# Solarman Logger Binding
|
|
|
|
Binding used to communicate with Solarman (IGEN-Tech) v5 based solar inverter data loggers in direct-mode over the local network.
|
|
More information about the different types of stick loggers is available on the [Solarman](https://www.solarmanpv.com/products/data-logger/stick-logger/) site.
|
|
|
|
These data loggers are used by inverters from a lot of manufacturers, just to name a few:
|
|
|
|
- Deye
|
|
- Sofar
|
|
- Solis
|
|
- ZCS Azzurro
|
|
- KStar
|
|
|
|
## Supported Things
|
|
|
|
The `solarman:logger` thing supports reading data from a Solarman LSW-3 Stick Logger (it might also work with LSE-3 and maybe others) when connected to a supported inverter.
|
|
|
|
It was tested on a SUN-12K-SG04LP3-EU only, but because the implementation uses the inverter definitions created as part of Stephan Joubert's Home Assistant plugin it **might** work with the other inverters supported by the plugin.
|
|
|
|
## Thing Configuration
|
|
|
|
To connect the logger you need the IP address of the logger and its serial number.
|
|
The IP address can be obtained from your router and the serial number can either be read from the label of the logger, or by connecting to the logger with a browser (default user/pass: admin/admin) and getting it from the Status page.
|
|
*Please note* that you need the "Device serial number" from the "Device information" section, not the "Inverter serial number".
|
|
|
|
### `logger` Thing Configuration
|
|
|
|
| Name | Type | Description | Default | Required | Advanced |
|
|
|--------------------|---------|--------------------------------------------------------|---------|----------|----------|
|
|
| hostname | text | Hostname or IP address of the Solarman logger | N/A | yes | no |
|
|
| serialNumber | text | Serial number of the Solarman logger | N/A | yes | no |
|
|
| inverterType | text | The type of inverter connected to the logger | N/A | yes | no |
|
|
| port | integer | Port of the Solarman logger | 8899 | no | yes |
|
|
| refreshInterval | integer | Interval the device is polled in sec. | 60 | no | yes |
|
|
| additionalRequests | text | Additional requests besides the ones in the definition | N/A | no | yes |
|
|
|
|
The `inverterType` parameter governs what registers the binding will read from the logger and what channels it will expose.
|
|
|
|
Possible values:
|
|
|
|
| Inverter Type | Inverters supported | Notes |
|
|
|----------------------|---------------------------------------------------|------------------------------------------------------------------|
|
|
| deye_hybrid | DEYE/Sunsynk/SolArk Hybrid inverters | used when no lookup specified |
|
|
| deye_sg04lp3 | DEYE/Sunsynk/SolArk Hybrid 8/12K-SG04LP3 | e.g. 12K-SG04LP3-EU |
|
|
| deye_string | DEYE/Sunsynk/SolArk String inverters | e.g. SUN-4/5/6/7/8/10/12K-G03 Plus |
|
|
| deye_2mppt | DEYE Microinverter with 2 MPPT Trackers | e.g. SUN600G3-EU-230 / SUN800G3-EU-230 / SUN1000G3-EU-230 |
|
|
| deye_4mppt | DEYE Microinverter with 4 MPPT Trackers | e.g. SUN1300G3-EU-230 / SUN1600G3-EU-230 / SUN2000G3-EU-230 |
|
|
| sofar_lsw3 | SOFAR Inverters | |
|
|
| sofar_g3hyd | SOFAR Hybrid Three-Phase inverter | HYD 6000 or rebranded (three-phase), ex. ZCS Azzurro 3PH HYD-ZSS |
|
|
| sofar_hyd3k-6k-es | SOFAR Hybrid Single-Phase inverter | HYD 6000 or rebranded (single-phase), ex. ZCS Azzurro HYD-ZSS |
|
|
| solis_hybrid | SOLIS Hybrid inverter | |
|
|
| solid_1p8k-5g | SOLIS 1P8K-5G | |
|
|
| solis_3p-4g | SOLIS Three-Phase Inverter 4G Series | |
|
|
| solis_s6-gr1p | SOLIS Single-Phase Inverter S6-GR1P | |
|
|
| hyd-zss-hp-3k-6k | ZCS Azzurro Hybrid HP 3K-6K inverters | Rebranded Sofar models |
|
|
| kstar_hybrid | KSTAR Hybrid inverters | |
|
|
| sofar_wifikit | SOFAR WiFi Kit | |
|
|
| zcs_azzurro-ktl-v3 | ZCS Azzurro KTL-V3 inverters | ZCS Azzurro 3.3/4.4/5.5/6.6 KTL-V3 (rebranded Sofar KTLX-G3) |
|
|
|
|
The `additionalRequests` allows the user to specify additional address ranges to be polled. The format of the value is `mb_functioncode1:start1-end1, mb_functioncode2:start2-end2,...`
|
|
For example `"0x03:0x27D-0x27E"` will issue an additional read for Holding Registers between `0x27D` and `0x27E`.
|
|
|
|
This is useful when coupled with user defined channels, for example a thing definition like the one below will also read the register for the AC frequency on a Deye inverter, besides the ones pre-defined in the `deye_sg04lp3` inverter definition.
|
|
|
|
```java
|
|
Thing solarman:logger:local [ hostname="x.x.x.x", inverterType="deye_sg04lp3", serialNumber="1234567890", additionalRequests="0x03:0x27D-0x27E" ] {
|
|
Channels:
|
|
Type number : inverter-frequency [scale="0.01", uom="Hz", rule="3", registers="0x27E"]
|
|
}
|
|
```
|
|
|
|
**Please note** As of this writing inverter types besides the `deye_sg04lp3` were not tested to work.
|
|
If you have one of those inverters and it works, please drop me a message, if it doesn't work, please open an issue and I'll try to fix it.
|
|
|
|
## Channels
|
|
|
|
The list of channels is not static, it is generated dynamically based on the inverter type selected.
|
|
|
|
This is the list you get for the `deye_sg04lp3` inverter type:
|
|
|
|
| Channel | Type | Read/Write | Description |
|
|
|------------------------------------------|--------|--------------|-------------------------------------------------------|
|
|
| alert-alert | Number | R | Alert \[0x0229,0x022A,0x022B,0x022C,0x022D,0x022E\] |
|
|
| battery-battery-current | Number | R | Battery Current \[0x024F\] |
|
|
| battery-battery-power | Number | R | Battery Power \[0x024E\] |
|
|
| battery-battery-soc | Number | R | Battery SOC \[0x024C\] |
|
|
| battery-battery-temperature | Number | R | Battery Temperature \[0x024A\] |
|
|
| battery-battery-voltage | Number | R | Battery Voltage \[0x024B\] |
|
|
| battery-daily-battery-charge | Number | R | Daily Battery Charge \[0x0202\] |
|
|
| battery-daily-battery-discharge | Number | R | Daily Battery Discharge \[0x0203\] |
|
|
| battery-total-battery-charge | Number | R | Total Battery Charge \[0x0204,0x0205\] |
|
|
| battery-total-battery-discharge | Number | R | Total Battery Discharge \[0x0206,0x0207\] |
|
|
| battery-battery-absorption-v | Number | R | Battery Absorption V \[0x0064\] |
|
|
| battery-battery-empty-v | Number | R | Battery Empty V \[0x0066\] |
|
|
| battery-battery-equalization-v | Number | R | Battery Equalization V \[0x0063\] |
|
|
| battery-battery-float-v | Number | R | Battery Float V \[0x0065\] |
|
|
| battery-battery-capacity | Number | R | Battery Capacity \[0x0066\] |
|
|
| battery-battery-max-a-charge | Number | R | Battery Max A Charge \[0x006C\] |
|
|
| battery-battery-max-a-discharge | Number | R | Battery Max A Discharge \[0x006D\] |
|
|
| grid-daily-energy-bought | Number | R | Daily Energy Bought \[0x0208\] |
|
|
| grid-daily-energy-sold | Number | R | Daily Energy Sold \[0x0209\] |
|
|
| grid-external-ct-l1-power | Number | R | External CT L1 Power \[0x0268\] |
|
|
| grid-external-ct-l2-power | Number | R | External CT L2 Power \[0x0269\] |
|
|
| grid-external-ct-l3-power | Number | R | External CT L3 Power \[0x026A\] |
|
|
| grid-grid-voltage-l1 | Number | R | Grid Voltage L1 \[0x0256\] |
|
|
| grid-grid-voltage-l2 | Number | R | Grid Voltage L2 \[0x0257\] |
|
|
| grid-grid-voltage-l3 | Number | R | Grid Voltage L3 \[0x0258\] |
|
|
| grid-internal-ct-l1-power | Number | R | Internal CT L1 Power \[0x025C\] |
|
|
| grid-internal-ct-l2-power | Number | R | Internal CT L2 Power \[0x025D\] |
|
|
| grid-internal-ct-l3-power | Number | R | Internal CT L3 Power \[0x025E\] |
|
|
| grid-total-energy-bought | Number | R | Total Energy Bought \[0x020A,0x020B\] |
|
|
| grid-total-energy-sold | Number | R | Total Energy Sold \[0x020C,0x020D\] |
|
|
| grid-total-grid-power | Number | R | Total Grid Power \[0x0271\] |
|
|
| grid-total-grid-production | Number | R | Total Grid Production \[0x020C,0x020D\] |
|
|
| inverter-ac-temperature | Number | R | AC Temperature \[0x021D\] |
|
|
| inverter-communication-board-version-no- | Number | R | Communication Board Version No \[0x0011\] |
|
|
| inverter-control-board-version-no- | Number | R | Control Board Version No \[0x000D\] |
|
|
| inverter-current-l1 | Number | R | Current L1 \[0x0276\] |
|
|
| inverter-current-l2 | Number | R | Current L2 \[0x0277\] |
|
|
| inverter-current-l3 | Number | R | Current L3 \[0x0278\] |
|
|
| inverter-dc-temperature | Number | R | DC Temperature \[0x021C\] |
|
|
| inverter-frequency | Number | R | Inverter Frequency \[0x27E\] |
|
|
| inverter-inverter-id | String | R | Inverter ID \[0x0003,0x0004,0x0005,0x0006,0x0007\] |
|
|
| inverter-inverter-l1-power | Number | R | Inverter L1 Power \[0x0279\] |
|
|
| inverter-inverter-l2-power | Number | R | Inverter L2 Power \[0x027A\] |
|
|
| inverter-inverter-l3-power | Number | R | Inverter L3 Power \[0x027B\] |
|
|
| solar-daily-production | Number | R | Daily Production \[0x0211\] |
|
|
| solar-pv1-current | Number | R | PV1 Current \[0x02A5\] |
|
|
| solar-pv1-power | Number | R | PV1 Power \[0x02A0\] |
|
|
| solar-pv1-voltage | Number | R | PV1 Voltage \[0x02A4\] |
|
|
| solar-pv2-current | Number | R | PV2 Current \[0x02A7\] |
|
|
| solar-pv2-power | Number | R | PV2 Power \[0x02A1\] |
|
|
| solar-pv2-voltage | Number | R | PV2 Voltage \[0x02A6\] |
|
|
| solar-total-production | Number | R | Total Production \[0x0216,0x0217\] |
|
|
| upload-daily-load-consumption | Number | R | Daily Load Consumption \[0x020E\] |
|
|
| upload-load-l1-power | Number | R | Load L1 Power \[0x028A\] |
|
|
| upload-load-l2-power | Number | R | Load L2 Power \[0x028B\] |
|
|
| upload-load-l3-power | Number | R | Load L3 Power \[0x028C\] |
|
|
| upload-load-voltage-l1 | Number | R | Load Voltage L1 \[0x0284\] |
|
|
| upload-load-voltage-l2 | Number | R | Load Voltage L2 \[0x0285\] |
|
|
| upload-load-voltage-l3 | Number | R | Load Voltage L3 \[0x0286\] |
|
|
| upload-total-load-consumption | Number | R | Total Load Consumption \[0x020F,0x0210\] |
|
|
| upload-total-load-power | Number | R | Total Load Power \[0x028D\] |
|
|
|
|
## Full Example
|
|
|
|
This is an example for a DEYE 12kW (SUN-12K-SG04LP3-EU) hybrid inverter
|
|
|
|
### `solarman.things`
|
|
|
|
Please replace the `hostname` and `serialNumber` with the correct values for your logger.
|
|
|
|
```java
|
|
Thing solarman:logger:local [hostname="x.x.x.x",inverterType="deye_sg04lp3",serialNumber="1234567890"]
|
|
```
|
|
|
|
### `solarman.items`
|
|
|
|
Items file example for a SUN-12K-SG04LP3-EU inverter
|
|
|
|
```text
|
|
Number:Temperature AC_Temperature "AC Temperature [%.1f °C]" (solarman) {channel="solarman:logger:local:inverter-ac-temperature", unit="°C"}
|
|
Number Alert "Alert [%s]" (solarman) {channel="solarman:logger:local:alert-alert"}
|
|
Number:ElectricPotential Battery_Absorption_V "Battery Absorption V [%.2f V]" (solarman) {channel="solarman:logger:local:battery-battery-absorption-v", unit="V"}
|
|
Number:ElectricCharge Battery_Capacity "Battery Capacity [%d Ah]" (solarman) {channel="solarman:logger:local:battery-battery-capacity", unit="Ah"}
|
|
Number:ElectricCurrent Battery_Current "Battery Current [%.1f A]" (solarman) {channel="solarman:logger:local:battery-battery-current", unit="A"}
|
|
Number:Energy Daily_Battery_Charge "Daily Battery Charge [%.1f kWh]" (solarman) {channel="solarman:logger:local:battery-daily-battery-charge", unit="kWh"}
|
|
Number:Energy Daily_Battery_Discharge "Daily Battery Discharge [%.1f kWh]" (solarman) {channel="solarman:logger:local:battery-daily-battery-discharge", unit="kWh"}
|
|
Number:ElectricPotential Battery_Empty_V "Battery Empty V [%.2f V]" (solarman) {channel="solarman:logger:local:battery-battery-empty-v", unit="V"}
|
|
Number:ElectricPotential Battery_Equalization_V "Battery Equalization V [%.2f V]" (solarman) {channel="solarman:logger:local:battery-battery-equalization-v", unit="V"}
|
|
Number:ElectricPotential Battery_Float_V "Battery Float V [%.2f V]" (solarman) {channel="solarman:logger:local:battery-battery-float-v", unit="V"}
|
|
Number:ElectricCurrent Battery_Max_A_Charge "Battery Max A Charge [%d A]" (solarman) {channel="solarman:logger:local:battery-battery-max-a-charge", unit="A"}
|
|
Number:ElectricCurrent Battery_Max_A_Discharge "Battery Max A Discharge [%d A]" (solarman) {channel="solarman:logger:local:battery-battery-max-a-discharge", unit="A"}
|
|
Number:Dimensionless Battery_SOC "Battery SOC [%d %%]" (solarman) {channel="solarman:logger:local:battery-battery-soc", unit="%"}
|
|
Number:Power Battery_Power "Battery Power [%d W]" (solarman) {channel="solarman:logger:local:battery-battery-power", unit="W"}
|
|
Number:Temperature Battery_Temperature "Battery Temperature [%.1f °C]" (solarman) {channel="solarman:logger:local:battery-battery-temperature", unit="°C"}
|
|
Number:ElectricPotential Battery_Voltage "Battery Voltage [%.2f V]" (solarman) {channel="solarman:logger:local:battery-battery-voltage", unit="V"}
|
|
Number:Dimensionless Communication_Board_Version_No "Communication Board Version No [%s]" (solarman) {channel="solarman:logger:local:inverter-communication-board-version-no-"}
|
|
Number:Dimensionless Control_Board_Version_No "Control Board Version No [%s]" (solarman) {channel="solarman:logger:local:inverter-control-board-version-no-"}
|
|
Number:ElectricCurrent Current_L1 "Current L1 [%.1f A]" (solarman) {channel="solarman:logger:local:inverter-current-l1", unit="A"}
|
|
Number:ElectricCurrent Current_L2 "Current L2 [%.1f A]" (solarman) {channel="solarman:logger:local:inverter-current-l2", unit="A"}
|
|
Number:ElectricCurrent Current_L3 "Current L3 [%.1f A]" (solarman) {channel="solarman:logger:local:inverter-current-l3", unit="A"}
|
|
Number:Energy Daily_Energy_Bought "Daily Energy Bought [%d kWh]" (solarman) {channel="solarman:logger:local:grid-daily-energy-bought", unit="kWh"}
|
|
Number:Energy Daily_Energy_Sold "Daily Energy Sold [%d Wh]" (solarman) {channel="solarman:logger:local:grid-daily-energy-sold", unit="Wh"}
|
|
Number:Energy Daily_Load_Consumption "Daily Load Consumption [%.1f kWh]" (solarman) {channel="solarman:logger:local:upload-daily-load-consumption", unit="kWh"}
|
|
Number:Energy Daily_Production "Daily Production [%.1f kWh]" (solarman) {channel="solarman:logger:local:solar-daily-production", unit="kWh"}
|
|
Number:Temperature DC_Temperature "DC Temperature [%.1f °C]" (solarman) {channel="solarman:logger:local:inverter-dc-temperature", unit="°C"}
|
|
Number:Power External_CT_L1_Power "External CT L1 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-external-ct-l1-power", unit="W"}
|
|
Number:Power External_CT_L2_Power "External CT L2 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-external-ct-l2-power", unit="W"}
|
|
Number:Power External_CT_L3_Power "External CT L3 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-external-ct-l3-power", unit="W"}
|
|
Number:Power Gen_Port_A_Phase_Power "Phase Power of Gen Port A [%d W]" (solarman) {channel="solarman:logger:local:smartload-phase-power-of-gen-port-a", unit="W"}
|
|
Number:Power Gen_Port_B_Phase_Power "Phase Power of Gen Port B [%d W]" (solarman) {channel="solarman:logger:local:smartload-phase-power-of-gen-port-b", unit="W"}
|
|
Number:Power Gen_Port_C_Phase_Power "Phase Power of Gen Port C [%d W]" (solarman) {channel="solarman:logger:local:smartload-phase-power-of-gen-port-c", unit="W"}
|
|
Number:ElectricPotential Gen_Port_A_Phase_Voltage "Phase Voltage of Gen Port A [%d V]" (solarman) {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-a", unit="V"}
|
|
Number:ElectricPotential Gen_Port_B_Phase_Voltage "Phase Voltage of Gen Port B [%d V]" (solarman) {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-b", unit="V"}
|
|
Number:ElectricPotential Gen_Port_C_Phase_Voltage "Phase Voltage of Gen Port C [%d V]" (solarman) {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-c", unit="V"}
|
|
String Inverter_Id "Inverter Id [%s]" (solarman) {channel="solarman:logger:local:inverter-inverter-id"}
|
|
Number:Power Inverter_L1_Power "Inverter L1 Power [%d W]" (solarman) {channel="solarman:logger:local:inverter-inverter-l1-power", unit="W"}
|
|
Number:Power Inverter_L2_Power "Inverter L2 Power [%d W]" (solarman) {channel="solarman:logger:local:inverter-inverter-l2-power", unit="W"}
|
|
Number:Power Inverter_L3_Power "Inverter L3 Power [%d W]" (solarman) {channel="solarman:logger:local:inverter-inverter-l3-power", unit="W"}
|
|
Number:Power Internal_CT_L1_Power "Internal CT L1 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-internal-ct-l1-power", unit="W"}
|
|
Number:Power Internal_CT_L2_Power "Internal CT L2 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-internal-ct-l2-power", unit="W"}
|
|
Number:Power Internal_CT_L3_Power "Internal CT L3 Power [%d W]" (solarman) {channel="solarman:logger:local:grid-internal-ct-l3-power", unit="W"}
|
|
Number:ElectricPotential Load_Voltage_L1 "Load Voltage L1 [%d V]" (solarman) {channel="solarman:logger:local:upload-load-voltage-l1", unit="V"}
|
|
Number:ElectricPotential Load_Voltage_L2 "Load Voltage L2 [%d V]" (solarman) {channel="solarman:logger:local:upload-load-voltage-l2", unit="V"}
|
|
Number:ElectricPotential Load_Voltage_L3 "Load Voltage L3 [%d V]" (solarman) {channel="solarman:logger:local:upload-load-voltage-l3", unit="V"}
|
|
Number:Power Load_L1_Power "Load L1 Power [%d W]" (solarman) {channel="solarman:logger:local:upload-load-l1-power", unit="W"}
|
|
Number:Power Load_L2_Power "Load L2 Power [%d W]" (solarman) {channel="solarman:logger:local:upload-load-l2-power", unit="W"}
|
|
Number:Power Load_L3_Power "Load L3 Power [%d W]" (solarman) {channel="solarman:logger:local:upload-load-l3-power", unit="W"}
|
|
Number:ElectricPotential Grid_Voltage_L1 "Grid Voltage L1 [%d V]" (solarman) {channel="solarman:logger:local:grid-grid-voltage-l1", unit="V"}
|
|
Number:ElectricPotential Grid_Voltage_L2 "Grid Voltage L2 [%d V]" (solarman) {channel="solarman:logger:local:grid-grid-voltage-l2", unit="V"}
|
|
Number:ElectricPotential Grid_Voltage_L3 "Grid Voltage L3 [%d V]" (solarman) {channel="solarman:logger:local:grid-grid-voltage-l3", unit="V"}
|
|
Number:Energy Generator_Daily_Power_Generation "Generator Daily Power Generation [%.1f kWh]" (solarman) {channel="solarman:logger:local:smartload-generator-daily-power-generation", unit="kWh"}
|
|
Number:Energy Generator_Total_Power_Generation "Generator Total Power Generation [%.1f kWh]" (solarman) {channel="solarman:logger:local:smartload-generator-total-power-generation", unit="kWh"}
|
|
Number:Dimensionless Smartload_Enable_Status "Smartload Enable Status [%d]" (solarman) {channel="solarman:logger:local:smartload-smartload-enable-status"}
|
|
Number:Energy Total_Battery_Charge "Total Battery Charge [%d kWh]" (solarman) {channel="solarman:logger:local:battery-total-battery-charge", unit="kWh"}
|
|
Number:Energy Total_Battery_Discharge "Total Battery Discharge [%d kWh]" (solarman) {channel="solarman:logger:local:battery-total-battery-discharge", unit="kWh"}
|
|
Number:Energy Total_Energy_Bought "Total Energy Bought [%d kWh]" (solarman) {channel="solarman:logger:local:grid-total-energy-bought", unit="kWh"}
|
|
Number:Energy Total_Energy_Sold "Total Energy Sold [%d kWh]" (solarman) {channel="solarman:logger:local:grid-total-energy-sold", unit="kWh"}
|
|
Number:Power Total_Gen_Port_Power "Total Power of Gen Port [%d W]" (solarman) {channel="solarman:logger:local:smartload-total-power-of-gen-port", unit="W"}
|
|
Number:Power Total_Grid_Power "Total Instant Grid Power [%d W]" (solarman) {channel="solarman:logger:local:grid-total-grid-power", unit="W"}
|
|
Number:Energy Total_Grid_Production "Total Grid Feed-in [%.1f kWh]" (solarman) {channel="solarman:logger:local:grid-total-grid-production", unit="kWh"}
|
|
Number:Energy Total_Load_Consumption "Total Load Consumption [%d kWh]" (solarman) {channel="solarman:logger:local:upload-total-load-consumption", unit="kWh"}
|
|
Number:Power Total_Load_Power "Total Load Power [%d W]" (solarman) {channel="solarman:logger:local:upload-total-load-power", unit="W"}
|
|
Number:Energy Total_Solar_Production "Total Solar Production [%.1f kWh]" (solarman) {channel="solarman:logger:local:solar-total-production", unit="kWh"}
|
|
Number:Power PV1_Power "PV1 Power [%d W]" (solarman) {channel="solarman:logger:local:solar-pv1-power", unit="W"}
|
|
Number:ElectricCurrent PV1_Current "PV1 Current [%.1f A]" (solarman) {channel="solarman:logger:local:solar-pv1-current", unit="A"}
|
|
Number:ElectricPotential PV1_Voltage "PV1 Voltage [%d V]" (solarman) {channel="solarman:logger:local:solar-pv1-voltage", unit="V"}
|
|
Number:Power PV2_Power "PV2 Power [%d W]" (solarman) {channel="solarman:logger:local:solar-pv2-power", unit="W"}
|
|
Number:ElectricCurrent PV2_Current "PV2 Current [%.1f A]" (solarman) {channel="solarman:logger:local:solar-pv2-current", unit="A"}
|
|
Number:ElectricPotential PV2_Voltage "PV2 Voltage [%d V]" (solarman) {channel="solarman:logger:local:solar-pv2-voltage", unit="V"}
|
|
|
|
Number:Frequency Inverter_Frequency "Inverter Frequency [%.2f Hz]" (solarman) {channel="solarman:logger:local:inverter-frequency", unit="Hz"}
|
|
```
|
|
|
|
### `solarman.sitemap`
|
|
|
|
Sitemap example for a SUN-12K-SG04LP3-EU inverter
|
|
|
|
```perl
|
|
sitemap solarman label="Solarman"
|
|
{
|
|
Frame label="Inverter"{
|
|
Text item=Communication_Board_Version_No icon="solar"
|
|
Text item=Control_Board_Version_No icon="solar"
|
|
Text item=Inverter_Id icon="solar"
|
|
Text item=AC_Temperature icon="temperature"
|
|
Text item=DC_Temperature icon="temperature"
|
|
Text item=Inverter_L1_Power icon="poweroutlet"
|
|
Text item=Inverter_L2_Power icon="poweroutlet"
|
|
Text item=Inverter_L3_Power icon="poweroutlet"
|
|
Text item=Current_L1 icon="line"
|
|
Text item=Current_L2 icon="line"
|
|
Text item=Current_L3 icon="line"
|
|
Text item=Inverter_Frequency icon="line"
|
|
}
|
|
|
|
Frame label="Battery"{
|
|
Text item=Battery_SOC icon="battery"
|
|
Text item=Battery_Current icon="current"
|
|
Text item=Battery_Power icon="power"
|
|
Text item=Battery_Voltage icon="voltage"
|
|
Text item=Battery_Temperature icon="temperature"
|
|
Text item=Daily_Battery_Charge icon="renewable"
|
|
Text item=Daily_Battery_Discharge icon="battery"
|
|
Text item=Total_Battery_Charge icon="renewable"
|
|
Text item=Total_Battery_Discharge icon="battery"
|
|
Text item=Battery_Absorption_V icon="voltage"
|
|
Text item=Battery_Equalization_V icon="voltage"
|
|
Text item=Battery_Float_V icon="voltage"
|
|
Text item=Battery_Empty_V icon="voltage"
|
|
Text item=Battery_Capacity icon="battery"
|
|
Text item=Battery_Max_A_Charge icon="battery"
|
|
Text item=Battery_Max_A_Discharge icon="battery"
|
|
}
|
|
|
|
Frame label="Solar"{
|
|
Text item=Total_Solar_Production icon="solar"
|
|
Text item=Daily_Production icon="solar"
|
|
Text item=PV1_Current icon="solar"
|
|
Text item=PV1_Power icon="solar"
|
|
Text item=PV1_Voltage icon="solar"
|
|
Text item=PV2_Current icon="solar"
|
|
Text item=PV2_Power icon="solar"
|
|
Text item=PV2_Voltage icon="solar"
|
|
}
|
|
|
|
Frame label="Grid"{
|
|
Text item=Total_Grid_Production icon="power"
|
|
Text item=Total_Grid_Power icon="power"
|
|
Text item=External_CT_L1_Power icon="power"
|
|
Text item=External_CT_L2_Power icon="power"
|
|
Text item=External_CT_L3_Power icon="power"
|
|
Text item=Internal_CT_L1_Power icon="power"
|
|
Text item=Internal_CT_L2_Power icon="power"
|
|
Text item=Internal_CT_L3_Power icon="power"
|
|
Text item=Grid_Voltage_L1 icon="power"
|
|
Text item=Grid_Voltage_L2 icon="power"
|
|
Text item=Grid_Voltage_L3 icon="power"
|
|
Text item=Daily_Energy_Sold icon="power"
|
|
Text item=Total_Energy_Sold icon="power"
|
|
Text item=Daily_Energy_Bought icon="power"
|
|
Text item=Total_Energy_Bought icon="power"
|
|
}
|
|
|
|
Frame label="Load"{
|
|
Text item=Daily_Load_Consumption icon="power"
|
|
Text item=Total_Load_Consumption icon="power"
|
|
Text item=Load_L1_Power icon="power"
|
|
Text item=Load_L2_Power icon="power"
|
|
Text item=Load_L3_Power icon="power"
|
|
Text item=Load_Voltage_L1 icon="power"
|
|
Text item=Load_Voltage_L2 icon="power"
|
|
Text item=Load_Voltage_L3 icon="power"
|
|
Text item=Total_Load_Power icon="power"
|
|
}
|
|
|
|
Frame label="Generator"{
|
|
Text item=Gen_Port_A_Phase_Power icon="poweroutlet"
|
|
Text item=Gen_Port_B_Phase_Power icon="poweroutlet"
|
|
Text item=Gen_Port_C_Phase_Power icon="poweroutlet"
|
|
Text item=Gen_Port_A_Phase_Voltage icon="voltage"
|
|
Text item=Gen_Port_B_Phase_Voltage icon="voltage"
|
|
Text item=Gen_Port_C_Phase_Voltage icon="voltage"
|
|
Text item=Total_Gen_Port_Power icon="power"
|
|
Text item=Generator_Daily_Power_Generation icon="power"
|
|
Text item=Generator_Total_Power_Generation icon="power"
|
|
}
|
|
|
|
Frame label="Alert"{
|
|
Text item=Alert icon="alert"
|
|
}
|
|
}
|
|
```
|
|
|
|
## Acknowledgments
|
|
|
|
The code's creation draws significant inspiration from [Stephan Joubert's Home Assistant plugin](https://github.com/StephanJoubert/home_assistant_solarman), which provides the inverter definitions used in the project.
|
|
Additionally, the [pysolarmanv5 module](https://pysolarmanv5.readthedocs.io/en/latest/index.html) was a valuable resource, as it offers an excellent explanation of the Solarman V5 protocol.
|