mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-10 15:11:59 +01:00
.. | ||
src/main | ||
NOTICE | ||
pom.xml | ||
README.md |
Fronius Binding
This binding uses the Fronius Solar API V1 to obtain data from Fronius devices.
It supports Fronius inverters and Fronius Smart Meter. Supports:
- Fronius Symo
- Fronius Symo Gen24
- Fronius Smart Meter 63A
- Fronius Smart Meter TS 65A-3
- Fronius Ohmpilot
Supported Things
Thing Type | Description |
---|---|
bridge |
The Bridge |
powerinverter |
Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
meter |
Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0) |
ohmpilot |
Fronius Ohmpilot. (The default id = 0) |
Discovery
There is no discovery implemented. You have to create your Things manually and specify the hostname or IP address of the Datalogger and the device id.
Binding Configuration
The binding has no configuration options, all configuration is done at bridge
, powerinverter
, meter
or ohmpilot
level.
Thing Configuration
Bridge Thing Configuration
Parameter | Description |
---|---|
hostname |
The hostname or IP address of your Fronius Datalogger |
refreshInterval |
Refresh interval in seconds |
Powerinverter Thing Configuration
Parameter | Description |
---|---|
deviceId |
The identifier of your device (Default: 1) |
Meter Thing Configuration
Parameter | Description |
---|---|
deviceId |
The identifier of your smart meter (Default: 0) |
Ohmpilot Thing Configuration
Parameter | Description |
---|---|
deviceId |
The identifier of your ohmpilot (Default: 0) |
Channels
Channels for powerinverter
Thing
Channel ID | Item Type | Description |
---|---|---|
inverterdatachannelpac |
Number:Power | AC Power generated |
inverterdatachannelpdc |
Number:Power | DC Power calculated from DC voltage * DC current |
inverterdatachannelpdc2 |
Number:Power | DC Power generated by MPPT tracker 2 |
inverterdatachannelpdc3 |
Number:Power | DC Power generated by MPPT tracker 3 |
inverterdatachannelfac |
Number:Frequency | AC frequency |
inverterdatachanneliac |
Number:ElectricCurrent | AC current |
inverterdatachannelidc |
Number:ElectricCurrent | DC current |
inverterdatachannelidc2 |
Number:ElectricCurrent | DC current of MPPT tracker 2 |
inverterdatachannelidc3 |
Number:ElectricCurrent | DC current of MPPT tracker 3 |
inverterdatachanneluac |
Number:ElectricPotential | AC voltage |
inverterdatachanneludc |
Number:ElectricPotential | DC voltage |
inverterdatachanneludc2 |
Number:ElectricPotential | DC voltage of MPPT tracker 2 |
inverterdatachanneludc3 |
Number:ElectricPotential | DC voltage of MPPT tracker 3 |
inverterdatachanneldayenergy |
Number:Energy | Energy generated on current day |
inverterdatachannelyear |
Number:Energy | Energy generated in current year |
inverterdatachanneltotal |
Number:Energy | Energy generated overall |
inverterdatadevicestatuserrorcode |
Number | Device error code |
inverterdatadevicestatusstatuscode |
Number | Device status code0 - 6 Startup7 Running 8 Standby9 Bootloading10 Error |
powerflowchannelpgrid |
Number:Power | Grid Power (+ from grid, - to grid) |
powerflowchannelpload |
Number:Power | Load Power (+ generator, - consumer) |
powerflowchannelpakku |
Number:Power | Battery Power (+ discharge, - charge) |
powerflowchannelppv |
Number:Power | Solar Power (+ production) |
powerflowautonomy |
Number:Dimensionless | The current relative autonomy in % |
powerflowselfconsumption |
Number:Dimensionless | The current relative self consumption in % |
powerflowinverterpower |
Number:Power | Current power of the inverter, null if not running (+ produce/export, - consume/import) |
powerflowinvertersoc |
Number:Dimensionless | Current state of charge of the battery connected to the inverter in percent. |
powerflowinverter1power |
Number:Power | Current power of inverter 1, null if not running (+ produce/export, - consume/import) - DEPRECATED |
powerflowinverter1soc |
Number:Dimensionless | Current state of charge of inverter 1 in percent - DEPRECATED |
Channels for meter
Thing
Channel ID | Item Type | Description |
---|---|---|
enable |
Number | 1 = enabled, 0 = disabled |
location |
Number | 0 = grid interconnection point (primary meter) 1 = load (primary meter) 3 = external generator (secondary meters)(multiple) 256-511 = subloads (secondary meters)(unique). Refer to Fronius Solar API. |
currentacphase1 |
Number:ElectricCurrent | AC Current on Phase 1 |
currentacphase2 |
Number:ElectricCurrent | AC Current on Phase 2 |
currentacphase3 |
Number:ElectricCurrent | AC Current on Phase 3 |
voltageacphase1 |
Number:ElectricPotential | AC Voltage on Phase 1 |
voltageacphase2 |
Number:ElectricPotential | AC Voltage on Phase 2 |
voltageacphase3 |
Number:ElectricPotential | AC Voltage on Phase 3 |
powerrealphase1 |
Number:Power | Real Power on Phase 1 |
powerrealphase2 |
Number:Power | Real Power on Phase 2 |
powerrealphase3 |
Number:Power | Real Power on Phase 3 |
powerrealsum |
Number:Power | Real Power summed up |
powerfactorphase1 |
Number | Power Factor on Phase 1 |
powerfactorphase2 |
Number | Power Factor on Phase 2 |
powerfactorphase3 |
Number | Power Factor on Phase 3 |
energyrealsumconsumed |
Number:Energy | Real Energy consumed |
energyrealsumproduced |
Number:Energy | Real Energy produced |
Channels for ohmpilot
Thing
Channel ID | Item Type | Description |
---|---|---|
energyrealsumconsumed |
Number:Energy | Real Energy consumed |
powerrealsum |
Number:Power | Real Power |
temperaturechannel1 |
Number:Temperature | Temperature |
errorcode |
Number | Device error code |
statecode |
Number | Device state code0 up and running 1 keep minimum temperature 2 legionella protection 3 critical fault4 fault5 boost mode |
Properties
The meter
Thing has the following properties:
Property | Description |
---|---|
modelId |
The model name of the meter |
serialNumber |
The serial number of the meter |
The ohmpilot
Thing has the following properties:
Property | Description |
---|---|
modelId |
The model name of the ohmpilot |
serialNumber |
The serial number of the ohmpilot |
Full Example
demo.things:
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
Thing powerinverter myinverter [deviceId=1]
Thing meter mymeter [deviceId=0]
Thing ohmpilot myohmpilot [deviceId=0]
}
demo.items:
Number:Power AC_Power { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
Number:Energy Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
Number:Energy Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
Number:Energy Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
Number:Frequency FAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelfac" }
Number:ElectricCurrent IAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneliac" }
Number:ElectricCurrent IDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelidc" }
Number:ElectricPotential UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneluac" }
Number:ElectricPotential UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
Number:Power Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
Number:Power Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
Number:Power Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
Number:Power Production_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelppv" }
Number:Dimensionless Power_Autonomy { channel="fronius:powerinverter:mybridge:myinverter:powerflowautonomy" }
Number:Dimensionless Power_SelfConsumption { channel="fronius:powerinverter:mybridge:myinverter:powerflowselfconsumption" }
Number:Power Inverter1_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1power" }
Number:Dimensionless Inverter1_SOC { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1soc" }
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
Number:ElectricCurrent Meter_CurrentPhase1 { channel="fronius:meter:mybridge:mymeter:currentacphase1" }
Number:ElectricCurrent Meter_CurrentPhase2 { channel="fronius:meter:mybridge:mymeter:currentacphase2" }
Number:ElectricCurrent Meter_CurrentPhase3 { channel="fronius:meter:mybridge:mymeter:currentacphase3" }
Number:Voltage Meter_VoltagePhase1 { channel="fronius:meter:mybridge:mymeter:voltageacphase1" }
Number:Voltage Meter_VoltagePhase2 { channel="fronius:meter:mybridge:mymeter:voltageacphase2" }
Number:Voltage Meter_VoltagePhase3 { channel="fronius:meter:mybridge:mymeter:voltageacphase3" }
Number:Power Meter_PowerPhase1 { channel="fronius:meter:mybridge:mymeter:powerrealphase1" }
Number:Power Meter_PowerPhase2 { channel="fronius:meter:mybridge:mymeter:powerrealphase2" }
Number:Power Meter_PowerPhase3 { channel="fronius:meter:mybridge:mymeter:powerrealphase3" }
Number:Power Meter_PowerSum { channel="fronius:meter:mybridge:mymeter:powerrealsum" }
Number Meter_PowerFactorPhase1 { channel="fronius:meter:mybridge:mymeter:powerfactorphase1" }
Number Meter_PowerFactorPhase2 { channel="fronius:meter:mybridge:mymeter:powerfactorphase2" }
Number Meter_PowerFactorPhase3 { channel="fronius:meter:mybridge:mymeter:powerfactorphase3" }
Number:Energy Meter_EnergyConsumed { channel="fronius:meter:mybridge:mymeter:energyrealsumconsumed" }
Number:Energy Meter_EnergyProduced { channel="fronius:meter:mybridge:mymeter:energyrealsumproduced" }
Number:Energy Ohmpilot_EnergyConsumed { channel="fronius:ohmpilot:mybridge:myohmpilot:energyrealsumconsumed" }
Number:Power Ohmpilot_PowerSum { channel="fronius:ohmpilot:mybridge:myohmpilot:powerrealsum" }
Number:Temperature Ohmpilot_Temperature { channel="fronius:ohmpilot:mybridge:myohmpilot:temperaturechannel1" }
Number Ohmpilot_State { channel="fronius:ohmpilot:mybridge:myohmpilot:statecode" }
Number Ohmpilot_Errorcode { channel="fronius:ohmpilot:mybridge:myohmpilot:errorcode" }
Note: Make sure to turn on the Night Mode in the Display Settings on the Fronius inverter to keep it from going offline at night.