* [modbus] add support for rtu encoded over tcp * [modbus] move classes to openhab/jamod * [modbus] spotless * [modbus] revert EndpointPoolConfiguration * [modbus] remove virtual serial * [modbus] resolve dependencies * [modbus.studer] add support for RTU over TCP bridge Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
147 lines
8.4 KiB
Markdown
147 lines
8.4 KiB
Markdown
# Studer
|
|
|
|
This extension adds support for the Studer protocol.
|
|
|
|
Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland
|
|
|
|
For a list of certified products see this page: https://www.studer-innotec.com/
|
|
|
|
## Supported Things
|
|
|
|
This bundle adds the following thing type to the Modbus binding.
|
|
Note, that the things will show up under the Modbus binding.
|
|
|
|
| Thing Type IDs | Description | Picture |
|
|
|----------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------|
|
|
| bsp | For BSP that offer a highly precise measuring for Xtender, VarioTrack and VarioString systems | ![BSP](doc/bsp.png) |
|
|
| xtender | For the Xtender models for system capacities from 0.5kVA to 72kVA that allow for the optimal use of available energy | ![Xtender](doc/xtender.png) |
|
|
| variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp | ![VarioTrack](doc/variotrack.png) |
|
|
| variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 | ![VarioString](doc/variostring.png) |
|
|
|
|
|
|
## Thing Configuration
|
|
|
|
You need first to set up a Serial Modbus bridge according to the Modbus documentation.
|
|
Things in this extension will use the selected bridge to connect to the device.
|
|
|
|
For defining a thing textually, you have to find out the start address of the model block and the length of it.
|
|
While the length is usually fixed, the address is not.
|
|
Please refer to your device's vendor documentation how model blocks are laid for your equipment.
|
|
|
|
The following parameters are valid for all thing types:
|
|
|
|
| Parameter | Type | Required | Default if omitted | Description |
|
|
|-----------|---------|----------|-------------------------|----------------------------------------------------------------------------|
|
|
| address | integer | yes | `first slave of device` | Address of slave |
|
|
| refresh | integer | yes | 5 | Poll interval in seconds. Increase this if you encounter connection errors |
|
|
|
|
## Channels
|
|
|
|
The following Channels, and their associated channel types are shown below divided by device.
|
|
|
|
#### BSP
|
|
|
|
All channels read for a BSP device
|
|
|
|
| Channel | Type | Description |
|
|
| ------------------ | ------------------------ | --------------------- |
|
|
| power | Number:Power | Power |
|
|
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
|
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
|
| stateOfCharge | Number:Dimensionless | State of Charge |
|
|
| batteryTemperature | Number:Temperature | Battery temperature |
|
|
|
|
#### Xtender
|
|
|
|
All channels read for a Xtender device
|
|
|
|
| Channel | Type | Description |
|
|
| ----------------- | ------------------------ | ----------------------- |
|
|
| inputVoltage | Number:ElectricPotential | Input voltage |
|
|
| inputCurrent | Number:ElectricCurrent | Input current |
|
|
| inputActivePower | Number:Power | Input active power |
|
|
| inputFrequency | Number:Frequency | Input frequency |
|
|
| outputVoltage | Number:ElectricPotential | Output voltage |
|
|
| outputCurrent | Number:ElectricCurrent | Output current |
|
|
| outputActivePower | Number:Power | Output active power |
|
|
| outputFrequency | Number:Frequency | Output frequency |
|
|
| operatingState | String | Operating state |
|
|
| stateInverter | String | State of the inverter |
|
|
|
|
#### VarioTrack
|
|
|
|
All channels read for a VarioTrack device
|
|
|
|
| Channel | Type | Description |
|
|
| -------------------- | ------------------------ | ----------------------------------------- |
|
|
| modelVarioTrack | String | Model of VarioTrack |
|
|
| voltagePVGenerator | Number:ElectricPotential | Voltage of the PV generator |
|
|
| powerPVGenerator | Number:Power | Power of the PV generator |
|
|
| productionCurrentDay | Number:Energy | Production in (kWh) for the current day |
|
|
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
|
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
|
| operatingMode | String | Operating mode |
|
|
| stateVarioTrack | String | State of the VarioTrack |
|
|
|
|
#### VarioString
|
|
|
|
All channels read for a VarioString device
|
|
|
|
| Channel | Type | Description |
|
|
| ----------------------- | ------------------------ | --------------------------------------------- |
|
|
| PVVoltage | Number:ElectricPotential | PV voltage |
|
|
| PVCurrent | Number:ElectricCurrent | PV current |
|
|
| PVPower | Number:Power | PV power |
|
|
| ProductionPVCurrentDay | Number:Energy | Production PV in (kWh) for the current day |
|
|
| PV1Voltage | Number:ElectricPotential | PV1 voltage |
|
|
| PV1Current | Number:ElectricCurrent | PV1 current |
|
|
| PV1Power | Number:Power | PV1 power |
|
|
| ProductionPV1CurrentDay | Number:Energy | Production PV1 in (kWh) for the current day |
|
|
| PV2Voltage | Number:ElectricPotential | PV2 voltage |
|
|
| PV2Current | Number:ElectricCurrent | PV2 current |
|
|
| PV2Power | Number:Power | PV2 power |
|
|
| ProductionPV2CurrentDay | Number:Energy | Production PV2 in (kWh) for the current day |
|
|
| batteryVoltage | Number:ElectricPotential | Battery voltage |
|
|
| batteryCurrent | Number:ElectricCurrent | Battery current |
|
|
| PVMode | String | PV operating mode |
|
|
| PV1Mode | String | PV1 operating mode |
|
|
| PV2Mode | String | PV2 operating mode |
|
|
| stateVarioString | String | State of the VarioString |
|
|
|
|
## Example
|
|
|
|
### Thing Configuration
|
|
|
|
```
|
|
Bridge modbus:serial:bridge [port="/dev/ttyUSB0",baud=9600,dataBits=8,parity="even",stopBits="1.0",encoding="rtu"]
|
|
..or..
|
|
Bridge modbus:tcp:bridge [host="192.168.178.56", port=502, rtuEncoded=true]
|
|
|
|
...
|
|
|
|
Thing modbus:xtender:bridge:xtenderdevice "Xtender" (modbus:serial:modbusbridge) [ slaveAddress=10, refresh=5 ]
|
|
```
|
|
|
|
Note: Make sure that refresh and slave address are numerical, without quotes.
|
|
|
|
### Item Configuration
|
|
|
|
```
|
|
Number XtenderStuderThing_InputVoltage "Input Voltage [%.2f %unit%]"
|
|
{channel="modbus:xtender:bridge:xtenderdevice:inputVoltage"}
|
|
|
|
Number XtenderStuderThing_InputCurrent "Input Current [%.2f %unit%]" {channel="modbus:xtender:bridge:xtenderdevice:inputCurrent"}
|
|
|
|
String XtenderStuderThing_StateInverter "State: [%s]" {channel="modbus:xtender:bridge:xtenderdevice:stateInverter"}
|
|
```
|
|
|
|
### Sitemap Configuration
|
|
|
|
```
|
|
Text item=XtenderStuderThing_InputVoltage
|
|
Text item=XtenderStuderThing_InputCurrent
|
|
Text item=XtenderStuderThing_StateInverter
|
|
|
|
Chart item=XtenderStuderThing_InputVoltage period=D refresh=600000
|
|
Chart item=XtenderStuderThing_InputCurrent period=D refresh=30000
|
|
``` |