# Teleinfo Binding
|
|
|
|
The Teleinfo binding supports an interface to ENEDIS/ERDF [Teleinfo protocol](https://www.enedis.fr/sites/default/files/Enedis-NOI-CPT_54E.pdf) for (French) Electricity Meter. This binding works with a Teleinfo modem plugged to the I1 and I2 terminals of your electricity meter. Teleinfo modems can be ordered (see the [list of tested hardware](#tested-hardware) below) or build by yourself (see [this example](http://bernard.lefrancois.free.fr)).
|
|
|
|
Teleinfo is a protocol to read many electrical statistics of your electricity meter: instantaneous power consumption, current price period, meter reading...
|
|
These values can be used to
|
|
|
|
- send your meter reading to your electricity provider with a simple copy/paste,
|
|
- improve your rules and minimize electricity costs,
|
|
- check if your subscription is relevant for your needs,
|
|
- monitor your electricity consumption,
|
|
|
|
## Supported Things
|
|
|
|
### Historical TIC mode
|
|
|
|
Historical TIC mode is the only mode of all telemeters before Linky models and the default mode for Linky telemeters.
|
|
|
|
The Teleinfo binding provides support for both single-phase and three-phase connection, ICC evolution and the following pricing modes:
|
|
|
|
- HCHP mode
|
|
- Base mode
|
|
- Tempo mode
|
|
- EJP mode
|
|
|
|
| Thing type | Connection | Pricing mode | ICC evolution |
|
|
|--------------------------------------------|--------------|--------------|---------------|
|
|
| cbemm_base_electricitymeter | single-phase | Base | |
|
|
| cbemm_ejp_electricitymeter | single-phase | EJP | |
|
|
| cbemm_hc_electricitymeter | single-phase | HCHP | |
|
|
| cbemm_tempo_electricitymeter | single-phase | Tempo | |
|
|
| cbemm_evolution_icc_base_electricitymeter | single-phase | Base | [x] |
|
|
| cbemm_evolution_icc_ejp_electricitymeter | single-phase | EJP | [x] |
|
|
| cbemm_evolution_icc_hc_electricitymeter | single-phase | HCHP | [x] |
|
|
| cbemm_evolution_icc_tempo_electricitymeter | single-phase | Tempo | [x] |
|
|
| cbetm_base_electricitymeter | three-phase | Base | |
|
|
| cbetm_ejp_electricitymeter | three-phase | EJP | |
|
|
| cbetm_hc_electricitymeter | three-phase | HCHP | |
|
|
| cbetm_tempo_electricitymeter | three-phase | Tempo | |
|
|
|
|
### Standard TIC mode
|
|
|
|
Linky telemeters add a new `Standard` mode with more detailed information but still provide information on the legacy format under the `Historical` denomination.
|
|
|
|
Standard mode doesn't depend on the pricing options, but it adds some useful information for electricity producers.
|
|
|
|
| Thing type | Connection | Producer mode |
|
|
|--------------------------------------------|--------------|--------------|
|
|
| lsmm_electricitymeter | single-phase | |
|
|
| lsmm_prod_electricitymeter | single-phase | [x] |
|
|
| lstm_electricitymeter | three-phase | |
|
|
| lstm_prod_electricitymeter | three-phase | [x] |
|
|
|
|
## Discovery
|
|
|
|
Before the binding can be used, a serial controller must be added. This needs to be done manually. Select **Teleinfo Serial Controller** and enter the serial port.
|
|
|
|
If you want to place the Teleinfo modem apart from your openHAB server, you can forward its serial messages over TCP/IP (_ser2net_).
|
|
In this case you have to define the serial port of your Teleinfo modem like this `rfc2217://ip:port`. When using _ser2net_ make sure to use _telnet_ instead of _raw_ in the _ser2net_ config file.
|
|
|
|
Once the serial controller added, electricity meters will automatically appear after starting discovery, with default label **Teleinfo ADCO #adco** where **#adco** is your electricity meter identifier.
|
|
|
|
## Thing Configuration
|
|
|
|
| Thing type | Parameter | Meaning | Possible values |
|
|
|----------------------|--------------|---------------------------------------|---------------------------------|
|
|
| `serialcontroller` | `serialport` | Path to the serial controller | /dev/ttyXXXX, rfc2217://ip:port |
|
|
| | `ticMode` | TIC mode | `STANDARD`, `HISTORICAL` (default) |
|
|
| `*_electricitymeter` | `adco` | Electricity meter identifier | 12 digits number |
|
|
|
|
## Channels
|
|
|
|
### Historical TIC mode
|
|
|
|
Channel availability depends on the electricity connection (single or three-phase) and on the pricing mode (Base, HCHP, EJP or Tempo).
|
|
|
|
| Channel | Type | Description | Connection | Mode |
|
|
|----------|---------------------------|----------------------------------------------------------|--------|-------|
|
|
| isousc | `Number:ElectricCurrent` | Subscribed electric current | All | All |
|
|
| ptec | `String` | Current pricing period | All | All |
|
|
| imax | `Number:ElectricCurrent` | Maximum consumed electric current | Single-phase | All |
|
|
| imax1 | `Number:ElectricCurrent` | Maximum consumed electric current on phase 1 | Three-phase | All |
|
|
| imax2 | `Number:ElectricCurrent` | Maximum consumed electric current on phase 2 | Three-phase | All |
|
|
| imax3 | `Number:ElectricCurrent` | Maximum consumed electric current on phase 3 | Three-phase | All |
|
|
| adps | `Number:ElectricCurrent` | Excess electric current warning | Single-phase | All |
|
|
| adir1 | `Number:ElectricCurrent` | Excess electric current on phase 1 warning | Three-phase | All |
|
|
| adir2 | `Number:ElectricCurrent` | Excess electric current on phase 2 warning | Three-phase | All |
|
|
| adir3 | `Number:ElectricCurrent` | Excess electric current on phase 3 warning | Three-phase | All |
|
|
| iinst | `Number:ElectricCurrent` | Instantaneous electric current | Single-phase | All |
|
|
| iinst1 | `Number:ElectricCurrent` | Instantaneous electric current on phase 1 | Three-phase | All |
|
|
| iinst2 | `Number:ElectricCurrent` | Instantaneous electric current on phase 2 | Three-phase | All |
|
|
| iinst3 | `Number:ElectricCurrent` | Instantaneous electric current on phase 3 | Three-phase | All |
|
|
| ppot | `String` | Electrical potential presence | Three-phase | All |
|
|
| pmax | `Number:Energy` | Maximum consumed electric power on all phases | Three-phase | All |
|
|
| papp | `Number:Power` | Instantaneous apparent power | Three-phase, single-phase (ICC evolution only) | All |
|
|
| hhphc | `String` | Pricing schedule group | All | HCHP |
|
|
| hchc | `Number:Energy` | Total consumed energy at low rate pricing | All | HCHP |
|
|
| hchp | `Number:Energy` | Total consumed energy at high rate pricing | All | HCHP |
|
|
| base | `Number:Energy` | Total consumed energy | All | Base |
|
|
| ejphn | `Number:Energy` | Total consumed energy at low rate pricing | All | EJP |
|
|
| ejphpm | `Number:Energy` | Total consumed energy at high rate pricing | All | EJP |
|
|
| bbrhcjb | `Number:Energy` | Total consumed energy at low rate pricing on blue days | All | Tempo |
|
|
| bbrhpjb | `Number:Energy` | Total consumed energy at high rate pricing on blue days | All | Tempo |
|
|
| bbrhcjw | `Number:Energy` | Total consumed energy at low rate pricing on white days | All | Tempo |
|
|
| bbrhpjw | `Number:Energy` | Total consumed energy at high rate pricing on white days | All | Tempo |
|
|
| bbrhcjr | `Number:Energy` | Total consumed energy at low rate pricing on red days | All | Tempo |
|
|
| bbrhpjr | `Number:Energy` | Total consumed energy at high rate pricing on red days | All | Tempo |
|
|
| pejp | `Number:Time` | Prior notice to EJP start | All | EJP |
|
|
| demain | `String` | Following day color | All | Tempo |
|
|
|
|
### Standard TIC mode
|
|
|
|
#### Common channels
|
|
|
|
The following channels are available on all Linky telemeters in standard TIC mode.
|
|
|
|
| Channel | Type | Description |
|
|
|---------------------------------|---------------------------|-----------------------------------------------------------------------------|
|
|
| commonLSMGroup#ngtf | `String` | Provider schedule name |
|
|
| commonLSMGroup#ltarf | `String` | Current pricing label |
|
|
| commonLSMGroup#east | `Number:Energy` | Total active energy withdrawn |
|
|
| commonLSMGroup#easf_XX_ | `Number:Energy` | Active energy withdrawn from provider on index _XX, XX_ in {01,...,10} |
|
|
| commonLSMGroup#easd_XX_ | `Number:Energy` | Active energy withdrawn from distributor on index _XX, XX_ in {01,...,04} |
|
|
| commonLSMGroup#irms1 | `Number:ElectricCurrent` | RMS Current on phase 1 |
|
|
| commonLSMGroup#urms1 | `Number:Potential` | RMS Voltage on phase 1 |
|
|
| commonLSMGroup#pref | `Number:Power` | Reference apparent power |
|
|
| commonLSMGroup#pcoup | `Number:Power` | Apparent power rupture capacity |
|
|
| commonLSMGroup#sinsts | `Number:Power` | Instantaneous withdrawn apparent power |
|
|
| commonLSMGroup#smaxsn | `Number:Power` | Maximum withdrawn apparent power of the day |
|
|
| commonLSMGroup#smaxsnMinus1 | `Number:Power` | Maximum withdrawn apparent power of the previous day |
|
|
| commonLSMGroup#ccasn | `Number:Power` | Active charge point N |
|
|
| commonLSMGroup#ccasnMinus1 | `Number:Power` | Active charge point N-1 |
|
|
| commonLSMGroup#umoy1 | `Number:Potential` | Mean Voltage on phase 1 |
|
|
| commonLSMGroup#dpm_X_ | `String` | Start of mobile peak period _X, X_ in {1,2,3} |
|
|
| commonLSMGroup#fpm_X_ | `String` | End of mobile peak period _X, X_ in {1,2,3} |
|
|
| commonLSMGroup#msg1 | `String` | Short message |
|
|
| commonLSMGroup#msg2 | `String` | Very short message |
|
|
| commonLSMGroup#ntarf | `String` | Index of current pricing |
|
|
| commonLSMGroup#njourf | `String` | Number of current provider schedule |
|
|
| commonLSMGroup#njourfPlus1 | `String` | Number of next day provider schedule |
|
|
| commonLSMGroup#pjourfPlus1 | `String` | Profile of next day provider schedule |
|
|
| commonLSMGroup#ppointe | `String` | Profile of next rush day |
|
|
| commonLSMGroup#date | `DateTime` | Date and Time |
|
|
| commonLSMGroup#smaxsnDate | `DateTime` | Timestamp of SMAXSN value |
|
|
| commonLSMGroup#smaxsnMinus1Date | `DateTime` | Timestamp of SMAXSN-1 value |
|
|
| commonLSMGroup#ccasnDate | `DateTime` | Timestamp of CCASN value |
|
|
| commonLSMGroup#ccasnMinus1Date | `DateTime` | Timestamp of CCASN-1 value |
|
|
| commonLSMGroup#umoy1Date | `DateTime` | Timestamp of UMOY1 value |
|
|
| commonLSMGroup#dpm_X_Date | `DateTime` | Date of DPM_X_, _X_ in {1,2,3} |
|
|
| commonLSMGroup#fpm_X_Date | `DateTime` | Date of FPM_X_, _X_ in {1,2,3} |
|
|
| commonLSMGroup#relais_X_ | `Switch` | state of relais _X, X_ in {1,...,8} |
|
|
|
|
#### Three phase only channels
|
|
|
|
These channels are available on the following telemeters:
|
|
|
|
- lstm_electricitymeter
|
|
- lsmt_prod_electricitymeter
|
|
|
|
| Channel | Type | Description |
|
|
|-----------------------------------------|---------------------------|-----------------------------------------------------------------------------------|
|
|
| threePhasedLSMGroup#irms_X_ | `Number:ElectricCurrent` | RMS Current on phase _X, X_ in {2,3} |
|
|
| threePhasedLSMGroup#urms_X_ | `Number:Potential` | RMS Voltage on phase _X, X_ in {2,3} |
|
|
| threePhasedLSMGroup#umoy_X_ | `Number:Potential` | Mean Voltage on phase _X, X_ in {2,3} |
|
|
| threePhasedLSMGroup#sinsts_X_ | `Number:Power` | Instantaneous withdrawn apparent power on phase _X, X_ in {1,2,3} |
|
|
| threePhasedLSMGroup#smaxsn_X_ | `Number:Power` | Maximum withdrawn apparent power of the day on phase _X, X_ in {1,2,3} |
|
|
| commonLSMGroup#umoy_X_Date | `DateTime` | Timestamp of UMOY_X_ value, _X_ in {2,3} |
|
|
| threePhasedLSMGroup#smaxsn_X_Minus1 | `Number:Power` | Maximum withdrawn apparent power on the previous day on phase _X, X_ in {1,2,3} |
|
|
| threePhasedLSMGroup#smaxs_X_nDate | `DateTime` | Timestamp of SMAXSN_X_ value, _X_ in {1,2,3} |
|
|
| threePhasedLSMGroup#smaxsn_X_Minus1Date | `DateTime` | Timestamp of SMAXSN_X_-1 value, _X_ in {1,2,3} |
|
|
|
|
#### Producer only channels
|
|
|
|
These channels are available on the following telemeters:
|
|
|
|
- lsmm_prod_electricitymeter
|
|
- lsmt_prod_electricitymeter
|
|
|
|
| Channel | Type | Description |
|
|
|-----------------------------------|-----------------|----------------------------------------------------------|
|
|
| producerLSMGroup#eait | `Number:Energy` | Total active energy injected |
|
|
| producerLSMGroup#erq_X_ | `Number:Energy` | Total reactive energy on index _X, X_ in {1,...,4} |
|
|
| producerLSMGroup#sinsti | `Number:Energy` | Instantaneous injected apparent power |
|
|
| producerLSMGroup#smaxin | `Number:Power` | Maximum injected apparent power of the day |
|
|
| producerLSMGroup#smaxinMinus1 | `Number:Power` | Maximum injected apparent power of the previous day |
|
|
| producerLSMGroup#ccain | `Number:Power` | Injected active charge point N |
|
|
| producerLSMGroup#ccainMinus1 | `Number:Power` | Injected active charge point N-1 |
|
|
| producerLSMGroup#smaxinDate | `DateTime` | Timestamp of SMAXIN value |
|
|
| producerLSMGroup#smaxinMinus1Date | `DateTime` | Timestamp of SMAXIN-1 value |
|
|
| producerLSMGroup#ccainDate | `DateTime` | Timestamp of CCAIN value |
|
|
| producerLSMGroup#ccainMinus1Date | `DateTime` | Timestamp of CCAIN-1 value |
|
|
|
|
## Full Example
|
|
|
|
### Historical TIC mode
|
|
|
|
The following `things` file declare a serial USB controller on `/dev/ttyUSB0` for a Single-phase Electricity meter with HC/HP option - CBEMM Evolution ICC and adco `031528042289`:
|
|
|
|
```java
|
|
Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0" ]{
|
|
Thing cbemm_evolution_icc_hc_electricitymeter myElectricityMeter [ adco="031528042289"]
|
|
}
|
|
```
|
|
|
|
`adco` is a 12-digit number written on the electricity meter (There might be two additional digits on the electricity meter, in this case the two last digits must be omitted to obtain 12 digits). The first 6 digits of `adco` can also be retrieved by pushing 6 times the `selection` button of your electricity meter, and the last 6 digits by pushing the `defilement` button.
|
|
|
|
This `items` file links some supported channels to items:
|
|
|
|
```java
|
|
Number:Power TLInfoEDF_PAPP "PAPP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:papp"}
|
|
Number:ElectricCurrent TLInfoEDF_ISOUSC "ISOUSC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:isousc"}
|
|
String TLInfoEDF_PTEC "PTEC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:ptec"}
|
|
Number:ElectricCurrent TLInfoEDF_IMAX "IMAX" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:imax"}
|
|
Number:ElectricCurrent TLInfoEDF_ADPS "ADPS" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:adps"}
|
|
Number:ElectricCurrent TLInfoEDF_IINST "IINST" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:iinst"}
|
|
Number:Energy TLInfoEDF_HCHC "HCHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchc"}
|
|
Number:Energy TLInfoEDF_HCHP "HCHP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchp"}
|
|
String TLInfoEDF_HHPHC "HHPHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hhphc"}
|
|
```
|
|
|
|
### Standard TIC mode
|
|
|
|
The following `things` file declare a serial USB controller on `/dev/ttyUSB0` for a Linky Single-phase Electricity meter in standard TIC mode and adsc `031528042289`:
|
|
|
|
```java
|
|
Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0", ticMode="STANDARD" ]{
|
|
Thing lsmm_electricitymeter myElectricityMeter [ adco="031528042289"]
|
|
}
|
|
```
|
|
|
|
This `items` file links some supported channels to items:
|
|
|
|
```java
|
|
Number:Power TLInfoEDF_SINSTS "SINSTS" <energy> ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#sinsts"}
|
|
Number:ElectricCurrent TLInfoEDF_PREF "PREF" <energy> ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#pref"}
|
|
String TLInfoEDF_LTARF "LTARF" <energy> ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ltarf"}
|
|
Number:ElectricCurrent TLInfoEDF_SMAXSN "SMAXSN" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsn"}
|
|
Number:ElectricCurrent TLInfoEDF_IRMS1 "IRMS1" <energy> ["Measurement","Current"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#irms1"}
|
|
Number:Energy TLInfoEDF_EASF01 "EASF01" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf01"}
|
|
Number:Energy TLInfoEDF_EASF02 "EASF02" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf02"}
|
|
String TLInfoEDF_NGTF "NGTF" <energy> ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ngtf"}
|
|
DateTime TLInfoEDF_SMAXSN_DATE "SMAXSN_DATE" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsnDate"}
|
|
```
|
|
|
|
## Tested hardware
|
|
|
|
The Teleinfo binding has been successfully validated with below hardware configuration:
|
|
|
|
| Serial interface | Power Energy Meter model | Mode(s) | TIC mode |
|
|
|------------------|-----------------------------|---------------------------|----------|
|
|
| GCE Electronics USB Teleinfo module [(more details)](https://gce-electronics.com/fr/usb/655-module-teleinfo-usb.html) | Actaris A14C5 | Single-phase HCHP & Base | Historical |
|
|
| Cartelectronic USB Teleinfo modem [(more details)](https://www.cartelectronic.fr/teleinfo-compteur-enedis/17-teleinfo-1-compteur-usb-rail-din-3760313520028.html) | Sagem S10C4 | Single-phase HCHP | Historical |
|
|
| GCE Electronics USB Teleinfo module [(more details)](https://gce-electronics.com/fr/usb/655-module-teleinfo-usb.html) | Linky | Single-phase HCHP | Standard |
|
|
| Cartelectronic USB Teleinfo modem [(more details)](https://www.cartelectronic.fr/teleinfo-compteur-enedis/17-teleinfo-1-compteur-usb-rail-din-3760313520028.html) | Linky | Three-phase TEMPO | Standard |
|
|
|
|
The method for changing the TIC mode of a Linky telemeter is explained [here](https://forum.gce-electronics.com/t/comment-passer-un-cpt-linky-en-mode-standard/8206/7).
|