OpenTherm Gateway Binding
This binding is used to integrate the OpenTherm Gateway into openHAB. The OpenTherm Gateway is a module designed by Schelte Bron that is connected in between a boiler and a thermostat and communicates using the OpenTherm protocol.
More information on the OpenTherm Gateway device can be found at http://otgw.tclcode.com/
Supported Things
The OpenTherm Gateway binding currently only supports one thing, and that's the gateway itself.
Discovery
The binding does not support auto discovery.
Binding Configuration
The binding itself does not require any configuration.
Thing Configuration
The binding is designed to support various ways of connecting to the OpenTherm Gateway device, but currently only supports a TCP socket connection. The configuration settings for the thing are Hostname/IP address and Port, which are used to connect to the gateway, and an automatic connection retry interval in case the connection to the OpenTherm Gateway device is lost.
Parameter | Name | Description | Required | Default |
---|---|---|---|---|
ipaddress |
Hostname or IP address | The hostname or IP address to connect to the OpenTherm Gateway. | yes | |
port |
Port | The port used to connect to the OpenTherm Gateway. | yes | |
connectionRetryInterval |
Connection Retry Interval | The interval in seconds to retry connecting (0 = disabled). | yes | 60 |
Channels
The OpenTherm Gateway binding supports the following channels:
Channel Type ID | Item Type | Description | Read Only |
---|---|---|---|
roomtemp | Number | Current sensed room temperature | yes |
roomsetpoint | Number | Current room temperature setpoint | yes |
temperaturetemporary | Number | Temporary override room temperature setpoint | no |
temperatureconstant | Number | Constant override room temperature setpoint | no |
controlsetpoint | Number | Central heating water setpoint | yes |
dhwtemp | Number | Domestic hot water temperature | yes |
tdhwset | Number | Domestic hot water temperature setpoint | yes |
overridedhwsetpoint | Number | Domestic hot water temperature setpoint override | no |
flowtemp | Number | Boiler water temperature | yes |
returntemp | Number | Return water temperature | yes |
outsidetemp | Number | Outside temperature | no |
waterpressure | Number | Central heating water pressure | yes |
ch_enable | Switch | Central heating enabled | yes |
ch_mode | Switch | Central heating active | yes |
dhw_enable | Switch | Domestic hot water enabled | yes |
dhw_mode | Switch | Domestic hot water active | yes |
flame | Switch | Burner active | yes |
modulevel | Number | Relative modulation level | yes |
maxrelmdulevel | Number | Maximum relative modulation level | yes |
fault | Switch | Fault indication | yes |
servicerequest | Switch | Service required | yes |
lockout-reset | Switch | Lockout-reset enabled | yes |
lowwaterpress | Switch | Low water pressure fault | yes |
gasflamefault | Switch | Gas or flame fault | yes |
airpressfault | Switch | Air pressure fault | yes |
waterovtemp | Switch | Water over-temperature fault | yes |
oemfaultcode | Switch | OEM fault code | yes |
sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | no |
Full Example
demo.things
Thing openthermgateway:otgw:1 [ ipaddress="192.168.1.100", port=8000, connectionRetryInterval=60 ]
demo.items
Number RoomTemperature "Room temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:roomtemp" }
Number RoomSetpoint "Room setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:roomsetpoint" }
Number TemporaryRoomSetpointOverride "Temporary room setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:temperaturetemporary" }
Number ConstantRoomSetpointOverride "Constant room setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:temperatureconstant" }
Number ControlSetpoint "Control setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint" }
Number DomesticHotWaterTemperature "Domestic hot water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:dhwtemp" }
Number DomesticHotWaterSetpoint "Domestic hot water setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:tdhwset" }
Number DomesticHotWaterSetpointOverride "Domestic hot water setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:overridedhwsetpoint" }
Number BoilerWaterTemperature "Boiler water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:flowtemp" }
Number ReturnWaterTemperature "Return water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:returntemp" }
Number OutsideTemperature "Outside temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:outsidetemp" }
Number CentralHeatingWaterPressure "Central heating water pressure [%.1f bar]" { channel="openthermgateway:otgw:1:waterpressure" }
Switch CentralHeatingEnabled "Central heating enabled" <switch> { channel="openthermgateway:otgw:1:ch_enable" }
Switch CentralHeatingActive "Central heating active" <switch> { channel="openthermgateway:otgw:1:ch_mode" }
Switch DomesticHotWaterEnabled "Domestic hot water enabled" <switch> { channel="openthermgateway:otgw:1:dhw_enable" }
Switch DomesticHotWaterActive "Domestic hot water active" <switch> { channel="openthermgateway:otgw:1:dhw_mode" }
Switch BurnerActive "Burner active" <switch> { channel="openthermgateway:otgw:1:flame" }
Number RelativeModulationLevel "Relative modulation level [%.1f %%]" { channel="openthermgateway:otgw:1:modulevel" }
Number MaximumRelativeModulationLevel "Maximum relative modulation level [%.1f %%]" { channel="openthermgateway:otgw:1:maxrelmdulevel" }
Switch Fault "Fault indication" <switch> { channel="openthermgateway:otgw:1:fault" }
Switch ServiceRequest "Service required" <switch> { channel="openthermgateway:otgw:1:servicerequest" }
Switch LockoutReset "Lockout-reset" <switch> { channel="openthermgateway:otgw:1:lockout-reset" }
Switch LowWaterPress "Low water pressure fault" <switch> { channel="openthermgateway:otgw:1:lowwaterpress" }
Switch GasFlameFault "Gas or flame fault" <switch> { channel="openthermgateway:otgw:1:gasflamefault" }
Switch AirPressFault "Air pressure fault" <switch> { channel="openthermgateway:otgw:1:airpressfault" }
Switch WaterOvTemp "Water over-temperature fault" <switch> { channel="openthermgateway:otgw:1:waterovtemp" }
Number OemFaultCode "OEM fault code" { channel="openthermgateway:otgw:1:oemfaultcode" }
Text SendCommand "Send command channel" { channel="openthermgateway:otgw:1:sendcommand" }
demo.sitemap
sitemap demo label="Main Menu" {
Frame label="OpenTherm Gateway" {
Text item="RoomTemperature" icon="temperature" label="Room temperature [%.1f °C]"
Text item="RoomSetpoint" icon="temperature" label="Room setpoint [%.1f °C]"
Setpoint item="TemporaryRoomSetpointOverride" icon="temperature" label="Temporary room setpoint override [%.1f °C]" minValue="0" maxValue="30" step="0.1"
Setpoint item="ConstantRoomSetpointOverride" icon="temperature" label="Constant room setpoint override [%.1f °C]" minValue="0" maxValue="30" step="0.1"
Text item="ControlSetpoint" icon="temperature" label="Control setpoint [%.1f °C]"
Text item="DomesticHotWaterTemperature" icon="temperature" label="Domestic hot water temperature [%.1f °C]"
Text item="DomesticHotWaterSetpoint" icon="temperature" label="Domestic hot water setpoint [%.1f °C]"
Setpoint item="DomesticHotWaterSetpointOverride" icon="temperature" label="Domestic hot water setpoint override [%.1f °C]" minValue="0" maxValue="100" step="0.1"
Text item="BoilerWaterTemperature" icon="temperature" label="Boiler water temperature [%.1f °C]"
Text item="ReturnWaterTemperature" icon="temperature" label="Return water temperature [%.1f °C]"
Setpoint item="OutsideTemperature" icon="temperature" label="Outside temperature [%.1f °C]" minValue="-40" maxValue="100" step="0.1"
Text item="CentralHeatingWaterPressure" icon="" label="Central heating water pressure [%.1f bar]"
Switch item="CentralHeatingEnabled" icon="switch" label="Central heating enabled"
Switch item="CentralHeatingActive" icon="switch" label="Central heating active"
Switch item="DomesticHotWaterEnabled" icon="switch" label="Domestic hot water enabled"
Switch item="DomesticHotWaterActive" icon="switch" label="Domestic hot water active"
Switch item="BurnerActive" icon="switch" label="Burner active"
Text item="RelativeModulationLevel" icon="" label="Relative modulation level [%.1f %%]"
Text item="MaximumRelativeModulationLevel" icon="" label="Maximum relative modulation level [%.1f %%]"
Switch item="Fault" icon="" label="Fault indication"
Switch item="ServiceRequest" icon="" label="Service required"
Switch item="LockoutReset" icon="" label="Lockout-reset"
Switch item="LowWaterPress" icon="" label="Low water pressure fault"
Switch item="GasFlameFault" icon="" label="Gas or flame fault"
Switch item="AirPressFault" icon="" label="Air pressure fault"
Switch item="waterOvTemp" icon="" label="Water over-temperature fault"
Text item="OemFaultCode" icon="" label="OEM fault code"
}
}