# GCE Binding
|
|
|
|
This binding aims to handle various GCE Electronics equipments.
|
|
IPX800 is a 8 relay webserver from gce-electronics with a lot of possibilities:
|
|
|
|
* 8 Digital Input
|
|
* 8 Relay (250V / 10A / channel)
|
|
* 4 Analog Input
|
|
* 8 Counters
|
|
* Ability to cascade up to 3 extensions for a total of 32 inputs / 32 relay
|
|
|
|
Each IPX800 connected to openHAB must be configured with the setting 'Send data on status changed' on the website in M2M > TCP client.
|
|
|
|
To make it simple, IPX800 is a simple device that drives output and retrieves input.
|
|
On input we generally connect push buttons (for instance house switchs), on ouputs we can connect light bulbs for instance.
|
|
|
|
Features of the binding:
|
|
|
|
* Multi ipx support
|
|
* Direct TCP connection
|
|
* Auto reconnect
|
|
* Simple clic/Long press
|
|
* Pulse mode support
|
|
|
|
## Binding Configuration
|
|
|
|
There is no configuration at binding level.
|
|
|
|
|
|
## Thing Configuration
|
|
|
|
The IPX800v3 (ID : 'ipx800v3') accepts the following configuration parameters :
|
|
|
|
| Property | Default | Required | Description |
|
|
|---------------------|---------|----------|-----------------------------|
|
|
| hostname | | Yes | IP address or hostname. |
|
|
| portNumber | 9870 | No | TCP client connection port. |
|
|
| pullInterval* | 5000 | No | Refresh interval (in ms) |
|
|
|
|
The binding will query periodically the 'globalstatus.xml' page of the IPX to get fresh informations.
|
|
This is especially usefull for Analog inputs and Counter as modification of these values on PLC side does not trigger any M2M message.
|
|
|
|
The thing provides four groups of channels.
|
|
|
|
### Digital Inputs
|
|
|
|
This represents the inputs of the PLC. Each can be open or closed.
|
|
They are usually commuted by physical devices like pushbuttons, magnets...
|
|
|
|
#### Digital Input Channels (contacts)
|
|
|
|
Each input will have these associated channels:
|
|
|
|
| Group | Channel Name | Item Type | R/W | Description |
|
|
|----------|------------------------|-------------|-----|-----------------------------------------------------------------------------|
|
|
| contact | `portnumber` | Contact | R | Status of the actual port (OPEN, CLOSED) |
|
|
| contact | `portnumber`-duration | Number:Time | R | Updated when the port status changes to the duration of the previous state. |
|
|
|
|
Associated events:
|
|
|
|
| Channel Type ID | Options | Description | Conf Dependency |
|
|
|--------------------|-------------------|--------------------------------------------------|-----------------|
|
|
| `portnumber`-event | | Triggered on or after a port status change | |
|
|
| | PRESSED | Triggered when state changes from OPEN to CLOSED | |
|
|
| | RELEASED | Triggered when state changes from CLOSED to OPEN | |
|
|
| | LONG_PRESS | Triggered when RELEASED after a long period | longPressTime |
|
|
| | SHORT_PRESS | Triggered when RELEASED before a long period | longPressTime |
|
|
| | PULSE | Triggered during CLOSED state | pulsePeriod |
|
|
|
|
#### Configuration
|
|
|
|
| Property | Default | Unit | Description |
|
|
|-----------------|---------|------|---------------------------------------------------------------------------------|
|
|
| debouncePeriod | 0(*) | ms | Debounce time (ignores flappling within this time). No debounce is done if '0'. |
|
|
| longPressTime | 0(*) | ms | Delay before triggering long press event. Ignored if '0'. |
|
|
| pulsePeriod | 0(*) | ms | Period of pulse event triggering while the entry is closed. Ignored if '0'. |
|
|
| pulseTimeout | 0(*) | ms | Period of time after pulsing will be stopped. None if '0'. |
|
|
|
|
* Values below 100ms should be avoided as the JVM could skip them and proceed in the same time slice.
|
|
|
|
|
|
### Digital Outputs Channels (relays)
|
|
|
|
Each output will have these associated channels:
|
|
|
|
| Group | Channel Name | Item Type | R/W | Description |
|
|
|----------|------------------------|-------------|-----|-----------------------------------------------------------------------------|
|
|
| relay | `portnumber` | Switch | R/W | Status of the actual port (ON, OFF) |
|
|
| relay | `portnumber`-duration | Number:Time | R | Updated when the port status changes to the duration of the previous state. |
|
|
|
|
#### Configuration
|
|
|
|
| Property | Default | Description |
|
|
|-----------------|---------|--------------------------------------------------------------------------|
|
|
| pulse | false | If set, the output will be in pulse mode, releasing it after the contact |
|
|
|
|
### Counters Channels
|
|
|
|
Each counter will have these associated channels:
|
|
|
|
| Group | Channel Name | Item Type | R/W | Description |
|
|
|----------|--------------------------|-------------|-----|--------------------------------------------------------------------------------|
|
|
| counter | `counternumber` | Number | R | Actual value of the counter |
|
|
| counter | `counternumber`-duration | Number:Time | R | Updated when the counter status changes to the duration of the previous state. |
|
|
|
|
#### Configuration
|
|
|
|
This channel has no configuration setting.
|
|
|
|
### Analog Inputs Channels
|
|
|
|
Each analog port will have these associated channels:
|
|
|
|
| Group | Channel Name | Item Type | R/W | Description |
|
|
|--------|-----------------------|--------------------------|-----|-----------------------------------------------------------------------------|
|
|
| analog | `portnumber` | Number | R | Value of the port. |
|
|
| analog | `portnumber`-duration | Number:Time | R | Updated when the port status changes to the duration of the previous state. |
|
|
| analog | `portnumber`-voltage | Number:ElectricPotential | R | Electrical equivalency of the analogic value |
|
|
|
|
#### Configuration
|
|
|
|
| Property | Default | Description |
|
|
|------------|---------|-------------------------------------------------------------------------------------|
|
|
| hysteresis | 0 | If set, the channel will ignore status if change (+ or -) is less than hysteresis/2 |
|
|
|
|
|
|
## Rule Actions
|
|
|
|
Multiple actions are supported by this binding. In classic rules these are accessible as shown in the example below:
|
|
|
|
Getting ipxActions variable in scripts
|
|
|
|
```
|
|
val ipxActions = getActions("gce","gce:ipx800v3:43cc8d07")
|
|
if(null === ipxActions) {
|
|
logInfo("actions", "ipxActions not found, check thing ID")
|
|
return
|
|
} else {
|
|
// do something with sunActions
|
|
}
|
|
```
|
|
|
|
### resetCounter(counterId)
|
|
|
|
Resets the value of the given counter to 0.
|
|
|
|
* `counterId` (Integer) - id of the counter.
|
|
|
|
|
|
### reset(placeholder)
|
|
|
|
Restarts the PLC.
|
|
|
|
* `placeholder` (Integer) - This parameter is not used (can be null).
|
|
|
|
## Example
|
|
|
|
### Things
|
|
|
|
ipx800.things
|
|
|
|
```java
|
|
|
|
Thing gce:ipx800v3:ipx "IPX800" @ "diningroom" [hostname="192.168.0.144", portNumber=9870] {
|
|
Channels:
|
|
Type contact : contact#1 [ // Aimant Détection porte de garage ouverte
|
|
debouncePeriod=2500,
|
|
pulsePeriod=1000,
|
|
pulseTimeout=60000
|
|
]
|
|
Type contact : contact#2 [ // Aimant Détection porte de garage fermée
|
|
debouncePeriod=2500
|
|
]
|
|
Type relay : relay#8 [ // Actionneur porte de garage
|
|
pulse=true
|
|
]
|
|
}
|
|
```
|
|
|
|
ipx800.items
|
|
|
|
```java
|
|
|
|
Group gIPXInputs "Inputs" <input>
|
|
Contact input1 "Porte garage ouverte [%s]" <contact> (gIPXInputs) {channel="gce:ipx800v3:ipx:contact#1"}
|
|
Contact input2 "Porte garage fermée [%s]" <contact> (gIPXInputs) {channel="gce:ipx800v3:ipx:contact#2"}
|
|
|
|
Group gIPXOutputs "Outputs" <output>
|
|
Switch output3 "Chaudière" <furnace> (gIPXOutputs) {channel="gce:ipx800v3:ipx:relay#3"}
|
|
Switch output4 "Lumière Porche" <light> (gIPXOutputs) {channel="gce:ipx800v3:ipx:relay#4"}
|
|
|
|
```
|