# ProteusEcoMeter Binding
|
|
|
|
This is the binding for the Proteus EcoMeter S, which is able to report the level of a cistern or tank.
|
|
|
|
Note that this binding currently supports no write channels.
|
|
This means you have to configure your sensor by considering the manual of the product (using wireless display).
|
|
After doing that the binding comes into play and helps you to get your measured values into openHAB.
|
|
Please be patient while waiting for the first received data.
|
|
The sensor reports at an interval of approx. 1h, except when the water level changes relatively fast.
|
|
|
|
## Supported Things
|
|
|
|
Proteus EcoMeter S.
|
|
The binding has been tested with this EcoMeter sensor only.
|
|
|
|
## Discovery
|
|
|
|
No auto discovery implemented yet.
|
|
|
|
## Thing Configuration
|
|
|
|
Plug the wireless display into an USB port.
|
|
Note [openHAB Serial Port documentation](https://www.openhab.org/docs/administration/serial.html) for general serial port configuration.
|
|
After that you can add the device as thing and configure the usbPort your OS generated for the display.
|
|
|
|
```text
|
|
UID: proteusecometer:EcoMeterS:e90705eaa4
|
|
label: Proteus EcoMeter S
|
|
thingTypeUID: proteusecometer:EcoMeterS
|
|
configuration:
|
|
usbPort: /dev/ttyUSB0
|
|
```
|
|
|
|
## Channels
|
|
|
|
| channel | type | description |
|
|
|-----------------------|----------------------|------------------------------------------------------|
|
|
| temperature | Number:Temperature | Temperature measured by the sensor |
|
|
| sensorLevel | Number:Length | Distance between sensor and water surface |
|
|
| usableLevel | Number:Volume | How much liquid is usable |
|
|
| usableLevelInPercent | Number:Dimensionless | How much liquid is usable relative to total capacity |
|
|
| totalCapacity | Number:Volume | Total capacity of measured cistern/tank |
|
|
|
|
## Full Example
|
|
|
|
Thing proteusecometer:EcoMeterS:e90705eaa4 "Proteus EcoMeter S" [ usbPort="/dev/ttyUSB0" ]
|
|
|
|
Number:Temperature Temperature "Measured temperature [%.1f °C]" { channel="proteusecometer:EcoMeterS:e90705eaa4:temperature" }
|
|
Number:Length SensorLevelCm "Sensor Level" { channel="proteusecometer:EcoMeterS:e90705eaa4:sensorLevel" }
|
|
Number:Volume UsableLevel "Usable Level" { channel="proteusecometer:EcoMeterS:e90705eaa4:usableLevel" }
|
|
Number:Dimensionless UsableLevelinpercent "Usable Level" { channel="proteusecometer:EcoMeterS:e90705eaa4:usableLevelInPercent" }
|
|
Number:Volume TotalCapacityinliter "Total Capacity" { channel="proteusecometer:EcoMeterS:e90705eaa4:totalCapacity" }
|