* ReverseEngineerProtocol Signed-off-by: Martin Grześlowski <martin.grzeslowski@gmail.com>
2.8 KiB
ReverseEngineerProtocol CLI Documentation
This documentation provides instructions on how to use the ReverseEngineerProtocol CLI program to reverse engineer the proprietary Salus protocol.
How to Run
To execute the CLI program, run the main
method from the ReverseEngineerProtocol
class. You can either run it directly from an IDE or use the java
command. The program requires three parameters: email
, password
, and the Salus backend type (AwsSalusApi
or HttpSalusApi
).
Running from an IDE
- Open the project in your IDE.
- Navigate to the
ReverseEngineerProtocol
class. - Run the
main
method, passing in the required parameters.
Running from the Command Line
java -cp <your-compiled-class-path> ReverseEngineerProtocol <email> <password> <backendType>
Replace <your-compiled-class-path>
with the path to your compiled classes, and <email>
, <password>
, and <backendType>
with your actual credentials and backend type.
Methods
findDevices
Finds and lists all devices associated with your Salus cloud account.
Usage:
./ReverseEngineerProtocol <email> <password> <backendType> findDevices
findDeviceProperties <dsn>
Retrieves all properties for the device with the given Device Serial Number (DSN).
Parameters:
<dsn>
: The Device Serial Number of the target device.
Usage:
./ReverseEngineerProtocol <email> <password> <backendType> findDeviceProperties <dsn>
findDeltaInProperties <dsn>
Initializes by loading all properties from the given device, then filters out the properties that have changed or remained unchanged. This method is useful for identifying which property corresponds to a specific value or state.
Parameters:
<dsn>
: The Device Serial Number of the target device.
Example Use Case:
To find which property stores the "running" state of a device:
- Run
findDeltaInProperties <dsn>
. - Filter out properties that have changed (this can be done multiple times).
- Trigger the device to change state (e.g., set the temperature higher than the current one to make the device run).
- Filter out properties that have not changed.
- Repeat steps 2-4 until the desired property is identified.
Usage:
./ReverseEngineerProtocol <email> <password> <backendType> findDeltaInProperties <dsn>
monitorProperty <dsn> <propertyName> <sleep>
Monitors and retrieves the value of a specific property from a given device at specified intervals.
Parameters:
<dsn>
: The Device Serial Number of the target device.<propertyName>
: The name of the property to monitor.<sleep>
: (optional; default 1) The sleep interval (in seconds) between each check.
Usage: