mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-10 23:22:02 +01:00
caf71f72e6
Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
87 lines
5.8 KiB
Markdown
87 lines
5.8 KiB
Markdown
# EchonetLite Binding
|
|
|
|
This binding supports devices that make use of the [Echonet Lite specification](https://echonet.jp/spec_v113_lite_en/).
|
|
|
|
## Supported Things
|
|
|
|
- Mitsubishi Electric MAC-568IF-E Wi-Fi interface (common on most Mitsubishi Heat Pumps).
|
|
|
|
## Discovery
|
|
|
|
Discovery is supported using UDP Multicast.
|
|
When running over Wi-Fi it is advisable to run openHAB on the same network as the Echonet Lite devices.
|
|
Multicast traffic doesn't easily route over multiple networks and will often be dropped.
|
|
Discovery is handled via the Echonet Lite bridge, which contains the configuration of the multicast address used for discovery and asynchronous device notifications along with the port.
|
|
It is unlikely that this configuration will require changing.
|
|
|
|
## Bridge Configuration
|
|
|
|
The bridge configuration defaults should be applicable in most scenarios.
|
|
If device discovery is not working, this is most likely caused by the inability to receive multicast traffic from the device nodes.
|
|
|
|
- **port**: Port used for messaging both to and from device nodes, defaults to 3610.
|
|
- **multicastAddress**: Multicast address used to discover device nodes and to receive asynchronous notifications from devices.
|
|
|
|
## Thing Configuration
|
|
|
|
- **hostname**: Hostname or IP address of the device node.
|
|
- **port**: Port used to communicate with the device.
|
|
- **groupCode**: Group code as specified in "APPENDIX Detailed Requirements for ECHONET Device objects" (<https://echonet.jp/spec_object_rp1_en/>).
|
|
For Air Conditioners the value is '1'.
|
|
- **classCode**: Class code for the device, see **groupCode** for reference information.
|
|
The value for Home Air Conditioners is '48' (0x30).
|
|
- **instance**: Instance identifier if multiple instances are running on the same IP address.
|
|
Typically, this value will be '1'.
|
|
- **pollIntervalMs**: Interval between polls of the device for its current status.
|
|
If multicast is not working this will determine the latency at which changes made directly on the device will be propagated back to openHAB, default is 30 000ms.
|
|
- **retryTimeoutMs**: Length of time the bridge will wait before resubmitting a request, default is 2 000ms.
|
|
|
|
Because the binding uses UDP, packets can be lost on the network, so retries are necessary.
|
|
Testing has shown that 2 000ms is a reasonable default that allows for timely retries without rejecting slow, but legitimate responses.
|
|
|
|
## Channels
|
|
|
|
Channels are derived from the Echonet Lite specification and vary from device to device depending on capabilities.
|
|
The full set of potential channels is available from "APPENDIX Detailed Requirements for ECHONET Device objects" (<https://echonet.jp/spec_object_rp1_en/>)
|
|
|
|
The channels currently implemented are:
|
|
|
|
| Channel | Data Type | Description |
|
|
|------------------------------------|-----------|-------------------------------------------------------------------------|
|
|
| operationStatus | Switch | Switch On/Off the device |
|
|
| installationLocation | String | Installation location (option) |
|
|
| standardVersionInformation | String | Standard Version Information |
|
|
| identificationNumber | String | Unique id for device (used by auto discovery for the thingId) |
|
|
| manufacturerFaultCode | String | Manufacturer Fault Code |
|
|
| faultStatus | Switch | Fault Status |
|
|
| faultDescription | String | Fault Description |
|
|
| manufacturerCode | String | Manufacturer Code |
|
|
| businessFacilityCode | String | Business Facility Code |
|
|
| powerSavingOperationSetting | Switch | Controls whether the unit is in power saving operation or not |
|
|
| cumulativeOperatingTime | Number | Cumulative Operating Time |
|
|
| airFlowRate | String | Air Flow Rate |
|
|
| automaticControlOfAirFlowDirection | String | The type of automatic control applied to the air flow direction, if any |
|
|
| automaticSwingOfAirFlow | String | Automatic Swing Of Air Flow |
|
|
| airFlowDirectionVertical | String | Air Flow Direction Vertical |
|
|
| airFlowDirectionHorizontal | String | Air Flow Direction Horizontal |
|
|
| operationMode | String | The current mode for the Home AC unit (heating, cooling, etc.) |
|
|
| setTemperature | Number | Desired target room temperature |
|
|
| measuredRoomTemperature | Number | Measured Room Temperature |
|
|
| measuredOutdoorTemperature | Number | Measured Outdoor Temperature |
|
|
|
|
## Full Example
|
|
|
|
### Things
|
|
|
|
```java
|
|
Bridge echonetlite:bridge:1 [port="3610", multicastAddress="224.0.23.0"] {
|
|
Thing device HeatPump_Bedroom1 "HeatPump Bedroom 1" @ "Bedroom 1" [hostname="192.168.0.55", port="3610", groupCode="1", classCode="48", instance="1", pollIntervalMs="30000", retryTimeoutMs="2000"]
|
|
}
|
|
```
|
|
|
|
### Items
|
|
|
|
```java
|
|
Switch HeatPumpBedroom1_OperationStatus "HeatPump Bedroom1 Operation Status" {channel="echonetlite:device:1:HeatPump_Bedroom1:operationStatus"}
|
|
```
|