Keba Binding
This binding integrates the Keba KeContact EV Charging Stations.
Supported Things
The Keba KeContact P20 and P30 stations are supported by this binding, the thing type id is kecontact
.
Thing Configuration
The Keba KeContact P20/30 requires the ip address as the configuration parameter ipAddress
. Optionally, a refresh interval (in seconds) can be defined as parameter refreshInterval
that defines the polling of values from the charging station.
Channels
All devices support the following channels:
Channel ID | Item Type | Read-only | Description |
---|---|---|---|
state | Number | yes | current operational state of the wallbox |
enabled | Switch | no | activation state of the wallbox |
maxpresetcurrent | Number | no | maximum current the charging station should deliver to the EV |
power | Number | yes | active power delivered by the charging station |
wallbox | Switch | yes | plug state of wallbox |
vehicle | Switch | yes | plug state of vehicle |
locked | Switch | yes | lock state of plug at vehicle |
I1/2/3 | Number | yes | current for the given phase |
U1/2/3 | Number | yes | voltage for the given phase |
output | Switch | no | state of the X1 relais |
input | Switch | yes | state of the X2 contact |
display | String | yes | display text on wallbox |
error1 | String | yes | error code state 1, if in error (see the KeContact FAQ) |
error2 | String | yes | error code state 2, if in error (see the KeContact FAQ) |
maxsystemcurrent | Number | yes | maximum current the wallbox can deliver |
failsafecurrent | Number | yes | maximum current the wallbox can deliver, if network is lost |
uptime | DateTime | yes | system uptime since the last reset of the wallbox |
sessionconsumption | Number | yes | energy delivered in current session |
totalconsumption | Number | yes | total energy delivered since the last reset of the wallbox |
authreq | Switch | yes | authentication required |
authon | Switch | yes | authentication enabled |
sessionrfidtag | String | yes | RFID tag used for the last charging session |
sessionrfidclass | String | yes | RFID tag class used for the last charging session |
sessionid | Number | yes | session ID of the last charging session |
setenergylimit | Number | no | set an energy limit for an already running or the next charging session |
authenticate | String | no | authenticate and start a session using RFID tag+RFID class |
Example
demo.Things:
Thing keba:kecontact:1 [ipAddress="192.168.0.64", refreshInterval=30]
demo.items:
Dimmer KebaCurrentRange {channel="keba:kecontact:1:maxpresetcurrentrange"}
Number KebaCurrent {channel="keba:kecontact:1:maxpresetcurrent"}
Number KebaSystemCurrent {channel="keba:kecontact:1:maxsystemcurrent"}
Number KebaFailSafeCurrent {channel="keba:kecontact:1:failsafecurrent"}
String KebaState {channel="keba:kecontact:1:state"}
Switch KebaSwitch {channel="keba:kecontact:1:enabled"}
Switch KebaWallboxPlugged {channel="keba:kecontact:1:wallbox"}
Switch KebaVehiclePlugged {channel="keba:kecontact:1:vehicle"}
Switch KebaPlugLocked {channel="keba:kecontact:1:locked"}
DateTime KebaUptime "Uptime [%1$tY Y, %1$tm M, %1$td D, %1$tT]" {channel="keba:kecontact:1:uptime"}
Number KebaI1 {channel="keba:kecontact:1:I1"}
Number KebaI2 {channel="keba:kecontact:1:I2"}
Number KebaI3 {channel="keba:kecontact:1:I3"}
Number KebaU1 {channel="keba:kecontact:1:U1"}
Number KebaU2 {channel="keba:kecontact:1:U2"}
Number KebaU3 {channel="keba:kecontact:1:U3"}
Number KebaPower {channel="keba:kecontact:1:power"}
Number KebaSessionEnergy {channel="keba:kecontact:1:sessionconsumption"}
Number KebaTotalEnergy {channel="keba:kecontact:1:totalconsumption"}
Switch KebaInputSwitch {channel="keba:kecontact:1:input"}
Switch KebaOutputSwitch {channel="keba:kecontact:1:output"}
Number KebaSetEnergyLimit {channel="keba:kecontact:1:setenergylimit"}
demo.sitemap:
sitemap demo label="Main Menu"
{
Text label="Charging Station" {
Text item=KebaState label="Operating State [%s]"
Text item=KebaUptime
Switch item=KebaSwitch label="Enabled" mappings=[ON=ON, OFF=OFF ]
Switch item=KebaWallboxPlugged label="Plugged into wallbox" mappings=[ON=ON, OFF=OFF ]
Switch item=KebaVehiclePlugged label="Plugged into vehicle" mappings=[ON=ON, OFF=OFF ]
Switch item=KebaPlugLocked label="Plug locked" mappings=[ON=ON, OFF=OFF ]
Slider item=KebaCurrentRange switchSupport label="Maximum supply current [%.1f %%]"
Text item=KebaCurrent label="Maximum supply current [%.0f mA]"
Text item=KebaSystemCurrent label="Maximum system supply current [%.0f mA]"
Text item=KebaFailSafeCurrent label="Failsafe supply current [%.0f mA]"
Text item=KebaSessionEnergy label="Energy during current session [%.0f Wh]"
Text item=KebaTotalEnergy label="Energy during all sessions [%.0f Wh]"
Switch item=KebaSetEnergyLimit label="Set charge energy limit" mappings=[0="off", 20000="20kWh"]
}
}