diff --git a/bundles/org.openhab.binding.modbus.studer/README.md b/bundles/org.openhab.binding.modbus.studer/README.md index 39b53ae2e36..d3358efd626 100644 --- a/bundles/org.openhab.binding.modbus.studer/README.md +++ b/bundles/org.openhab.binding.modbus.studer/README.md @@ -2,7 +2,7 @@ This extension adds support for the Studer protocol. -Studer Innotec, founded in 1987 by Roland Studer, is an ISO certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland +Studer Innotec, founded in 1987 by Roland Studer, is an ISO-certified company that develops and manufactures inverters, inverter/chargers and MPPT solar charge controllers to communicate over the Modbus protocol entirely in Switzerland. For a list of certified products see this page: @@ -13,7 +13,7 @@ Note, that the things will show up under the Modbus binding. | Thing Type IDs | Description | Picture | |----------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------| -| bsp | For BSP that offer a highly precise measuring for Xtender, VarioTrack and VarioString systems | ![BSP](doc/bsp.png) | +| bsp | For BSP that offers a highly precise measuring for Xtender, VarioTrack and VarioString systems | ![BSP](doc/bsp.png) | | xtender | For the Xtender models for system capacities from 0.5kVA to 72kVA that allow for the optimal use of available energy | ![Xtender](doc/xtender.png) | | variotrack | For the VarioTrack models of MPPT solar charge controllers for systems with solar PV capacity from 1 - 75kWp | ![VarioTrack](doc/variotrack.png) | | variostring | For the VarioString models of MPPT solar charge controllers for systems with solar PV capacity from 4 | ![VarioString](doc/variostring.png) | @@ -29,7 +29,6 @@ Please refer to your device's vendor documentation how model blocks are laid for OR: If there is no offset configured (default config) on the dip switch in RS-485, the following are mostly interesting for getting things up and running: -|--------|-----------------------| | Offset | Device | |--------|-----------------------| | 10 | Multicast Xtender | @@ -39,11 +38,10 @@ OR: If there is no offset configured (default config) on the dip switch in RS-48 | 40 | Multicast Variostring | | 41-55 | Variostring 1-15 | | 61 | BSP/Xcom-CAN | -|--------|-----------------------| -More Details about that can be found in the technical specification and appendix for Studer RTU Modbus protocol. Check default config (dip switches 1 and 2 off) while configuring the pin-out on the RS-485! +More Details about that can be found in the technical specification and appendix for Studer RTU Modbus protocol. Check the default config (dip switches 1 and 2 off) while configuring the pin-out on the RS-485! -Multicast writes on any devices of given class, but reads only on the first available device (Not Summary!). As currently there are no writes available, 10/20/40 is useless for now. +Multicast writes on any devices of given class, but reads only on the first available device (Not Summary!). Currently, there are no writes available, 10/20/40 is useless for now. The following parameters are valid for all thing types: @@ -54,7 +52,7 @@ The following parameters are valid for all thing types: ## Channels -The following Channels, and their associated channel types are shown below divided by device. +The following channels and their associated channel types are shown below divided by device. ### BSP @@ -70,7 +68,7 @@ All channels read for a BSP device ### Xtender -All channels read for a Xtender device +All channels read for an Xtender device | Channel | Type | Description | | ----------------- | ------------------------ | ----------------------- |