# GROHE ONDUS Binding
|
|
|
|
The GROHE ONDUS Binding provides access to data collected by a GROHE ONDUS appliance, such as an [GROHE Sense Guard](https://www.grohe.de/de_de/smarthome/grohe-sense-guard/).
|
|
The binding uses the REST API interface (the same as used by the Android App) to retrieve the collected data.
|
|
|
|
## Supported Things
|
|
|
|
This binding should support all appliances from GROHE, however, only the GROHE Sense and Sense Guard is tested with it.
|
|
|
|
| Thing type | Name |
|
|
|--------------------------|--------------------------|
|
|
| account | GROHE ONDUS Account |
|
|
| senseguard | GROHE SENSE Guard device |
|
|
| sense | GROHE SENSE device |
|
|
|
|
## Discovery
|
|
|
|
The binding requires you to create at least one Account thing as a bridge manually.
|
|
The discovery process will look through all locations and rooms of your configured GROHE account and adds each found appliance as a new thing automatically to the inbox.
|
|
|
|
## Binding Configuration
|
|
|
|
This binding does not require any configuration outside of things.
|
|
|
|
## Thing Configuration
|
|
|
|
There is only one thing and one bridge that needs to be configured together to get this binding to work, see the full example section for a self-explaining example.
|
|
|
|
### Account Bridge
|
|
|
|
The `groheondus:account` bridge is used to configure the API interface for a specific account, which is used to access the collected and saved data of your GROHE account.
|
|
Use the same credentials as in the mobile app.
|
|
|
|
### Appliance
|
|
|
|
The `groheondus:sense` and `groheondus:senseguard` things are used to retrieve information of a specific appliance from GROHE.
|
|
This appliance needs to be connected with your GROHE ONDUS account as configured in the corresponding Account Bridge.
|
|
The appliance needs to be configured with the unique appliance ID (with the `applianceId` configuration) as well as the `roomId` and the `locationId`.
|
|
Once the account bridge is configured, the appliances in your account will be discovered as Appliance things.
|
|
`pollingInterval` has a minimum value of 900 seconds to avoid service rate limiting.
|
|
|
|
| Configuration | Default value | Description |
|
|
|--------------------------|--------------------------|-------------------------------------------------------|
|
|
| applianceId | '' | Unique ID of the appliance in the GROHE ONDUS account |
|
|
| roomId | '' | ID of the room the appliance is in |
|
|
| locationId | '' | ID of the location (building) the appliance is in |
|
|
| pollingInterval | Retrieved from API, | Interval in seconds to get new data from the API |
|
|
| | usually 900 | The `sense` thing uses 900 by default. |
|
|
|
|
#### Channels
|
|
|
|
##### senseguard
|
|
|
|
| Channel | Type | Description |
|
|
|---------------------------------|--------------------|--------------------------------------------------|
|
|
| name | String | The name of the appliance |
|
|
| pressure | Number:Pressure | The pressure of your water supply |
|
|
| temperature_guard | Number:Temperature | The ambient temperature of the appliance |
|
|
| valve_open | Switch | Valve switch |
|
|
| waterconsumption | Number:Volume | The amount of water used in a specific timeframe |
|
|
| waterconsumption_since_midnight | Number:Volume | The amount of water used since midnight |
|
|
|
|
##### sense
|
|
|
|
| Channel | Type | Description |
|
|
|--------------------------|--------------------------|-------------------------------------------------------|
|
|
| name | String | The name of the appliance |
|
|
| humidity | Number:Dimensionless | The humidity measured by the appliance |
|
|
| temperature | Number:Temperature | The ambient temperature of the appliance |
|
|
| battery | Number | The battery level of the appliance |
|
|
|
|
Note: Be aware that the Sense reports data once a day (at most), and that the value posted in the channel - however the latest - may be up to 48 hours old.
|
|
|
|
## Full Example
|
|
|
|
Things file:
|
|
|
|
```java
|
|
Bridge groheondus:account:account1 [ username="user@example.com", password="YourStrongPasswordHere!" ] {
|
|
groheondus:senseguard:550e8400-e29b-11d4-a716-446655440000 [ applianceId="550e8400-e29b-11d4-a716-446655440000", roomId=456, locationId=123 ] {
|
|
Channels:
|
|
Type number : waterconsumption [
|
|
timeframe=3
|
|
]
|
|
}
|
|
groheondus:sense:550e8400-e29b-11d4-a716-446655440000 [ applianceId="444e8400-e29b-11d4-a716-446655440000", roomId=456, locationId=123 ]
|
|
}
|
|
```
|
|
|
|
Items file:
|
|
|
|
```java
|
|
String Name_Sense_Guard "Appliance Name" {channel="groheondus:senseguard:groheondus:appliance:550e8400-e29b-11d4-a716-446655440000:name"}
|
|
Number:Pressure Pressure_Sense_Guard "Pressure [%.1f %unit%]" {channel="groheondus:senseguard:groheondus:appliance:550e8400-e29b-11d4-a716-446655440000:pressure"}
|
|
Number:Temperature Temperature_Sense_Guard "Temperature [%.1f %unit%]" {channel="groheondus:senseguard:groheondus:appliance:550e8400-e29b-11d4-a716-446655440000:temperature_guard"}
|
|
Number:Volume Water_Usage_Since_Midnight_Sense_Guard "Water usage since midnight [%.1f %unit%]" {channel="groheondus:senseguard:groheondus:appliance:550e8400-e29b-11d4-a716-446655440000:waterconsumption_since_midnight"}
|
|
|
|
String Name_Sense "Temperature [%.1f %unit%]" {channel="groheondus:sense:groheondus:appliance:444e8400-e29b-11d4-a716-446655440000:name"}
|
|
Number:Temperature Temperature_Sense "Temperature [%.1f %unit%]" {channel="groheondus:sense:groheondus:appliance:444e8400-e29b-11d4-a716-446655440000:temperature"}
|
|
Number Humidity_Sense "Humidity [%.1f %unit%]" {channel="groheondus:sense:groheondus:appliance:444e8400-e29b-11d4-a716-446655440000:humidity"}
|
|
```
|