# SEMSPortal Binding
|
|
|
|
This binding can help you include statistics of your SEMS / GoodWe solar panel installation into openHAB.
|
|
It is a read-only connection that maps collected parameters to openHAB channels.
|
|
It provides current, day, month and total yields, as well as some income statistics if you have configured these in the SEMS portal.
|
|
It requires a power station that is connected through the internet to the SEMS portal.
|
|
|
|
## Supported Things
|
|
|
|
This binding provides two Thing types: a bridge to the SEMS Portal, and the Power Stations which are found at the Portal.
|
|
The Portal (``semsportal:portal``) represents your account in the SEMS portal.
|
|
The Power Station (``semsportal:station``) is an installation of a Power Station or inverter that reports to the SEMS portal and is available to your account.
|
|
|
|
## Discovery
|
|
|
|
Once you have configured a Portal Bridge, the binding will discover all Power Stations that are available to this account.
|
|
You can trigger discovery in the add new Thing section of openHAB.
|
|
Select the SEMS binding and press the Scan button.
|
|
The discovered Power Stations will appear as new Things.
|
|
|
|
## Thing Configuration
|
|
|
|
The configuration of the Portal Thing (Bridge) is pretty straight forward.
|
|
You need to have your power station set up in the SEMS portal, and you need to have an account that is allowed to view the power station data.
|
|
You should log in at least once in the portal with this account to activate it.
|
|
The Portal needs the username and password to connect and retrieve the data.
|
|
You can configure the update frequency between 1 and 60 minutes.
|
|
The default is 5 minutes.
|
|
|
|
Power Stations have no settings and will be auto discovered when you add a Portal Bridge.
|
|
|
|
If you prefer manual configuration of things in thing files, you need to supply the power station UUID.
|
|
It can be found in the SEMS portal URL after you have logged in.
|
|
The URL will look like this:
|
|
|
|
```text
|
|
https://www.semsportal.com/PowerStation/PowerStatusSnMin/xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
|
|
```
|
|
|
|
Where the part after the last / character is the UUID to be used.
|
|
|
|
Example portal configuration with a station:
|
|
|
|
```java
|
|
Bridge semsportal:portal:myPortal [ username="my@username.com", password="MyPassword" ] {
|
|
station solarPanels "Solar Panels" [ stationUUID="xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx" ]
|
|
}
|
|
```
|
|
|
|
## Channels
|
|
|
|
The Portal(Bridge) has no channels.
|
|
The Power Station Thing has the following channels:
|
|
|
|
| channel | type | description |
|
|
| ------------- | ------------- | ---------------------------------------------------------------------------------------------------------- |
|
|
| lastUpdate | DateTime | Last time the powerStation sent information to the portal |
|
|
| currentOutput | Number:Power | The current output of the powerStation in Watt |
|
|
| todayTotal | Number:Energy | Todays total generation of the station in kWh |
|
|
| monthTotal | Number:Energy | This month's total generation of the station in kWh |
|
|
| overallTotal | Number:Energy | The total generation of the station since installation, in kWh |
|
|
| todayIncome | Number | Todays income as reported by the portal, if you have configured the power rates of your energy provider |
|
|
| totalIncome | Number | The total income as reported by the portal, if you have configured the power rates of your energy provider |
|
|
|
|
## Parameters
|
|
|
|
The Power Station Thing has no configuration parameters when auto discovered.
|
|
When using thing files you need to provide the station UUID.
|
|
|
|
| Parameter | Required? | Description |
|
|
| ----------- | :-------: | -------------------------------------------------------------------------------- |
|
|
| stationUUID | X | UUID of the station. Can be found on the SEMS portal URL (see description above) |
|
|
|
|
The Bridge has the following configuration parameters:
|
|
|
|
| Parameter | Required? | Description |
|
|
| --------- | :-------: | ----------------------------------------------------------------------------------------------------- |
|
|
| username | X | Account name (email address) at the SEMS portal. Account must have been used at least once to log in. |
|
|
| password | X | Password of the SEMS portal |
|
|
| interval | | Number of minutes between two updates. Between 1 and 60 minutes, defaults to 5 minutes |
|
|
|
|
## Credits
|
|
|
|