[fronius] Improve logging in FroniusSymoInverterHandler (#19994)
* [fronius] Improve logging in FroniusSymoInverterHandler Signed-off-by: Florian Hotze <dev@florianhotze.com>
This commit is contained in:
+26
-16
@@ -99,6 +99,9 @@ public class FroniusSymoInverterHandler extends FroniusBaseThingHandler {
|
||||
private void initializeBatteryControl(String scheme, String hostname, @Nullable String username,
|
||||
@Nullable String password) {
|
||||
if (username == null || password == null) {
|
||||
logger.info(
|
||||
"Credentials are not configured in the bridge. Battery control is not available for Thing '{}'.",
|
||||
thing.getUID());
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -114,7 +117,8 @@ public class FroniusSymoInverterHandler extends FroniusBaseThingHandler {
|
||||
}
|
||||
}
|
||||
logger.warn(
|
||||
"The firmware version of the Fronius inverter could not be determined. Battery control is not available.");
|
||||
"The firmware version of the Fronius inverter could not be determined. Battery control is not available for Thing '{}'.",
|
||||
thing.getUID());
|
||||
}
|
||||
|
||||
private void updateProperties() {
|
||||
@@ -134,15 +138,17 @@ public class FroniusSymoInverterHandler extends FroniusBaseThingHandler {
|
||||
|
||||
@Override
|
||||
public void initialize() {
|
||||
config = getConfigAs(FroniusBaseDeviceConfiguration.class);
|
||||
FroniusBaseDeviceConfiguration config = this.config = getConfigAs(FroniusBaseDeviceConfiguration.class);
|
||||
Bridge bridge = getBridge();
|
||||
if (bridge != null) {
|
||||
FroniusBridgeConfiguration bridgeConfig = bridge.getConfiguration().as(FroniusBridgeConfiguration.class);
|
||||
inverterInfo = getInverterInfo(bridgeConfig.scheme, bridgeConfig.hostname, config.deviceId);
|
||||
updateProperties();
|
||||
initializeBatteryControl(bridgeConfig.scheme, bridgeConfig.hostname, bridgeConfig.username,
|
||||
bridgeConfig.password);
|
||||
if (bridge == null) {
|
||||
logger.warn("bridge is null in initialize(), this is a bug, please report it.");
|
||||
return;
|
||||
}
|
||||
FroniusBridgeConfiguration bridgeConfig = bridge.getConfiguration().as(FroniusBridgeConfiguration.class);
|
||||
inverterInfo = getInverterInfo(bridgeConfig.scheme, bridgeConfig.hostname, config.deviceId);
|
||||
updateProperties();
|
||||
initializeBatteryControl(bridgeConfig.scheme, bridgeConfig.hostname, bridgeConfig.username,
|
||||
bridgeConfig.password);
|
||||
super.initialize();
|
||||
}
|
||||
|
||||
@@ -156,18 +162,22 @@ public class FroniusSymoInverterHandler extends FroniusBaseThingHandler {
|
||||
super.handleBridgeConfigurationUpdate(configurationParameters);
|
||||
Bridge bridge = getBridge();
|
||||
FroniusBaseDeviceConfiguration config = this.config;
|
||||
if (bridge != null && config != null) {
|
||||
FroniusBridgeConfiguration bridgeConfig = bridge.getConfiguration().as(FroniusBridgeConfiguration.class);
|
||||
inverterInfo = getInverterInfo(bridgeConfig.scheme, bridgeConfig.hostname, config.deviceId);
|
||||
updateProperties();
|
||||
initializeBatteryControl(bridgeConfig.scheme, bridgeConfig.hostname, bridgeConfig.username,
|
||||
bridgeConfig.password);
|
||||
if (bridge == null || config == null) {
|
||||
logger.warn(
|
||||
"bridge or config is null in handleBridgeConfigurationUpdate(), this is a bug, please report it.");
|
||||
return;
|
||||
}
|
||||
FroniusBridgeConfiguration bridgeConfig = bridge.getConfiguration().as(FroniusBridgeConfiguration.class);
|
||||
inverterInfo = getInverterInfo(bridgeConfig.scheme, bridgeConfig.hostname, config.deviceId);
|
||||
updateProperties();
|
||||
initializeBatteryControl(bridgeConfig.scheme, bridgeConfig.hostname, bridgeConfig.username,
|
||||
bridgeConfig.password);
|
||||
}
|
||||
|
||||
public @Nullable FroniusBatteryControl getBatteryControl() {
|
||||
if (batteryControl == null) {
|
||||
logger.warn("Battery control is not available. Check the bridge configuration.");
|
||||
logger.warn("Battery control is not available for Thing '{}'. Check the bridge configuration.",
|
||||
thing.getUID());
|
||||
}
|
||||
return batteryControl;
|
||||
}
|
||||
@@ -342,7 +352,7 @@ public class FroniusSymoInverterHandler extends FroniusBaseThingHandler {
|
||||
* @param unit The default unit to use when value is null
|
||||
* @return a QuantityType from the given value
|
||||
*/
|
||||
private QuantityType<?> getQuantityOrZero(@Nullable ValueUnit value, Unit unit) {
|
||||
private QuantityType<?> getQuantityOrZero(@Nullable ValueUnit value, Unit<?> unit) {
|
||||
QuantityType<?> val = null;
|
||||
if (value != null) {
|
||||
val = value.asQuantityType().toUnit(unit);
|
||||
|
||||
Reference in New Issue