mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-10 23:22:02 +01:00
87c16da527
Signed-off-by: Hans Böhm <h.boehm@gmx.at>
298 lines
38 KiB
Markdown
298 lines
38 KiB
Markdown
# ComfoAir Binding
|
|
|
|
This binding allows to monitor and control Zehnder ComfoAir serial controlled ventilation systems via RS232 serial connection.
|
|
Though the binding is developed based on the protocol description for Zehnder ComfoAir devices it should also work for mostly identical systems from different manufacturers, like StorkAir WHR930, Wernig G90-380 and Paul Santos 370 DC.
|
|
It was also successfully tested on a Wernig G90-160.
|
|
|
|
### Limitations
|
|
|
|
* Either the ComfoAir binding or the CCEase Comfocontrol can be active, but not together.
|
|
* You must implement auto mode by yourself with rules, but it is more powerful.
|
|
|
|
### Prerequisites
|
|
|
|
Computer communication between ComfoAir device and openHAB via RS232 connection has to be set up.
|
|
The connection should be made with a 3-wire cable connecting pins: GND, TX, RX of RS232 sockets, but RX and TX pins should be crossed (TX of ComfoAir to RX of PC, RX of ComfoAir to TX of PC).
|
|
|
|
### Serial Port Access Rights
|
|
|
|
* Take care that the user that runs openHAB has rights to access the serial port
|
|
* On Ubuntu/Debian based systems (incl. openHABian) that usually means adding the user (e.g. openhab) to the group "dialout", i.e.
|
|
|
|
```
|
|
sudo usermod -a -G dialout openhab
|
|
```
|
|
|
|
## Supported Things
|
|
|
|
Only a single generic thing type is supported by the binding:
|
|
|
|
|Thing Type ID |Description |
|
|
|--------------|---------------------------------------------------------------------|
|
|
|comfoair |A ComfoAir ventilation system connected via RS232 serial connection. |
|
|
|
|
## Discovery
|
|
|
|
Discovery is not supported.
|
|
|
|
## Thing Configuration
|
|
|
|
For the thing creation, the appropriate serial port has to be set.
|
|
|
|
|Parameter |Values |Default |
|
|
|---------------|-----------------------------------------|---------------|
|
|
|serialPort |`/dev/ttyUSB0`, `COM1`, etc. |- |
|
|
|refreshInterval|Refresh interval in seconds (10...65535) |60 |
|
|
|
|
## Channels
|
|
|
|
The ComfoAir binding supports the following channels.
|
|
|
|
| Channel ID | Item Type | Label | Description | Read Only | Advanced |
|
|
|------------------------------------|--------------------------|---------------------------------|---------------------------------------------------------------------------------------------|-----------|----------|
|
|
| **Binding Control** | | | | | |
|
|
| bindingControl#activate | Switch | Activate Binding Control | Activate (control through openHAB) or deactivate (return control to CCEase) binding control | false | no |
|
|
| **Ventilation Values** | | | | | |
|
|
| ventilation#fanLevel | Number | Fan Level | Fan level | false | no |
|
|
| ventilation#fanOut0 | Number | Fan Out Level 0 (away) | Fan level 0 performance (%) of outgoing fan | false | yes |
|
|
| ventilation#fanOut1 | Number | Fan Out Level 1 | Fan level 1 performance (%) of outgoing fan | false | yes |
|
|
| ventilation#fanOut2 | Number | Fan Out Level 2 | Fan level 2 performance (%) of outgoing fan | false | yes |
|
|
| ventilation#fanOut3 | Number | Fan Out Level 3 | Fan level 3 performance (%) of outgoing fan | false | yes |
|
|
| ventilation#fanIn0 | Number | Fan In Level 0 (away) | Fan level 0 performance (%) of incoming fan | false | yes |
|
|
| ventilation#fanIn1 | Number | Fan In Level 1 | Fan level 1 performance (%) of incoming fan | false | yes |
|
|
| ventilation#fanIn2 | Number | Fan In Level 2 | Fan level 2 performance (%) of incoming fan | false | yes |
|
|
| ventilation#fanIn3 | Number | Fan In Level 3 | Fan level 3 performance (%) of incoming fan | false | yes |
|
|
| ventilation#fanInPercent | Number | Fan In (%) | Current relative speed (%) of incoming fan | false | yes |
|
|
| ventilation#fanOutPercent | Number | Fan Out (%) | Current relative speed (%) of outgoing fan | true | yes |
|
|
| ventilation#fanInRPM | Number | Fan In (rpm) | Current absolute speed (rpm) of incoming fan | true | yes |
|
|
| ventilation#fanOutRPM | Number | Fan Out (rpm) | Current absolute speed (rpm) of outgoing fan | true | yes |
|
|
| **Temperature Values** | | | | | |
|
|
| temperatures#targetTemperature | Number:Temperature | Target Temperature | Target (comfort) temperature | false | no |
|
|
| temperatures#outdoorTemperatureIn | Number:Temperature | Outdoor Temperature Incoming | Intake air temperature (outside) | true | yes |
|
|
| temperatures#outdoorTemperatureOut | Number:Temperature | Outdoor Temperature Outgoing | Outlet air temperature (outside) | true | yes |
|
|
| temperatures#indoorTemperatureIn | Number:Temperature | Indoor Temperature Incoming | Inlet air temperature (inside) | true | yes |
|
|
| temperatures#indoorTemperatureOut | Number:Temperature | Indoor Temperature Outgoing | Uptake air temperature (inside) | true | yes |
|
|
| temperatures#isT1Sensor | Switch | Sensor T1 Available | Availability of temperature sensor T1 (outdoor in) | true | yes |
|
|
| temperatures#isT2Sensor | Switch | Sensor T2 Available | Availability of temperature sensor T2 (indoor in) | true | yes |
|
|
| temperatures#isT3Sensor | Switch | Sensor T3 Available | Availability of temperature sensor T3 (indoor out) | true | yes |
|
|
| temperatures#isT4Sensor | Switch | Sensor T4 Available | Availability of temperature sensor T4 (outdoor out) | true | yes |
|
|
| temperatures#isEWTSensor | Switch | GHX Sensor Available | Availability of geothermal heat exchanger temperature sensor | true | yes |
|
|
| temperatures#isHeaterSensor | Switch | Heater Sensor Available | Availability of heater temperature sensor | true | yes |
|
|
| temperatures#isCookerhoodSensor | Switch | Cookerhood Sensor Available | Availability of cookerhood temperature sensor | true | yes |
|
|
| temperatures#ewtTemperature | Number:Temperature | GHX Temperature | Temperature of geothermal heat exchanger sensor | true | yes |
|
|
| temperatures#heaterTemperature | Number:Temperature | Heater Temperature | Temperature of heater sensor | true | yes |
|
|
| temperatures#cookerhoodTemperature | Number:Temperature | Cookerhood Temperature | Temperature of cookerhood sensor | true | yes |
|
|
| **Uptimes** | | | | | |
|
|
| times#level0Time | Number:Time | Level 0 duration | Uptime at level 0 (away) | true | yes |
|
|
| times#level1Time | Number:Time | Level 1 duration | Uptime at level 1 | true | yes |
|
|
| times#level2Time | Number:Time | Level 2 duration | Uptime at level 2 | true | yes |
|
|
| times#level3Time | Number:Time | Level 3 duration | Uptime at level 3 | true | yes |
|
|
| times#freezeTime | Number:Time | Antifrost Duration | Uptime of antifrost | true | yes |
|
|
| times#preheaterTime | Number:Time | Preheater Duration | Uptime of preheater | true | yes |
|
|
| times#bypassTime | Number:Time | Bypass Duration | Hours of bypass open | true | yes |
|
|
| times#filterHours | Number:Time | Filter Duration | Uptime of the filter | true | no |
|
|
| **Menu P1: Control States** | | | | | |
|
|
| menuP1#menu20Mode | Switch | Menu 20 Mode (P10) | State of menu 20 mode (P10) | true | yes |
|
|
| menuP1#menu21Mode | Switch | Menu 21 Mode (P11) | State of menu 21 mode (P11) | true | yes |
|
|
| menuP1#menu22Mode | Switch | Menu 22 Mode (P12) | State of menu 22 mode (P12) | true | yes |
|
|
| menuP1#menu23Mode | Switch | Menu 23 Mode (P13) | State of menu 23 mode (P13) | true | yes |
|
|
| menuP1#menu24Mode | Switch | Menu 24 Mode (P14) | State of menu 24 mode (P14) | true | yes |
|
|
| menuP1#menu25Mode | Switch | Menu 25 Mode (P15) | State of menu 25 mode (P15) | true | yes |
|
|
| menuP1#menu26Mode | Switch | Menu 26 Mode (P16) | State of menu 26 mode (P16) | true | yes |
|
|
| menuP1#menu27Mode | Switch | Menu 27 Mode (P17) | State of menu 27 mode (P17) | true | yes |
|
|
| menuP1#menu28Mode | Switch | Menu 28 Mode (P18) | State of menu 28 mode (P18) | true | yes |
|
|
| menuP1#menu29Mode | Switch | Menu 29 Mode (P19) | State of menu 29 mode (P19) | true | yes |
|
|
| **Menu P2: Delay Settings** | | | | | |
|
|
| menuP2#bathroomStartDelay | Number | Menu P21 | Start delay for bathroom switch (min) | false | yes |
|
|
| menuP2#bathroomEndDelay | Number | Menu P22 | End delay for bathroom switch (min) | false | yes |
|
|
| menuP2#L1EndDelay | Number | Menu P23 | End delay for L1 switch (min) | false | yes |
|
|
| menuP2#pulseVentilation | Number | Menu P27 | Period for pulse ventilation (min) | false | yes |
|
|
| menuP2#filterWeeks | Number | Menu P24 | Usage period until filter pollution message (weeks) | false | yes |
|
|
| menuP2#RFShortDelay | Number | Menu P25 | End delay (RF short actuation) for ventilation level 3 (min) | false | yes |
|
|
| menuP2#RFLongDelay | Number | Menu P26 | End delay (RF long actuation) for ventilation level 3 (min) | false | yes |
|
|
| menuP2#cookerhoodDelay | Number | Menu P20 | End delay for cooker hood control (min) | false | yes |
|
|
| **Menu P9: Option States** | | | | | |
|
|
| menuP9#chimneyState | Switch | Chimney Control State | State of the chimney control | true | yes |
|
|
| menuP9#bypassState | Switch | Bypass State | State of the bypass (ON = open / OFF = closed) | true | yes |
|
|
| menuP9#ewtState | Switch | GHX State | State of the geothermal heat exchanger valve (ON = open / OFF = closed) | true | yes |
|
|
| menuP9#heaterState | Switch | Heater State | State of the heater | true | yes |
|
|
| menuP9#vControlState | Switch | 0-10V Control State | State of the 0-10V control | true | yes |
|
|
| menuP9#frostState | Switch | Antifrost State | State of the antifrost control | true | yes |
|
|
| menuP9#cookerhoodState | Switch | Cookerhood State | State of the cookerhood control | true | yes |
|
|
| menuP9#enthalpyState | Switch | Enthalpy State | State of the enthalpy module | true | yes |
|
|
| **Error States** | | | | | |
|
|
| errors#filterError | Switch | Filter Error | Filter full | true | no |
|
|
| errors#errorsCurrent | String | Errors Current | Current errors | true | no |
|
|
| errors#errorsLast | String | Errors Last | Last errors | true | yes |
|
|
| errors#errorsPrelast | String | Errors Prelast | Prelast errors | true | yes |
|
|
| errors#errorsPrePrelast | String | Errors Pre-Prelast | Pre-Prelast errors | true | yes |
|
|
| **Bypass Values** | | | | | |
|
|
| bypass#bypassFactor | Number | Bypass Factor | Bypass factor value | true | yes |
|
|
| bypass#bypassLevel | Number | Bypass Level | Bypass level state | true | yes |
|
|
| bypass#bypassCorrection | Number | Bypass Correction | Bypass correction state | true | yes |
|
|
| bypass#bypassSummer | Switch | Bypass Summer Mode | Bypass summer mode | true | yes |
|
|
| **Preheater Values** | | | | | |
|
|
| preheater#preheaterValve | Number | Preheater Valve | State of the preheater valve | true | yes |
|
|
| preheater#preheaterFrostProtect | Switch | Frost Protection | State of the frost protection | true | yes |
|
|
| preheater#preheaterHeating | Switch | Preheater | State of the preheater | true | yes |
|
|
| preheater#preheaterFrostTime | Number | Preheater Frost Time | Frost minutes | true | yes |
|
|
| preheater#preheaterSafety | Number | Preheater Frost Safety | Frost safety setting | true | yes |
|
|
| **GHX Values** | | | | | |
|
|
| ewt#ewtTemperatureLow | Number:Temperature | GHX Temperature (low) | Lower temperature of the geothermal heat exchanger | true | yes |
|
|
| ewt#ewtTemperatureHigh | Number:Temperature | GHX Temperature (high) | Upper temperature of the geothermal heat exchanger | true | yes |
|
|
| ewt#ewtSpeed | Number | GHX Speed Up (%) | Speed up of the geothermal heat exchanger | true | yes |
|
|
| **Heater Values** | | | | | |
|
|
| heater#heaterPower | Number | Heater Power | Heater power value | true | yes |
|
|
| heater#heaterPowerI | Number | Heater Power I-parameter | Heater power I-parameter value | true | yes |
|
|
| heater#heaterTargetTemperature | Number:Temperature | Heater Target Temperature | Target temperature of the heater | true | yes |
|
|
| **Cookerhood Values** | | | | | |
|
|
| cookerhood#cookerhoodSpeed | Number | Cookerhood Speed Up (%) | Speed up of the cookerhood | true | yes |
|
|
| **Enthalpy Values** | | | | | |
|
|
| enthalpy#enthalpyTemperature | Number:Temperature | Enthalpy Sensor Temperature | Temperature of the enthalpy sensor | true | yes |
|
|
| enthalpy#enthalpyHumidity | Number | Enthalpy Sensor Humidity | Humidity of the enthalpy sensor | true | yes |
|
|
| enthalpy#enthalpyLevel | Number | Enthalpy Sensor Level | Level of the enthalpy sensor | true | yes |
|
|
| enthalpy#enthalpyTime | Number | Enthalpy Sensor Timer | Timer state of the enthalpy sensor | true | yes |
|
|
| **Option Settings** | | | | | |
|
|
| options#isPreheater | Switch | Preheater | Preheater option installed | true | yes |
|
|
| options#isBypass | Switch | Bypass | Bypass option installed | true | yes |
|
|
| options#recuType | Number | ComfoAir Type | Type of the ComfoAir (1 = left / 2 = right) | true | yes |
|
|
| options#recuSize | Number | ComfoAir Size | Size of the ComfoAir (1 = big / 2 = small) | true | yes |
|
|
| options#isChimney | Switch | Chimney | Chimney option installed | true | yes |
|
|
| options#isCookerhood | Switch | Cookerhood | Cookerhood option installed | true | yes |
|
|
| options#isHeater | Switch | Heater | Heater option installed | true | yes |
|
|
| options#isEnthalpy | Number | Enthalpy | Enthalpy option installed | true | yes |
|
|
| options#isEWT | Number | Geothermal Heat Exchanger | Geothermal heat exchanger option installed | true | yes |
|
|
| options#analogPriority | Number | Analog Priority | Priority of analog inputs for highest fan level | true | yes |
|
|
| **Inputs** | | | | | |
|
|
| inputs#isL1Switch | Switch | L1 Switch | Availability of L1 step switch | true | yes |
|
|
| inputs#isL2Switch | Switch | L2 Switch | Availability of L2 step switch | true | yes |
|
|
| inputs#isBathroomSwitch | Switch | Bathroom Switch | Availability of bathroom switch | true | yes |
|
|
| inputs#isCookerhoodSwitch | Switch | Cookerhood Switch | Availability of cookerhood switch | true | yes |
|
|
| inputs#isExternalFilter | Switch | External Filter | Availability of external filter | true | yes |
|
|
| inputs#isWTW | Switch | Heat Recovery | Availability of heat recovery (WTW) | true | yes |
|
|
| inputs#isBathroom2Switch | Switch | Bathroom Switch 2 | Availability of bathroom switch 2 (luxe) | true | yes |
|
|
| **Resets** | | | | | |
|
|
| resets#filterReset | Number | Filter Reset | Reset filter uptime | false | no |
|
|
| resets#errorReset | Number | Error Reset | Reset errors | false | no |
|
|
| **Analog Inputs [1-4]** | | | | | |
|
|
| analog[1-4]#isAnalog | Switch | Analog Input Availability | Availability of analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogMode | Switch | Analog Input State | State of analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogNegative | Switch | Analog Input Postive/Negative | Postive/Negative state of analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogVolt | Number:ElectricPotential | Analog Input Voltage Level | Voltage level of analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogMin | Number | Analog Input Min | Minimum setting for analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogMax | Number | Analog Input Max | Maximum setting for analog input [1-4] | false | yes |
|
|
| analog[1-4]#analogValue | Number | Analog Input Target | Target setting for analog input [1-4] | false | yes |
|
|
| **RF Input** | | | | | |
|
|
| analogRF#isRF | Switch | RF Input Availability | Availability of RF input | false | yes |
|
|
| analogRF#RFMode | Switch | RF Input State | State of RF input | false | yes |
|
|
| analogRF#RFNegative | Switch | RF Input Postive/Negative | Postive/Negative state of RF input | false | yes |
|
|
| analogRF#RFMin | Number | RF Input Min | Minimum setting for RF input | false | yes |
|
|
| analogRF#RFMax | Number | RF Input Max | Maximum setting for RF input | false | yes |
|
|
| analogRF#RFValue | Number | RF Input Target | Target setting for RF input | false | yes |
|
|
| analogRF#analogPriority | Number | Analog Priority | Priority of control | false | yes |
|
|
|
|
## Full Example
|
|
|
|
`.things` file:
|
|
|
|
```
|
|
Thing comfoair:comfoair:myComfoAir "ComfoAir" [serialPort="/dev/ttyUSB0", refreshInterval="60"]
|
|
```
|
|
|
|
`.items` file:
|
|
|
|
```
|
|
Switch comfoairControl "Activate" <computer> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:bindingControl#activate"}
|
|
Number comfoairFanLevel "Ventilation level [%d]" <chart> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:ventilation#fanLevel"}
|
|
Number comfoairErrorReset "Error reset" <service> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:resets#errorReset"}
|
|
Number comfoairFilterReset "Filter reset" <service> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:resets#filterReset"}
|
|
Number comfoairFilterPeriod "Filter period [%d weeks]" <clock> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP2#filterWeeks"}
|
|
|
|
// Messages
|
|
String comfoairError "Error: [%s]" (ComfoAir) {channel="comfoair:comfoair:myComfoAir:errors#errorsCurrent"}
|
|
Number:Time comfoairFilterRuntime "Filter runtime [%.0f h]" (ComfoAir) {channel="comfoair:comfoair:myComfoAir:times#filterHours"}
|
|
|
|
// State
|
|
Number:Temperature comfoairTargetTemperature "Comfort temperature [%.1f °C]" <temperature> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:temperatures#targetTemperature"}
|
|
Number:Temperature comfoairOutdoorIncomingTemperature "Inlet air temperature [%.1f °C]" <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#outdoorTemperatureIn"}
|
|
Number:Temperature comfoairIndoorIncomingTemperature "Supply air temperature [%.1f °C]" <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#indoorTemperatureIn"}
|
|
Number:Temperature comfoairIndoorOutgoingTemperature "Return air temperature [%.1f °C]" <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#indoorTemperatureOut"}
|
|
Number:Temperature comfoairOutdoorOutgoingTemperature "Exhaust air temperature [%.1f °C]" <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#outdoorTemperatureOut"}
|
|
Number comfoairIncomingFan "Supply capacity [%d %%]" <fan_in> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:ventilation#fanInPercent"}
|
|
Number comfoairOutgoingFan "Exhaust capacity [%d %%]" <fan_out> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:ventilation#fanOutPercent"}
|
|
Number comfoairFanIn0 "Supply capacity - level 0 [%d %%]" <fan_in> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:ventilation#fanIn0"}
|
|
Number comfoairFanOut0 "Exhaust capacity - level 0 [%d %%]" <fan_out> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:ventilation#fanOut0"}
|
|
Switch comfoairBypassMode "Bypass [MAP(comfoair_bypass.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#bypassState"}
|
|
Switch comfoairGHXMode "GHX [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#ewtState"}
|
|
Switch comfoairChimneyMode "Fire programme [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#chimneyState"}
|
|
Switch comfoairHeaterMode "Heater [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#heaterState"}
|
|
Switch comfoairCookerHoodMode "Extractor hood [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#cookerhoodState"}
|
|
Switch comfoairEnthalpyMode "Enthalpy [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#enthalpyState"}
|
|
Switch comfoairFreezeMode "Freeze [MAP(comfoair_freeze.map):%s]" <climate> (ComfoAir) {channel="comfoair:comfoair:myComfoAir:menuP9#frostState"}
|
|
```
|
|
|
|
`.sitemap` file:
|
|
|
|
```
|
|
sitemap comfoair label="ComfoAir" {
|
|
Frame label="Main" {
|
|
Text item=comfoairError labelcolor=[!="No Errors"="red"] valuecolor=[!="No Errors"="red"]
|
|
Switch item=comfoairControl mappings=[0="CCEase", 1="Computer"]
|
|
Switch item=comfoairErrorReset mappings=[1="Reset"]
|
|
Switch item=comfoairFilterReset mappings=[1="Reset"]
|
|
}
|
|
Frame label="Control" {
|
|
Selection item=comfoairFanLevel
|
|
Setpoint item=comfoairTargetTemperature step=0.5 minValue=15 maxValue=28 valuecolor=["black"]
|
|
}
|
|
Frame label="State" {
|
|
Text item=comfoairOutdoorIncomingTemperature valuecolor=["black"]
|
|
Text item=comfoairOutdoorOutgoingTemperature valuecolor=["black"]
|
|
Text item=comfoairIndoorIncomingTemperature valuecolor=["black"]
|
|
Text item=comfoairIndoorOutgoingTemperature valuecolor=["black"]
|
|
}
|
|
Frame {
|
|
Text item=comfoairIncomingFan valuecolor=["black"]
|
|
Text item=comfoairBypassMode valuecolor=["black"]
|
|
Text item=comfoairOutgoingFan valuecolor=["black"]
|
|
Text item=comfoairGHXMode valuecolor=[OFF="silver", ON="black"]
|
|
Text item=comfoairEfficiency valuecolor=["black"]
|
|
Text item=comfoairFreezeMode valuecolor=[OFF="black", ON="red"]
|
|
Text item=comfoairFilterRuntime_Message valuecolor=["black"]
|
|
Text item=comfoairChimneyMode valuecolor=[OFF="silver", ON="black"]
|
|
}
|
|
}
|
|
```
|
|
|
|
`comfoair_bypass.map` file:
|
|
|
|
```
|
|
ON=Opened
|
|
OFF=Closed
|
|
undefined=unknown
|
|
-=unknown
|
|
```
|
|
|
|
`comfoair_on-off.map` file:
|
|
|
|
```
|
|
ON=active
|
|
OFF=inactive
|
|
undefined=unknown
|
|
-=unknown
|
|
```
|
|
|
|
`comfoair_freeze.map` file:
|
|
|
|
```
|
|
ON=frozen
|
|
OFF=OK
|
|
undefined=unknown
|
|
-=unknown
|
|
```
|
|
|
|
## Control Protocol Reference
|
|
|
|
For reference the protocol description used can be found here (german version only):
|
|
[Protokollbeschreibung Zehnder ComfoAir](http://www.see-solutions.de/sonstiges/Protokollbeschreibung_ComfoAir.pdf)
|