* Apply markdown fixes for bindings with letter _t_ * Apply markdown fixes for bindings with letter _u_ * Apply markdown fixes for bindings with letter _v_ * Apply markdown fixes for bindings with letter _w_ * Apply markdown fixes for bindings with letter _x_ * Apply markdown fixes for bindings with letter _y_ * Apply markdown fixes for bindings with letter _z_ Signed-off-by: Jerome Luckenbach <github@luckenba.ch>
131 lines
8.5 KiB
Markdown
131 lines
8.5 KiB
Markdown
# Vitotronic Binding
|
|
|
|
Viessmann heating systems with Vitotronic has an optolink Interface for maintenance.
|
|
This interface can use for get/set data in the heating system. [see on openv](https://github.com/openv/openv/wiki/)
|
|
|
|
The Vitotronic binding is a solution to bind this interface into openHAB.
|
|
It supports the separation of the heating adaption from the integration in [openHAB](https://www.openhab.org/).
|
|
|
|
![Architecture](doc/architecture_vitotronic.jpg)
|
|
|
|
The adapter transforms the address oriented raw interface of the Vitotronic to an abstract format.
|
|
The adapter itself is not a part of the binding.
|
|
[An alpha version is available here](https://github.com/steand/optolink)
|
|
[More Information about the adapter](https://github.com/steand/optolink/wiki)
|
|
|
|
## Supported Things
|
|
|
|
For easy using are the main things of a heating system are already define in this binding:
|
|
|
|
- heating (Vitotronic core system)
|
|
- pelletburner (Pellet Fireplace, works for wood also)
|
|
- oilburner (Oil Fireplace)
|
|
- gasburner (Gas Fireplace)
|
|
- storagetank (Storage Tank, stores heat in a water tank on 3 levels: bottom, middle, top=hot water)
|
|
- circuit (Heating circuit controls the flow between the heating system and the radiators in the rooms)
|
|
- solar (Solar water heating (SWH): Convert sunlight into energy for water heating)
|
|
|
|
For advanced used 3 basic things of a headingsystem define also.
|
|
|
|
- temperaturesensor (Single temperature sensor)
|
|
- pump (Single pump)
|
|
- valve (Single valve)
|
|
|
|
Note: The mapping of things and channels to the heating system addresses must be done in the adapter.
|
|
|
|
## Discovery
|
|
|
|
The binding discovers the adapter with broadcast and puts any `vitotronic:bridge` found into the inbox.
|
|
For automatic detection the adapter and **openHAB** must be on the same LAN.
|
|
If the bridge isn't on the same LAN, you will need to add manually.
|
|
In this case the `IP-Address` and the `adapterID` is required.
|
|
After the `vitotronic:bridge` is ONLINE, start a second discovery.
|
|
It discovers all things, and places them in the inbox.
|
|
|
|
## Binding Configuration
|
|
|
|
Binding itself has 4 configuration parameters:
|
|
|
|
- ipAddress (The IP address of the Optolink adapter)
|
|
- port (Port of the LAN gateway. Default: 31113)
|
|
- adapterID (The ID/Name of the adapter)
|
|
- refreshInterval (Refresh time for data in seconds. Default: 600 seconds)
|
|
|
|
If the adapter is automatic discovered the ipAddress, and adapterID will be set by discovery.
|
|
The rereshInterval can be set between 60 and 600 seconds.
|
|
The minimal setting is dependent of the performance of the adapter.
|
|
|
|
## Thing Configuration
|
|
|
|
There is no configuration of Things necessary.
|
|
Only some channels are set active by default.
|
|
If this channels are defined in the adapter and will be used in **openHAB** it must set active manually.
|
|
Don't change the Thing Name. It is the reference to the name in the adapter.
|
|
|
|
## Channels
|
|
|
|
The follow channels are implemented:
|
|
|
|
| Channel Type ID | Item Type | Description |
|
|
|------------------------|-----------|-------------------------------------------------------|
|
|
| systemtime | DateTime | DateTime of the heating system |
|
|
| outside_temp | Number | Outside temperature sensor |
|
|
| boiler_temp | Number | Temperature sensor of boiler (fireplace) |
|
|
| malfunction | Switch | General malfunction state of the heating system |
|
|
| exhaust_temp | Number | Exhaust temperature |
|
|
| flowuprating | Switch | Pump state of flow up rating |
|
|
| flame_temp | Number | Temperature of flame |
|
|
| airshutter_prim | Number | Position of the primary air shutter |
|
|
| airshutter_sec | Number | Position of the secondary air shutter |
|
|
| lambdasensor | Number | Oxygen content of the exhaust air |
|
|
| fanspeed | Number | Fan Speed in rpm |
|
|
| fanspeed_target | Number | Fan Speed in rpm |
|
|
| error | Switch | |
|
|
| starts | Number | Count of starts |
|
|
| ontime | Number | Ontime in hours |
|
|
| consumedpellets | Number | Consumed Pellets since start of heating in tons |
|
|
| power | Number | Power of the pellet burner |
|
|
| powerlevel | Number | Power of the oil/gas burner |
|
|
| actualpower | Number | Actual power of the burner |
|
|
| ontimelevel1 | Number | Ontime in hours |
|
|
| ontimelevel2 | Number | Ontime in hours |
|
|
| consumedoil | Number | Consumed Oil since start of heating in Liter |
|
|
| hotwater_temp | Number | Temperature sensor of the hot water |
|
|
| hotwater_temp_setpoint | Number | Hot water temperature setpoint (target) |
|
|
| middle_temp | Number | Temperature sensor in the middle of the storage tank |
|
|
| bottom_temp | Number | Temperature sensor at the bottom of the storage tank |
|
|
| circuitpump | Switch | Circuit pump state |
|
|
| flowtemperature | Number | Temperature sensor of the ciruit flow |
|
|
| pump | Switch | Pump state |
|
|
| operationmode | Number | Operationmode |
|
|
| currentmode | Number | Current Mode
|
|
| savemode | Switch | Savemode on/off |
|
|
| partymode | Switch | Partymode on/off |
|
|
| party_temp_setpoint | Number | Party mode temperature setpoint (target) |
|
|
| room_temp | Number | Target temperature of rooms |
|
|
| room_temp_setpoint | Number | Room temperature setpoint (target) |
|
|
| save_temp_setpoint | Number | Save mode temperature setpoint (target) |
|
|
| gradient | Number | The gradient relativ to outside temperature |
|
|
| niveau | Number | The niveau relativ to outside temperature |
|
|
| timer_MO | String | Heating timer for Monday |
|
|
| timer_TU | String | Heating timer for Tuesday |
|
|
| timer_WE | String | Heating timer for Wednesday |
|
|
| timer_TH | String | Heating timer for Thursday |
|
|
| timer_FR | String | Heating timer for Friday |
|
|
| timer_SA | String | Heating timer for Saturday |
|
|
| timer_SU | String | Heating timer for Sunday |
|
|
| timer_ww_MO | String | Hot water timer for Monday |
|
|
| timer_ww_TU | String | Hot water timer for Tuesday |
|
|
| timer_ww_WE | String | Hot water timer for Wednesday |
|
|
| timer_ww_TH | String | Hot water timer for Thursday |
|
|
| timer_ww_FR | String | Hot water timer for Friday |
|
|
| timer_ww_SA | String | Hot water timer for Saturday |
|
|
| timer_ww_SU | String | Hot water timer for Sunday |
|
|
| collector_temp | Number | Actual temperature of the collector |
|
|
| storagetank_temp | Number | Actual temperature of the storage tank (solar sensor) |
|
|
| bufferload | Switch | State of the pump (on/off) |
|
|
| loadsuppression | Switch | State of the load suppression (on/off) |
|
|
| producedheat | Number | Produced heat since starting solar system |
|
|
| temperature | Number | Generic temperature sensor |
|
|
| valve | Number | Value of a generic valve |
|