# Fronius Binding
|
|
|
|
This binding uses the [Fronius Solar API V1](https://www.fronius.com/en/solar-energy/installers-partners/technical-data/all-products/system-monitoring/open-interfaces/fronius-solar-api-json-) to obtain data from Fronius devices.
|
|
|
|
It supports Fronius inverters, smart meters and Ohmpilot devices connected to a Fronius Datamanager 1.0 / 2.0, Fronius Datalogger or with integrated Solar API V1 support.
|
|
|
|
Inverters with integrated Solar API V1 support include:
|
|
|
|
- Fronius Galvo
|
|
- Fronius Primo
|
|
- Fronius Symo
|
|
- Fronius Symo Gen24
|
|
- Fronius Symo Gen24 Plus
|
|
|
|
## Supported Things
|
|
|
|
| Thing Type | Description |
|
|
|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
|
| `bridge` | The Bridge |
|
|
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters: You can add multiple inverters that depend on the same datalogger with different device ids. (default id = 1) |
|
|
| `meter` | Fronius Smart Meter: You can add multiple smart meters with different device ids. (default id = 0) |
|
|
| `ohmpilot` | Fronius Ohmpilot ( default id = 0) |
|
|
|
|
## Discovery
|
|
|
|
There is no discovery implemented. You have to create your Things manually and specify the hostname or IP address of the Datalogger and the device id.
|
|
|
|
## Binding Configuration
|
|
|
|
The binding has no configuration options, all configuration is done at `bridge`, `powerinverter`, `meter` or `ohmpilot` level.
|
|
|
|
## Thing Configuration
|
|
|
|
### Bridge Thing Configuration
|
|
|
|
| Parameter | Description | Required |
|
|
|-------------------|--------------------------------------------------------------------------------|----------|
|
|
| `hostname` | The hostname or IP address of your Fronius Datamanager, Datalogger or inverter | Yes |
|
|
| `username` | The username to authenticate with the inverter settings for battery control | No |
|
|
| `password` | The password to authenticate with the inverter settings for battery control | No |
|
|
| `refreshInterval` | Refresh interval in seconds | No |
|
|
|
|
### Powerinverter Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | ------------------------------------------ |
|
|
| `deviceId` | The identifier of your device (Default: 1) |
|
|
|
|
### Meter Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | ----------------------------------------------- |
|
|
| `deviceId` | The identifier of your smart meter (Default: 0) |
|
|
|
|
### Ohmpilot Thing Configuration
|
|
|
|
| Parameter | Description |
|
|
| ---------- | -------------------------------------------- |
|
|
| `deviceId` | The identifier of your ohmpilot (Default: 0) |
|
|
|
|
## Channels
|
|
|
|
### `powerinverter` Thing Channels
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ------------------------------------ | ------------------------ | ----------------------------------------------------------------------------------------------------------------- |
|
|
| `inverterdatachannelpac` | Number:Power | AC Power generated |
|
|
| `inverterdatachannelpdc` | Number:Power | DC Power calculated from DC voltage * DC current |
|
|
| `inverterdatachannelpdc2` | Number:Power | DC Power generated by MPPT tracker 2 |
|
|
| `inverterdatachannelpdc3` | Number:Power | DC Power generated by MPPT tracker 3 |
|
|
| `inverterdatachannelfac` | Number:Frequency | AC frequency |
|
|
| `inverterdatachanneliac` | Number:ElectricCurrent | AC current |
|
|
| `inverterdatachannelidc` | Number:ElectricCurrent | DC current |
|
|
| `inverterdatachannelidc2` | Number:ElectricCurrent | DC current of MPPT tracker 2 |
|
|
| `inverterdatachannelidc3` | Number:ElectricCurrent | DC current of MPPT tracker 3 |
|
|
| `inverterdatachanneluac` | Number:ElectricPotential | AC voltage |
|
|
| `inverterdatachanneludc` | Number:ElectricPotential | DC voltage |
|
|
| `inverterdatachanneludc2` | Number:ElectricPotential | DC voltage of MPPT tracker 2 |
|
|
| `inverterdatachanneludc3` | Number:ElectricPotential | DC voltage of MPPT tracker 3 |
|
|
| `inverterdatachanneldayenergy` | Number:Energy | Energy generated on current day |
|
|
| `inverterdatachannelyear` | Number:Energy | Energy generated in current year |
|
|
| `inverterdatachanneltotal` | Number:Energy | Energy generated overall |
|
|
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
|
|
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
|
| `powerflowchannelpgrid` | Number:Power | Grid Power (+ from grid, - to grid) |
|
|
| `powerflowchannelpload` | Number:Power | Load Power (+ generator, - consumer) |
|
|
| `powerflowchannelpakku` | Number:Power | Battery Power (+ discharge, - charge) |
|
|
| `powerflowchannelppv` | Number:Power | Solar Power (+ production) |
|
|
| `powerflowautonomy` | Number:Dimensionless | The current relative autonomy in % |
|
|
| `powerflowselfconsumption` | Number:Dimensionless | The current relative self consumption in % |
|
|
| `powerflowinverterpower` | Number:Power | Current power of the inverter, null if not running (+ produce/export, - consume/import) |
|
|
| `powerflowinvertersoc` | Number:Dimensionless | Current state of charge of the battery connected to the inverter in percent. |
|
|
| `powerflowinverter1power` | Number:Power | Current power of inverter 1, null if not running (+ produce/export, - consume/import) - DEPRECATED |
|
|
| `powerflowinverter1soc` | Number:Dimensionless | Current state of charge of inverter 1 in percent - DEPRECATED |
|
|
|
|
### `meter` Thing Channels
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
|
| `enable` | Number | 1 = enabled, 0 = disabled |
|
|
| `location` | Number | 0 = grid interconnection point (primary meter)<br/> 1 = load (primary meter) <br />3 = external generator (secondary meters)(multiple)<br />256-511 = subloads (secondary meters)(unique). Refer to Fronius Solar API. |
|
|
| `currentacphase1` | Number:ElectricCurrent | AC Current on Phase 1 |
|
|
| `currentacphase2` | Number:ElectricCurrent | AC Current on Phase 2 |
|
|
| `currentacphase3` | Number:ElectricCurrent | AC Current on Phase 3 |
|
|
| `voltageacphase1` | Number:ElectricPotential | AC Voltage on Phase 1 |
|
|
| `voltageacphase2` | Number:ElectricPotential | AC Voltage on Phase 2 |
|
|
| `voltageacphase3` | Number:ElectricPotential | AC Voltage on Phase 3 |
|
|
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
|
|
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
|
|
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
|
|
| `powerrealsum` | Number:Power | Real Power summed up |
|
|
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
|
|
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
|
|
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
|
|
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
|
| `energyrealsumproduced` | Number:Energy | Real Energy produced |
|
|
|
|
### `ohmpilot` Thing Channels
|
|
|
|
| Channel ID | Item Type | Description |
|
|
| ----------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
|
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
|
| `powerrealsum` | Number:Power | Real Power |
|
|
| `temperaturechannel1` | Number:Temperature | Temperature |
|
|
| `errorcode` | Number | Device error code |
|
|
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
|
|
|
|
## Properties
|
|
|
|
### `meter` Thing Properties
|
|
|
|
| Property | Description |
|
|
| -------------- | ------------------------------ |
|
|
| `modelId` | The model name of the meter |
|
|
| `serialNumber` | The serial number of the meter |
|
|
|
|
### `ohmpilot` Thing Properties
|
|
|
|
| Property | Description |
|
|
| -------------- | --------------------------------- |
|
|
| `modelId` | The model name of the ohmpilot |
|
|
| `serialNumber` | The serial number of the ohmpilot |
|
|
|
|
## Actions
|
|
|
|
:::warning
|
|
Battery control uses the battery management's time-dependent battery control settings of the inverter settings and therefore overrides user-specified time of use settings.
|
|
Please note that user-specified time of use plans cannot be used together with battery control, as battery control will override the user-specified time of use settings.
|
|
:::
|
|
|
|
The `powerinverter` Thing provides actions to control the battery charging and discharging behaviour of hybrid inverters, such as Symo Gen24 Plus, if username and password are provided in the bridge configuration.
|
|
|
|
You can retrieve the actions as follows:
|
|
|
|
:::: tabs
|
|
|
|
::: tab DSL
|
|
|
|
```java
|
|
val froniusInverterActions = getActions("fronius", "fronius:powerinverter:mybridge:myinverter")
|
|
```
|
|
|
|
:::
|
|
|
|
::: tab JS
|
|
|
|
```javascript
|
|
var froniusInverterActions = actions.thingActions('fronius', 'fronius:powerinverter:mybridge:myinverter');
|
|
```
|
|
|
|
:::
|
|
|
|
::::
|
|
|
|
Where the first parameter must always be `fronius` and the second must be the full Thing UID of the inverter.
|
|
|
|
### Available Actions
|
|
|
|
Once the actions instance has been retrieved, you can invoke the following methods:
|
|
|
|
- `resetBatteryControl()`: Remove all battery control schedules from the inverter.
|
|
- `holdBatteryCharge()`: Prevent the battery from discharging (removes all battery control schedules first and applies all the time).
|
|
- `addHoldBatteryChargeSchedule(LocalTime from, LocalTime until)`: Add a schedule to prevent the battery from discharging in the specified time range.
|
|
- `addHoldBatteryChargeSchedule(ZonedDateTime from, ZonedDateTime until)`: Add a schedule to prevent the battery from discharging in the specified time range.
|
|
- `forceBatteryCharging(QuantityType<Power> power)`: Force the battery to charge with the specified power (removes all battery control schedules first and applies all the time).
|
|
- `addForcedBatteryChargingSchedule(LocalTime from, LocalTime until, QuantityType<Power> power)`: Add a schedule to force the battery to charge with the specified power in the specified time range.
|
|
- `addForcedBatteryChargingSchedule(ZonedDateTime from, ZonedDateTime until, QuantityType<Power> power)`: Add a schedule to force the battery to charge with the specified power in the specified time range.
|
|
|
|
All methods return a boolean value indicating whether the action was successful.
|
|
|
|
### Examples
|
|
|
|
```javascript
|
|
var froniusInverterActions = actions.thingActions('fronius', 'fronius:powerinverter:mybridge:myinverter');
|
|
|
|
froniusInverterActions.resetBatteryControl();
|
|
froniusInverterActions.holdBatteryCharge();
|
|
froniusInverterActions.forceBatteryCharging(Quantity('5 kW'));
|
|
|
|
froniusInverterActions.resetBatteryControl();
|
|
froniusInverterActions.addHoldBatteryChargeSchedule(time.toZDT('18:00'), time.toZDT('22:00'));
|
|
froniusInverterActions.addForcedBatteryChargingSchedule(time.toZDT('22:00'), time.toZDT('23:59'), Quantity('5 kW'));
|
|
froniusInverterActions.addForcedBatteryChargingSchedule(time.toZDT('00:00'), time.toZDT('06:00'), Quantity('5 kW'));
|
|
```
|
|
|
|
## Full Example
|
|
|
|
demo.things:
|
|
|
|
```java
|
|
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
|
|
Thing powerinverter myinverter [deviceId=1]
|
|
Thing meter mymeter [deviceId=0]
|
|
Thing ohmpilot myohmpilot [deviceId=0]
|
|
}
|
|
```
|
|
|
|
demo.items:
|
|
|
|
```java
|
|
Number:Power AC_Power { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
|
|
Number:Energy Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
|
|
Number:Energy Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
|
|
Number:Energy Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
|
|
Number:Frequency FAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelfac" }
|
|
Number:ElectricCurrent IAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneliac" }
|
|
Number:ElectricCurrent IDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelidc" }
|
|
Number:ElectricPotential UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneluac" }
|
|
Number:ElectricPotential UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
|
|
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
|
|
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
|
|
Number:Power Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
|
|
Number:Power Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
|
|
Number:Power Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
|
|
Number:Power Production_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelppv" }
|
|
Number:Dimensionless Power_Autonomy { channel="fronius:powerinverter:mybridge:myinverter:powerflowautonomy" }
|
|
Number:Dimensionless Power_SelfConsumption { channel="fronius:powerinverter:mybridge:myinverter:powerflowselfconsumption" }
|
|
Number:Power Inverter1_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1power" }
|
|
Number:Dimensionless Inverter1_SOC { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1soc" }
|
|
|
|
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
|
|
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
|
|
Number:ElectricCurrent Meter_CurrentPhase1 { channel="fronius:meter:mybridge:mymeter:currentacphase1" }
|
|
Number:ElectricCurrent Meter_CurrentPhase2 { channel="fronius:meter:mybridge:mymeter:currentacphase2" }
|
|
Number:ElectricCurrent Meter_CurrentPhase3 { channel="fronius:meter:mybridge:mymeter:currentacphase3" }
|
|
Number:Voltage Meter_VoltagePhase1 { channel="fronius:meter:mybridge:mymeter:voltageacphase1" }
|
|
Number:Voltage Meter_VoltagePhase2 { channel="fronius:meter:mybridge:mymeter:voltageacphase2" }
|
|
Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:voltageacphase3" }
|
|
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
|
|
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
|
|
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
|
|
Number:Power Meter_PowerSum { channel="fronius:meter:mybridge:mymeter:powerrealsum" }
|
|
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
|
|
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
|
|
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
|
|
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
|
|
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
|
|
|
|
Number:Energy Ohmpilot_EnergyConsumed { channel="fronius:ohmpilot:mybridge:myohmpilot:energyrealsumconsumed" }
|
|
Number:Power Ohmpilot_PowerSum { channel="fronius:ohmpilot:mybridge:myohmpilot:powerrealsum" }
|
|
Number:Temperature Ohmpilot_Temperature { channel="fronius:ohmpilot:mybridge:myohmpilot:temperaturechannel1" }
|
|
Number Ohmpilot_State { channel="fronius:ohmpilot:mybridge:myohmpilot:statecode" }
|
|
Number Ohmpilot_Errorcode { channel="fronius:ohmpilot:mybridge:myohmpilot:errorcode" }
|
|
```
|
|
|
|
Note: Make sure to turn on the **Night Mode** in the Display Settings on the Fronius inverter to keep it from going offline at night.
|