# Enphase Binding
|
|
|
|
This is the binding for the [Enphase](https://enphase.com/) Envoy Solar Panel gateway.
|
|
The binding uses the local API of the Envoy gateway.
|
|
Some calls can be made without authentication and some use a user name and password.
|
|
The default user name is `envoy` and the default password is the last 6 numbers of the serial number.
|
|
The Envoy gateway updates the data every 5 minutes.
|
|
Therefore using a refresh rate shorter doesn't provide more information.
|
|
|
|
## Supported Things
|
|
|
|
The follow things are supported:
|
|
|
|
- `envoy` The Envoy gateway thing, which is a bridge thing.
|
|
- `inverter` An Enphase micro inverter connected to a solar panel.
|
|
- `relay` An Enphase relay.
|
|
|
|
Not all Envoy gateways support all channels and things.
|
|
Therefore some data on inverters and the relay may not be available.
|
|
The binding auto detects which data is available and will report this in the log on initialization of the gateway bridge.
|
|
|
|
## Discovery
|
|
|
|
The binding can discover Envoy gateways, micro inverters and relays.
|
|
If login access is needed the Bridge `envoy` needs to be configured after discovering and adding before other things can be discovered.
|
|
In that case, after configuring the login, run discovery again.
|
|
|
|
## Thing Configuration
|
|
|
|
### Bridge configuration
|
|
|
|
Depending on the software version of the Envoy gateway thing `envoy` there are different configuration options needed.
|
|
Newer versions of the Envoy software (> version 7) require a different authentication method.
|
|
Because the configuration is different, different bridge things are available.
|
|
|
|
The following options are relevant for all envoy versions:
|
|
|
|
| parameter | required | description |
|
|
|--------------|----------|-------------------------------------------------------------------------------------------------------------|
|
|
| serialNumber | yes | The serial number of the Envoy gateway which can be found on the gateway |
|
|
| hostname | no | The host name/ip address of the Envoy gateway. Leave empty to auto detect |
|
|
| refresh | no | Period between data updates. The default is the same 5 minutes the data is actually refreshed on the Envoy |
|
|
|
|
#### Envoy below version 7
|
|
|
|
For Envoy versions below 7 has the following authentication configuration options are relevant:
|
|
|
|
| parameter | required | description |
|
|
|--------------|----------|-------------------------------------------------------------------------------------------------------------|
|
|
| username | no | The user name to the Envoy gateway. Leave empty when using the default user name |
|
|
| password | no | The password to the Envoy gateway. Leave empty when using the default password |
|
|
|
|
#### Envoy from version 7
|
|
|
|
For Envoy versions 7 and newer has the following authentication configuration options are relevant:
|
|
|
|
| parameter | required | description |
|
|
|--------------|----------|-------------------------------------------------------------------------------------------------------------|
|
|
| autoJwt | yes | Specify if the JWT access token should be obtained by logging in or if the jwt is provided manually |
|
|
| username | yes/no | The user name to the Entrez server. Required if auto Jwt is true |
|
|
| password | yes/no | The password to the Entrez server. Required if auto Jwt is true |
|
|
| siteName | yes/no | The name of the site. Can be found above the Site Id in the Enphase app. Required when autoJwt is true |
|
|
| jwt | yes/no | The jwt is required if autoJWT is false, if it's true jwt is not used |
|
|
|
|
### Thing configuration
|
|
|
|
The micro inverter `inverter` and `relay` things have only 1 parameter:
|
|
|
|
| parameter | required | description |
|
|
|--------------|----------|-----------------------------------|
|
|
| serialNumber | yes | The serial number of the inverter |
|
|
|
|
## Channels
|
|
|
|
The `envoy` thing has can show both production as well as consumption data.
|
|
There are channel groups for `production` and `consumption` data.
|
|
The `consumption` data is only available if the gateway reports this.
|
|
An example of a production channel name is: `production#wattsNow`.
|
|
|
|
| channel | type | description |
|
|
|--------------------|---------------|---------------------------------------|
|
|
| wattHoursToday | Number:Energy | Watt hours produced today |
|
|
| wattHoursSevenDays | Number:Energy | Watt hours produced the last 7 days |
|
|
| wattHoursLifetime | Number:Energy | Watt hours produced over the lifetime |
|
|
| wattsNow | Number:Power | Latest watts produced |
|
|
|
|
The `inverter` thing has the following channels:
|
|
|
|
| channel | type | description |
|
|
|-----------------|--------------|--------------------------------------|
|
|
| lastReportWatts | Number:Power | Last reported power delivery |
|
|
| maxReportWatts | Number:Power | Maximum reported power |
|
|
| lastReportDate | DateTime | Date of last reported power delivery |
|
|
|
|
The following channels are only available if supported by the Envoy gateway:
|
|
|
|
The `relay` thing has the following channels:
|
|
|
|
| channel | type | description |
|
|
|-----------------|--------------|--------------------------------------------------------|
|
|
| relay | Contact | Status of the relay. |
|
|
| line1Connected | Contact | If power line 1 is connected. If closed it's connected |
|
|
| line2Connected | Contact | If power line 2 is connected. If closed it's connected |
|
|
| line2Connected | Contact | If power line 3 is connected. If closed it's connected |
|
|
|
|
The `inverter` and `relay` have the following additional advanced channels:
|
|
|
|
| channel | type | description |
|
|
|-----------------|--------------------|--------------------------------------|
|
|
| producing | Switch (Read Only) | If the device is producing |
|
|
| communicating | Switch (Read Only) | If the device is communicating |
|
|
| provisioned | Switch (Read Only) | If the device is provisioned |
|
|
| operating | Switch (Read Only) | If the device is operating |
|
|
|
|
## Full Example
|
|
|
|
Things example:
|
|
|
|
```java
|
|
Bridge enphase:envoy:789012 "Envoy" [ serialNumber="12345789012" ] {
|
|
Things:
|
|
inverter 123456 "Enphase Inverter 123456" [ serialNumber="789012123456" ]
|
|
inverter 223456 "Enphase Inverter 223456" [ serialNumber="789012223456" ]
|
|
}
|
|
```
|
|
|
|
Items example:
|
|
|
|
```java
|
|
Number:Power envoyWattsNow "Watts Now [%d %unit%]" { channel="enphase:envoy:789012:production#wattsNow" }
|
|
Number:Energy envoyWattHoursToday "Watt Hours Today [%d %unit%]" { channel="enphase:envoy:789012:production#wattHoursToday" }
|
|
Number:Energy envoyWattHours7Days "Watt Hours 7 Days [%.1f kWh]" { channel="enphase:envoy:789012:production#wattHoursSevenDays" }
|
|
Number:Energy envoyWattHoursLifetime "Watt Hours Lifetime [%.1f kWh]" { channel="enphase:envoy:789012:production#wattHoursLifetime" }
|
|
|
|
Number:Power i1LastReportWatts "Last Report [%d %unit%]" { channel="enphase:inverter:789012:123456:lastReportWatts" }
|
|
Number:Power i1MaxReportWatts "Max Report [%d %unit%]" { channel="enphase:inverter:789012:123456:maxReportWatts" }
|
|
DateTime i1LastReportDate "Last Report Date [%1$tY-%1$tm-%1$td %1$tH:%1$tM]" { channel="enphase:inverter:789012:123456:lastReportDate" }
|
|
|
|
Number:Power i2LastReportWatts "Last Report [%d %unit%]" { channel="enphase:inverter:789012:223456:lastReportWatts" }
|
|
Number:Power i21MaxReportWatts "Max Report [%d %unit%]" { channel="enphase:inverter:789012:223456:maxReportWatts" }
|
|
DateTime i2LastReportDate "Last Report Date [%1$tY-%1$tm-%1$td %1$tH:%1$tM]" { channel="enphase:inverter:789012:223456:lastReportDate" }
|
|
```
|