[modbus.studer] Some little markdown and grammar corrections (#16324)

* modbus.studer: Some little markdown and grammar corrections

Signed-off-by: Thomas Karl Pietrowski <thopiekar@gmail.com>

Co-authored-by: lsiepel <leosiepel@gmail.com>
Signed-off-by: Thomas Karl Pietrowski <thopiekar@gmail.com>
Signed-off-by: Ciprian Pascu <contact@ciprianpascu.ro>
This commit is contained in:
Thomas Karl Pietrowski 2024-02-01 08:12:13 +01:00 committed by Ciprian Pascu
parent 5148f78829
commit 1f63d0f21a

View File

@ -2,7 +2,7 @@
This extension adds support for the Studer protocol. This extension adds support for the Studer protocol.
Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland Studer Innotec, founded in 1987 by Roland Studer, is an ISO-certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland.
For a list of certified products see this page: <https://www.studer-innotec.com/> For a list of certified products see this page: <https://www.studer-innotec.com/>
@ -13,7 +13,7 @@ Note, that the things will show up under the Modbus binding.
| Thing Type IDs | Description | Picture | | Thing Type IDs | Description | Picture |
|----------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------| |----------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------|
| bsp | For BSP that offer a highly precise measuring for Xtender, VarioTrack and VarioString systems | ![BSP](doc/bsp.png) | | bsp | For BSP that offers a highly precise measuring for Xtender, VarioTrack and VarioString systems | ![BSP](doc/bsp.png) |
| xtender | For the Xtender models for system capacities from 0.5kVA to 72kVA that allow for the optimal use of available energy | ![Xtender](doc/xtender.png) | | xtender | For the Xtender models for system capacities from 0.5kVA to 72kVA that allow for the optimal use of available energy | ![Xtender](doc/xtender.png) |
| variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp | ![VarioTrack](doc/variotrack.png) | | variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp | ![VarioTrack](doc/variotrack.png) |
| variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 | ![VarioString](doc/variostring.png) | | variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 | ![VarioString](doc/variostring.png) |
@ -29,7 +29,6 @@ Please refer to your device's vendor documentation how model blocks are laid for
OR: If there is no offset configured (default config) on the dip switch in RS-485, the following are mostly interesting for getting things up and running: OR: If there is no offset configured (default config) on the dip switch in RS-485, the following are mostly interesting for getting things up and running:
|--------|-----------------------|
| Offset | Device | | Offset | Device |
|--------|-----------------------| |--------|-----------------------|
| 10 | Multicast Xtender | | 10 | Multicast Xtender |
@ -39,11 +38,10 @@ OR: If there is no offset configured (default config) on the dip switch in RS-48
| 40 | Multicast Variostring | | 40 | Multicast Variostring |
| 41-55 | Variostring 1-15 | | 41-55 | Variostring 1-15 |
| 61 | BSP/Xcom-CAN | | 61 | BSP/Xcom-CAN |
|--------|-----------------------|
More Details about that can be found in the technical specification and appendix for Studer RTU Modbus protocol. Check default config (dip switches 1 and 2 off) while configuring the pin-out on the RS-485! More Details about that can be found in the technical specification and appendix for Studer RTU Modbus protocol. Check the default config (dip switches 1 and 2 off) while configuring the pin-out on the RS-485!
Multicast writes on any devices of given class, but reads only on the first available device (Not Summary!). As currently there are no writes available, 10/20/40 is useless for now. Multicast writes on any devices of given class, but reads only on the first available device (Not Summary!). Currently, there are no writes available, 10/20/40 is useless for now.
The following parameters are valid for all thing types: The following parameters are valid for all thing types:
@ -54,7 +52,7 @@ The following parameters are valid for all thing types:
## Channels ## Channels
The following Channels, and their associated channel types are shown below divided by device. The following channels and their associated channel types are shown below divided by device.
### BSP ### BSP
@ -70,7 +68,7 @@ All channels read for a BSP device
### Xtender ### Xtender
All channels read for a Xtender device All channels read for an Xtender device
| Channel | Type | Description | | Channel | Type | Description |
| ----------------- | ------------------------ | ----------------------- | | ----------------- | ------------------------ | ----------------------- |