# RegoHeatPump Binding
|
|
|
|
The Rego heat pump binding supports:
|
|
|
|
- Rego 6xx controllers family and
|
|
- Husdata interface.
|
|
|
|
## The Rego 6xx family
|
|
|
|
The Rego 6xx controllers family is used in many heat pumps such as IVT/Bosch/Autotherm/Carrier and others.
|
|
|
|
Rego 6xx unit contain an interface marked as service.
|
|
Header of this interface is close to the control unit. This is 5V (TTL) serial interface and is connected by a 9 pin can/d-sub connector. Pinout:
|
|
|
|
2 - RxD
|
|
3 - TxD
|
|
4 - +5V
|
|
5 - GND
|
|
|
|
Serial communication is using 19200 bps, 8 bit, no parity, 1 stop bit.
|
|
|
|
### Thing configuration
|
|
|
|
Two connection types are supported:
|
|
|
|
- TCP/IP and
|
|
- serial (RS232).
|
|
|
|
#### TCP/IP connection
|
|
|
|
A transparent bridge between the serial interface of the heat pump and network (i.e. wifi) is used.
|
|
This way no additional wires are required between heat pump and computer, running openHAB.
|
|
|
|
There are many existing project providing such functionality, i.e. [ser2net](http://ser2net.sourceforge.net/).
|
|
|
|
For my setup, I used a low budget (~5€) circuit, that is integrated into the heat pump and connects to a wifi using an ESP8266 based module.
|
|
|
|
Board:
|
|
|
|
![board](doc/board.png)
|
|
|
|
The code running on the ESP module can be found [here](https://github.com/crnjan/esp8266-bridge).
|
|
There are other projects providing ESP firmware with similar functionality, i.e. [ESP-LINK](https://github.com/jeelabs/esp-link), but did not test with those.
|
|
|
|
Configuration of the TCP/IP thing:
|
|
|
|
- address: the hostname/IP address of the transparent bridge on the local network - mandatory,
|
|
- tcpPort: the port number to use to connect to the transparent bridge - optional, defaults to 9265,
|
|
- refreshInterval: refresh interval in seconds, used to fetch new values from the heat pump - optional, defaults to 60 seconds.
|
|
|
|
Example thing definition:
|
|
|
|
```java
|
|
regoheatpump:ipRego6xx:ivtIP [ address="192.168.2.50", tcpPort="9265" ]
|
|
```
|
|
|
|
#### Serial connection
|
|
|
|
In order to connect directly to the rego 6xx controller, one needs to adjust the TTL levels coming from the rego unit to levels used by a RS232 serial port, used within computers, using MAX232 or similar.
|
|
|
|
Parameters:
|
|
|
|
- portName: the name of the serial port on your computer - mandatory,
|
|
- refreshInterval: refresh interval in seconds, used to fetch new values from the heat pump - optional, defaults to 60 seconds.
|
|
|
|
Example thing definition:
|
|
|
|
```java
|
|
regoheatpump:serialRego6xx:ivtSerial [ portName="COM3" ]
|
|
```
|
|
|
|
### Channels
|
|
|
|
Below is the list of supported channels:
|
|
|
|
| Channel Type ID | Item Type | Access |
|
|
|---------------------------------------|-------------|--------|
|
|
| sensorValues#radiatorReturn | Temperature | R |
|
|
| sensorValues#outdoor | Temperature | R |
|
|
| sensorValues#hotWater | Temperature | R |
|
|
| sensors#radiatorForward | Temperature | R |
|
|
| sensorValues#indoor | Temperature | R |
|
|
| sensorValues#compressor | Temperature | R |
|
|
| sensorValues#heatFluidOut | Temperature | R |
|
|
| sensorValues#heatFluidIn | Temperature | R |
|
|
| sensorValues#coldFluidIn | Temperature | R |
|
|
| sensorValues#coldFluidOut | Temperature | R |
|
|
| sensorValues#externalHotWater | Temperature | R |
|
|
| status#lastErrorTimestamp | DateTime | R |
|
|
| status#lastErrorType | String | R |
|
|
| frontPanel#powerLamp | Switch | R |
|
|
| frontPanel#heatPumpLamp | Switch | R |
|
|
| frontPanel#additionalHeatLamp | Switch | R |
|
|
| frontPanel#hotWaterLamp | Switch | R |
|
|
| frontPanel#alarmLamp | Switch | R |
|
|
| controlData#radiatorReturnTarget | Temperature | R |
|
|
| controlData#radiatorReturnOn | Temperature | R |
|
|
| controlData#radiatorReturnOff | Temperature | R |
|
|
| controlData#hotWaterOn | Temperature | R |
|
|
| controlData#hotWaterOff | Temperature | R |
|
|
| controlData#radiatorForwardTarget | Temperature | R |
|
|
| controlData#addHeatPower | Number (%) | R |
|
|
| deviceValues#coldFluidPump | Switch | R |
|
|
| deviceValues#compressor | Switch | R |
|
|
| deviceValues#additionalHeat3kW | Switch | R |
|
|
| deviceValues#additionalHeat6kW | Switch | R |
|
|
| deviceValues#radiatorPump | Switch | R |
|
|
| deviceValues#heatFluidPump | Switch | R |
|
|
| deviceValues#switchValue | Switch | R |
|
|
| deviceValues#alarm | Switch | R |
|
|
| settings#hotWaterTarget | Temperature | RW |
|
|
| settings#hotWaterTargetHysteresis | Temperature | RW |
|
|
| settings#heatCurve | Number | RW |
|
|
| settings#heatCurveFineAdj | Temperature | RW |
|
|
| settings#heatCurve2 | Number | RW |
|
|
| settings#heatCurve2FineAdj | Temperature | RW |
|
|
| settings#indoorTempSetting | Temperature | RW |
|
|
| settings#curveInflByInTemp | Number | RW |
|
|
| settings#adjCurveAt20 | Temperature | RW |
|
|
| settings#adjCurveAt15 | Temperature | RW |
|
|
| settings#adjCurveAt10 | Temperature | RW |
|
|
| settings#adjCurveAt5 | Temperature | RW |
|
|
| settings#adjCurveAt0 | Temperature | RW |
|
|
| settings#adjCurveAtMinus5 | Temperature | RW |
|
|
| settings#adjCurveAtMinus10 | Temperature | RW |
|
|
| settings#adjCurveAtMinus15 | Temperature | RW |
|
|
| settings#adjCurveAtMinus20 | Temperature | RW |
|
|
| settings#adjCurveAtMinus25 | Temperature | RW |
|
|
| settings#adjCurveAtMinus30 | Temperature | RW |
|
|
| settings#adjCurveAtMinus35 | Temperature | RW |
|
|
| settings#heatCurveCouplingDiff | Temperature | RW |
|
|
| settings#summerDisconnection | Temperature | RW |
|
|
| operatingTimes#heatPumpInOperationRAD | Hours | R |
|
|
| operatingTimes#heatPumpInOperationDHW | Hours | R |
|
|
| operatingTimes#addHeatInOperationRAD | Hours | R |
|
|
| operatingTimes#addHeatInOperationDHW | Hours | R |
|
|
|
|
Access: R = read only; RW = read write
|
|
|
|
**Note - breaking change:** to have all writable channels within the settings group, hotWaterTarget channel was moved from controlData to the setting group.
|
|
|
|
## The Husdata interface
|
|
|
|
The [Husdata](https://www.husdata.se/) interface bridges the often complex communication methods with a heat pump controller and provides access through a simple standard interface over RS-232.
|
|
|
|
Supported heat pump models
|
|
|
|
| Heat pump models | Technical |
|
|
|-----------------------------------|--------------------|
|
|
| IVT Greenline / Optima 900 | Rego 600 Serial |
|
|
| IVT 490 | Rego 400 Serial |
|
|
| IVT Premiumline X, Optima/290-AW | Rego 800, Can bus |
|
|
| IVT Greenline HE/HC/HA+Prem HQ/EQ | Rego 1000, Can bus |
|
|
| NIBE xx45 | EB100, RS-485 |
|
|
| NIBE Fighter series | Styr 2002, RS-485 |
|
|
| Thermia Diplomat series | 901510, i2c |
|
|
|
|
Above list is informational, please consult with the Husdata interface provider for further details.
|
|
|
|
### Thing configuration
|
|
|
|
Two connection types are supported:
|
|
|
|
- TCP/IP and
|
|
- serial (RS232).
|
|
|
|
#### TCP/IP connection
|
|
|
|
A transparent bridge between the Husdata interface and network (i.e. wifi) is used.
|
|
|
|
There are many existing project providing such functionality, i.e. [ser2net](http://ser2net.sourceforge.net/).
|
|
|
|
Configuration of the TCP/IP thing:
|
|
|
|
- address: the hostname/IP address of the transparent bridge on the local network - mandatory,
|
|
- tcpPort: the port number to use to connect to the transparent bridge - optional, defaults to 9265.
|
|
|
|
Example thing definition:
|
|
|
|
```java
|
|
regoheatpump:ipHusdata:ivtIP [ address="192.168.2.50", tcpPort="9265" ]
|
|
```
|
|
|
|
#### Serial connection
|
|
|
|
One can connect the Husdata interface directly to a computer that runs openHAB.
|
|
|
|
Parameters:
|
|
|
|
- portName: the name of the serial port on your computer - mandatory.
|
|
|
|
Example thing definition:
|
|
|
|
```java
|
|
regoheatpump:serialHusdata:ivtSerial [ portName="COM3" ]
|
|
```
|
|
|
|
### Channels
|
|
|
|
Below is the list of supported channels, all values are read only:
|
|
|
|
| H1 ID | Name | Channel Type ID | Item Type |
|
|
|-------|-----------------------|----------------------------------|------------------|
|
|
| 001 | Radiator Return | sensorValues#radiatorReturn | Temperature |
|
|
| 002 | Radiator Forward | sensorValues#radiatorForward | Temperature |
|
|
| 003 | Heat carrier Return | sensorValues#heatFluidIn | Temperature |
|
|
| 004 | Heat carrier Forward | sensorValues#heatFluidOut | Temperature |
|
|
| 005 | Brine In / Evaporator | sensorValues#coldFluidIn | Temperature |
|
|
| 006 | Brine Out / Condenser | sensorValues#coldFluidOut | Temperature |
|
|
| 007 | Outdoor | sensorValues#outdoor | Temperature |
|
|
| 008 | Indoor | sensorValues#indoor | Temperature |
|
|
| 009 | Hot water 1 / Top | sensorValues#hotWater | Temperature |
|
|
| 00A | Hot water 2 / Mid | sensorValues#externalHotWater | Temperature |
|
|
| 00B | Hot gas / Compressor | sensorValues#compressor | Temperature |
|
|
| 00E | Air intake | sensorValues#airIntake | Temperature |
|
|
| 011 | Pool | sensorValues#pool | Temperature |
|
|
| 104 | Add heat status | controlData#addHeatPowerPercent | Number - % |
|
|
| 104 | Add heat status | controlData#addHeatPowerEnergy | Number - kW |
|
|
| 107 | Heating setpoint | controlData#radiatorReturnTarget | Temperature |
|
|
| 108 | Compressor speed | controlData#compressorSpeed | Number - % |
|
|
| 203 | Room temp setpoint | settings#indoorTempSetting | Temperature |
|
|
| 204 | Room sensor influence | settings#curveInflByInTemp | Number |
|
|
| 205 | Heat set 1, CurveL | settings#heatCurve | Number |
|
|
| 206 | Heat set 2, CurveR | settings#heatCurve2 | Number |
|
|
| A01 | Compressor | deviceValues#compressor | Switch |
|
|
| A04 | Pump Cold circuit | deviceValues#coldFluidPump | Switch |
|
|
| A05 | Pump Heat circuit | deviceValues#heatFluidPump | Switch |
|
|
| A06 | Pump Radiator | deviceValues#radiatorPump | Switch |
|
|
| A07 | Switch valve 1 | deviceValues#switchValve | Switch |
|
|
| A08 | Switch valve 2 | deviceValues#switchValve2 | Switch |
|
|
| A09 | Fan | deviceValues#fan | Switch |
|
|
| A0A | High Pressostat | deviceValues#highPressostat | Switch |
|
|
| A0B | Low Pressostat | deviceValues#lowPressostat | Switch |
|
|
| A0C | Heating cable | deviceValues#heatingCable | Switch |
|
|
| A0D | Crank case heater | deviceValues#crankCaseHeater | Switch |
|
|
| A20 | Alarm | deviceValues#alarm | Switch |
|
|
| FF1 | EL-Meter 1 | deviceValues#elMeter1 | Number - pulses |
|
|
| FF2 | EL-Meter 2 | deviceValues#elMeter2 | Number - pulses |
|