channels have a precision of one half degree Celsius.
|
|
For the BRP072A42 and BRP072C42:
|
|
|
|
| Channel Name | Description |
|
|
| --------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
|
| power | Turns the power on/off for the air conditioning unit. |
|
|
| settemp | The temperature set for the air conditioning unit. |
|
|
| indoortemp | The indoor temperature as measured by the unit. |
|
|
| outdoortemp | The outdoor temperature as measured by the external part of the air conditioning system. May not be available when unit is off. |
|
|
| humidity | The indoor humidity as measured by the unit. This is not available on all units. |
|
|
| mode | The mode set for the unit (AUTO, DEHUMIDIFIER, COLD, HEAT, FAN) |
|
|
| homekitmode | A mode that is compatible with homekit/alexa/google home (off, auto, heat, cool). Not tested for BRP069B41 |
|
|
| fanspeed | The fan speed set for the unit (AUTO, SILENCE, LEVEL_1, LEVEL_2, LEVEL_3, LEVEL_4, LEVEL_5) |
|
|
| fandir | The fan blade direction (STOPPED, VERTICAL, HORIZONTAL, VERTICAL_AND_HORIZONTAL) |
|
|
| cmpfrequency | The compressor frequency |
|
|
| specialmode | The special mode set for the unit (NORMAL, ECO, POWERFUL). This is not available on all units. |
|
|
| streamer | Turns the streamer feature on/off for the air conditioning unit. This is not available on all units. |
|
|
| energyheatingtoday | The energy consumption when heating for today |
|
|
| energyheatingthisweek | The energy consumption when heating for this week |
|
|
| energyheatinglastweek | The energy consumption when heating for last week |
|
|
| energyheatingcurrentyear-1 | The energy consumption when heating for current year January |
|
|
| energyheatingcurrentyear-2 | The energy consumption when heating for current year February |
|
|
| energyheatingcurrentyear-3 | The energy consumption when heating for current year March |
|
|
| energyheatingcurrentyear-4 | The energy consumption when heating for current year April |
|
|
| energyheatingcurrentyear-5 | The energy consumption when heating for current year May |
|
|
| energyheatingcurrentyear-6 | The energy consumption when heating for current year June |
|
|
| energyheatingcurrentyear-7 | The energy consumption when heating for current year July |
|
|
| energyheatingcurrentyear-8 | The energy consumption when heating for current year August |
|
|
| energyheatingcurrentyear-9 | The energy consumption when heating for current year September |
|
|
| energyheatingcurrentyear-10 | The energy consumption when heating for current year October |
|
|
| energyheatingcurrentyear-11 | The energy consumption when heating for current year November |
|
|
| energyheatingcurrentyear-12 | The energy consumption when heating for current year December |
|
|
| energycoolingtoday | The energy consumption when cooling for today |
|
|
| energycoolingthisweek | The energy consumption when cooling for this week |
|
|
| energycoolinglastweek | The energy consumption when cooling for last week |
|
|
| energycoolingcurrentyear-1 | The energy consumption when cooling for current year January |
|
|
| energycoolingcurrentyear-2 | The energy consumption when cooling for current year February |
|
|
| energycoolingcurrentyear-3 | The energy consumption when cooling for current year March |
|
|
| energycoolingcurrentyear-4 | The energy consumption when cooling for current year April |
|
|
| energycoolingcurrentyear-5 | The energy consumption when cooling for current year May |
|
|
| energycoolingcurrentyear-6 | The energy consumption when cooling for current year June |
|
|
| energycoolingcurrentyear-7 | The energy consumption when cooling for current year July |
|
|
| energycoolingcurrentyear-8 | The energy consumption when cooling for current year August |
|
|
| energycoolingcurrentyear-9 | The energy consumption when cooling for current year September |
|
|
| energycoolingcurrentyear-10 | The energy consumption when cooling for current year October |
|
|
| energycoolingcurrentyear-11 | The energy consumption when cooling for current year November |
|
|
| energycoolingcurrentyear-12 | The energy consumption when cooling for current year December |
|
|
| demandcontrolmode | The demand control mode (`OFF`, `AUTO`, `MANUAL`, `SCHEDULED`) |
|
|
| demandcontrolmaxpower | The maximum power when in `MANUAL` mode. Values between 40 and 100 are accepted in an increment of 5. In `SCHEDULED` demand control mode, this channel will be updated with the calculated maximum power based on the current active schedule. |
|
|
| demandcontrolschedule | A JSON string that contains the scheduled demand control settings. See below. |
|
|
|
|
For the BRP15B61:
|
|
|
|
| Channel Name | Description |
|
|
| --------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
|
| power | Turns the power on/off for the air conditioning unit. |
|
|
| settemp | The temperature set for the air conditioning unit. |
|
|
| indoortemp | The indoor temperature as measured by the unit. |
|
|
| outdoortemp | The outdoor temperature as measured by the external part of the air conditioning system. May not be available when unit is off. |
|
|
| mode | The mode set for the unit (AUTO, DEHUMIDIFIER, COLD, HEAT, FAN) |
|
|
| homekitmode | A mode that is compatible with homekit/alexa/google home (off, auto, heat, cool) |
|
|
| airbasefanspeed | The fan speed set for the unit (AUTO, AIRSIDE, LEVEL_1, LEVEL_2, LEVEL_3, LEVEL_4, LEVEL_5, AUTO_LEVEL_1, AUTO_LEVEL_2, AUTO_LEVEL_3, AUTO_LEVEL_4, AUTO_LEVEL_5) |
|
|
| zone1 | Turns zone 1 on/off for the air conditioning unit (if a zone controller is installed.) |
|
|
| zone2 | Turns zone 2 on/off for the air conditioning unit. |
|
|
| zone3 | Turns zone 3 on/off for the air conditioning unit. |
|
|
| zone4 | Turns zone 4 on/off for the air conditioning unit. |
|
|
| zone5 | Turns zone 5 on/off for the air conditioning unit. |
|
|
| zone6 | Turns zone 6 on/off for the air conditioning unit. |
|
|
| zone7 | Turns zone 7 on/off for the air conditioning unit. |
|
|
| zone8 | Turns zone 8 on/off for the air conditioning unit. |
|
|
|
|
## Demand Control
|
|
|
|
Some units have a _demand control_ feature to limit the maximum power usage to a certain percentage.
|
|
This is set through the `demandcontrolmode` channel which accepts `OFF`, `MANUAL`, `SCHEDULED`, or `AUTO`.
|
|
|
|
When changing the mode from `MANUAL` to another mode, the maximum power setting will be saved in the Binding's memory and restored when switching the mode back to `MANUAL`.
|
|
Equally, when changing the mode from `SCHEDULED` to another mode, the current schedule will be saved in the Binding's memory and restored when switching the mode back to `SCHEDULED`.
|
|
|
|
### Manual Demand Control
|
|
|
|
Manual demand control requires setting the `demandcontrolmaxpower` channel to the desired limit.
|
|
The unit accepts values between 40% and 100% in increments of 5.
|
|
|
|
Sending a command to the `demandcontrolmaxpower` channel will automatically switch the demand control mode to `MANUAL`.
|
|
|
|
### Scheduled Demand Control
|
|
|
|
It is possible to set the demand control power limit based on day of the week and time of day schedules.
|
|
When the unit is in scheduled demand control mode, the binding provides the current schedule through the `demandcontrolschedule` channel.
|
|
|
|
In `SCHEDULED`, the `demandcontrolmaxpower` channel will provide the _current_ maximum power in effect, as defined within the schedule.
|
|
This information is not provided by the unit itself.
|
|
It is calculated by the binding based on the current schedule.
|
|
Therefore, it is important to ensure that openHAB's local time is in sync with the unit's date/time.
|
|
|
|
The schedule and associated max power settings can be set by sending a command to the `demandcontrolschedule` channel.
|
|
When doing so, the demand control mode will automatically change to `SCHEDULED`, if it wasn't already in that mode.
|
|
|
|
The schedule is specified in a JSON string in the following format:
|
|
|
|
```json
|
|
{
|
|
"monday": [
|
|
{
|
|
"enabled": true,
|
|
"time": <minutes from midnight>,
|
|
"power": <power in percent>
|
|
}
|
|
],
|
|
"tuesday": [
|
|
// Schedule entries for Tuesday
|
|
],
|
|
"wednesday": [
|
|
|
|
],
|
|
// more days up to Sunday
|
|
"sunday": [
|
|
|
|
]
|
|
}
|
|
```
|
|
|
|
Concrete example:
|
|
|
|
The JSON format doesn't actually support comments. They are provided for clarity.
|
|
|
|
```json
|
|
{
|
|
"monday": [
|
|
{
|
|
"enabled": true,
|
|
"time": 480, // 8 am
|
|
"power": 80
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 600, // 10 am
|
|
"power": 100
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 960, // 4pm
|
|
"power": 50
|
|
}
|
|
],
|
|
"tuesday": [
|
|
{
|
|
"enabled": true,
|
|
"time": 480, // 8 am
|
|
"power": 80
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 600, // 10 am
|
|
"power": 100
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 960, // 4pm
|
|
"power": 50
|
|
}
|
|
],
|
|
"wednesday": [
|
|
{
|
|
"enabled": true,
|
|
"time": 480, // 8 am
|
|
"power": 80
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 600, // 10 am
|
|
"power": 100
|
|
},
|
|
{
|
|
"enabled": true,
|
|
"time": 960, // 4pm
|
|
"power": 50
|
|
}
|
|
],
|
|
"thursday": [
|
|
{
|
|
"enabled": true,
|
|
"time": 480, // 8 am
|
|
"power": 100
|
|
}
|
|
]
|
|
// omitted days mean that they contain no schedules
|
|
}
|
|
```
|
|
|
|
Note:
|
|
|
|
- Each day can have up to 4 schedule entries
|
|
- `enabled` means whether this schedule element is enabled.
|
|
- `time` is the start time of the schedule, expressed in number of minutes from midnight.
|
|
- `power` a value of zero means demand power is disabled at the time defined by the `time` element.
|
|
- When there are no schedules defined for the current day/time, it is believed that the settings from the previous schedule will apply, bearing in mind that it is a weekly recurring schedule.
|
|
This is ultimately determined by the logic in the unit itself, and not controlled by the Binding.
|
|
|
|
## Full Example
|
|
|
|
daikin.things:
|
|
|
|
```java
|
|
// for BRP069B41 or BRP072A42
|
|
daikin:ac_unit:living_room_ac [ host="192.168.0.5" ]
|
|
// for BRP072C42
|
|
daikin:ac_unit:living_room_ac [ host="192.168.0.5", secure=true, uuid="xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx", key="xxxxxxxxxxxxx" ]
|
|
// for Airbase (BRP15B61)
|
|
daikin:airbase_ac_unit:living_room_ac [ host="192.168.0.5" ]
|
|
```
|
|
|
|
daikin.items:
|
|
|
|
```java
|
|
// for BRP069B41, BRP072A42 or BRP072C42
|
|
Switch DaikinACUnit_Power { channel="daikin:ac_unit:living_room_ac:power" }
|
|
Number:Temperature DaikinACUnit_SetPoint { channel="daikin:ac_unit:living_room_ac:settemp" }
|
|
String DaikinACUnit_Mode { channel="daikin:ac_unit:living_room_ac:mode" }
|
|
String DaikinACUnit_HomekitMode { channel="daikin:ac_unit:living_room_ac:homekitmode" }
|
|
String DaikinACUnit_Fan { channel="daikin:ac_unit:living_room_ac:fanspeed" }
|
|
String DaikinACUnit_Fan_Movement { channel="daikin:ac_unit:living_room_ac:fandir" }
|
|
Number:Temperature DaikinACUnit_IndoorTemperature { channel="daikin:ac_unit:living_room_ac:indoortemp" }
|
|
Number:Temperature DaikinACUnit_OutdoorTemperature { channel="daikin:ac_unit:living_room_ac:outdoortemp" }
|
|
// Demand control, when supported by the unit
|
|
String DaikinACUnit_DemandControl_Mode { channel="daikin:ac_unit:living_room_ac:demandcontrolmode" }
|
|
Dimmer DaikinACUnit_DemandControl_MaxPower { channel="daikin:ac_unit:living_room_ac:demandcontrolmaxpower" }
|
|
String DaikinACUnit_DemandControl_Schedule { channel="daikin:ac_unit:living_room_ac:demandcontrolschedule" }
|
|
|
|
// for Airbase (BRP15B61)
|
|
Switch DaikinACUnit_Power { channel="daikin:airbase_ac_unit:living_room_ac:power" }
|
|
Number:Temperature DaikinACUnit_SetPoint { channel="daikin:airbase_ac_unit:living_room_ac:settemp" }
|
|
String DaikinACUnit_Mode { channel="daikin:airbase_ac_unit:living_room_ac:mode" }
|
|
String DaikinACUnit_HomekitMode { channel="daikin:airbase_ac_unit:living_room_ac:homekitmode" }
|
|
String DaikinACUnit_Fan { channel="daikin:airbase_ac_unit:living_room_ac:fanspeed" }
|
|
Number:Temperature DaikinACUnit_IndoorTemperature { channel="daikin:airbase_ac_unit:living_room_ac:indoortemp" }
|
|
Number:Temperature DaikinACUnit_OutdoorTemperature { channel="daikin:airbase_ac_unit:living_room_ac:outdoortemp" }
|
|
Switch DaikinACUnit_Zone1 { channel="daikin:airbase_ac_unit:living_room_ac:zone1" }
|
|
Switch DaikinACUnit_Zone2 { channel="daikin:airbase_ac_unit:living_room_ac:zone2" }
|
|
Switch DaikinACUnit_Zone3 { channel="daikin:airbase_ac_unit:living_room_ac:zone3" }
|
|
Switch DaikinACUnit_Zone4 { channel="daikin:airbase_ac_unit:living_room_ac:zone4" }
|
|
Switch DaikinACUnit_Zone5 { channel="daikin:airbase_ac_unit:living_room_ac:zone5" }
|
|
Switch DaikinACUnit_Zone6 { channel="daikin:airbase_ac_unit:living_room_ac:zone6" }
|
|
Switch DaikinACUnit_Zone7 { channel="daikin:airbase_ac_unit:living_room_ac:zone7" }
|
|
Switch DaikinACUnit_Zone8 { channel="daikin:airbase_ac_unit:living_room_ac:zone8" }
|
|
```
|
|
|
|
daikin.sitemap:
|
|
|
|
```perl
|
|
// for BRP069B41, BRP072A42 or BRP072C42
|
|
Switch item=DaikinACUnit_Power
|
|
Setpoint item=DaikinACUnit_SetPoint visibility=[DaikinACUnit_Power==ON]
|
|
Selection item=DaikinACUnit_Mode mappings=["AUTO"="Auto", "DEHUMIDIFIER"="Dehumidifier", "COLD"="Cold", "HEAT"="Heat", "FAN"="Fan"] visibility=[DaikinACUnit_Power==ON]
|
|
Selection item=DaikinACUnit_Fan mappings=["AUTO"="Auto", "SILENCE"="Silence", "LEVEL_1"="Level 1", "LEVEL_2"="Level 2", "LEVEL_3"="Level 3", "LEVEL_4"="Level 4", "LEVEL_5"="Level 5"] visibility=[DaikinACUnit_Power==ON]
|
|
Selection item=DaikinACUnit_Fan_Movement mappings=["STOPPED"="Stopped", "VERTICAL"="Vertical", "HORIZONTAL"="Horizontal", "VERTICAL_AND_HORIZONTAL"="Vertical and Horizontal"] visibility=[DaikinACUnit_Power==ON]
|
|
Text item=DaikinACUnit_IndoorTemperature
|
|
Text item=DaikinACUnit_OutdoorTemperature
|
|
|
|
// for Airbase (BRP15B61)
|
|
Switch item=DaikinACUnit_Power
|
|
Setpoint item=DaikinACUnit_SetPoint visibility=[DaikinACUnit_Power==ON]
|
|
Selection item=DaikinACUnit_Mode mappings=["AUTO"="Auto", "DEHUMIDIFIER"="Dehumidifier", "COLD"="Cold", "HEAT"="Heat", "FAN"="Fan"] visibility=[DaikinACUnit_Power==ON]
|
|
Selection item=DaikinACUnit_Fan visibility=[DaikinACUnit_Power==ON]
|
|
Text item=DaikinACUnit_IndoorTemperature
|
|
Text item=DaikinACUnit_OutdoorTemperature
|
|
Switch item=DaikinACUnit_Zone1 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone2 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone3 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone4 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone5 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone6 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone7 visibility=[DaikinACUnit_Power==ON]
|
|
Switch item=DaikinACUnit_Zone8 visibility=[DaikinACUnit_Power==ON]
|
|
```
|