[openthermgateway] Added support for firmware version 5.0 (#10040)
* Added commands for second central heating circuit * Added command for temperature sensor * Added controlsetpoint2 and ch2_enable channels Signed-off-by: Arjen Korevaar <a.korevaar@mephix.com>
This commit is contained in:
parent
9498590edb
commit
f4c2769552
@ -32,41 +32,47 @@ The configuration settings for the thing are Hostname/IP address and Port, which
|
||||
|
||||
The OpenTherm Gateway binding supports the following channels:
|
||||
|
||||
| Channel Type ID | Item Type | Description | Read Only |
|
||||
|--------------------------|----------------------|----------------------------------------------------------|-----------|
|
||||
| roomtemp | Number:Temperature | Current sensed room temperature | yes |
|
||||
| roomsetpoint | Number:Temperature | Current room temperature setpoint | yes |
|
||||
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | no |
|
||||
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | no |
|
||||
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | yes |
|
||||
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by thermostat | yes |
|
||||
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured at gateway | no |
|
||||
| dhwtemp | Number:Temperature | Domestic hot water temperature | yes |
|
||||
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | yes |
|
||||
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | no |
|
||||
| flowtemp | Number:Temperature | Boiler water temperature | yes |
|
||||
| returntemp | Number:Temperature | Return water temperature | yes |
|
||||
| outsidetemp | Number:Temperature | Outside temperature | no |
|
||||
| waterpressure | Number:Pressure | Central heating water pressure | yes |
|
||||
| ch_enable | Switch | Central heating enabled set at boiler | yes |
|
||||
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | yes |
|
||||
| ch_enableoverride | Switch | Central heating enabled overridden at gateway | yes |
|
||||
| ch_mode | Switch | Central heating active | yes |
|
||||
| dhw_enable | Switch | Domestic hot water enabled | yes |
|
||||
| dhw_mode | Switch | Domestic hot water active | yes |
|
||||
| flame | Switch | Burner active | yes |
|
||||
| modulevel | Number:Dimensionless | Relative modulation level | yes |
|
||||
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | yes |
|
||||
| fault | Switch | Fault indication | yes |
|
||||
| servicerequest | Switch | Service required | yes |
|
||||
| lockout-reset | Switch | Lockout-reset enabled | yes |
|
||||
| lowwaterpress | Switch | Low water pressure fault | yes |
|
||||
| gasflamefault | Switch | Gas or flame fault | yes |
|
||||
| airpressfault | Switch | Air pressure fault | yes |
|
||||
| waterovtemp | Switch | Water over-temperature fault | yes |
|
||||
| oemfaultcode | Switch | OEM fault code | yes |
|
||||
| diag | Switch | Diagnostics indication | yes |
|
||||
| sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | no |
|
||||
| Channel Type ID | Item Type | Description | Access |
|
||||
|---------------------------|----------------------|----------------------------------------------------------|--------|
|
||||
| roomtemp | Number:Temperature | Current sensed room temperature | R |
|
||||
| roomsetpoint | Number:Temperature | Current room temperature setpoint | R |
|
||||
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | R/W |
|
||||
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | R/W |
|
||||
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | R |
|
||||
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by thermostat | R |
|
||||
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured at gateway | R/W |
|
||||
| controlsetpoint2 | Number:Temperature | Central heating 2 water setpoint set at boiler | R |
|
||||
| controlsetpoint2requested | Number:Temperature | Central heating 2 water setpoint requested by thermostat | R |
|
||||
| controlsetpoint2override | Number:Temperature | Central heating 2 water setpoint configured at gateway | R/W |
|
||||
| dhwtemp | Number:Temperature | Domestic hot water temperature | R |
|
||||
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | R |
|
||||
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | R/W |
|
||||
| flowtemp | Number:Temperature | Boiler water temperature | R |
|
||||
| returntemp | Number:Temperature | Return water temperature | R |
|
||||
| outsidetemp | Number:Temperature | Outside temperature | R/W |
|
||||
| waterpressure | Number:Pressure | Central heating water pressure | R |
|
||||
| ch_enable | Switch | Central heating enabled set at boiler | R |
|
||||
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | R |
|
||||
| ch_enableoverride | Switch | Central heating enabled overridden at gateway | R |
|
||||
| ch2_enable | Switch | Central heating 2 enabled set at boiler | R |
|
||||
| ch2_enablerequested | Switch | Central heating 2 enabled requested by thermostat | R |
|
||||
| ch2_enableoverride | Switch | Central heating 2 enabled overridden at gateway | R |
|
||||
| ch_mode | Switch | Central heating active | R |
|
||||
| dhw_enable | Switch | Domestic hot water enabled | R |
|
||||
| dhw_mode | Switch | Domestic hot water active | R |
|
||||
| flame | Switch | Burner active | R |
|
||||
| modulevel | Number:Dimensionless | Relative modulation level | R |
|
||||
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | R |
|
||||
| fault | Switch | Fault indication | R |
|
||||
| servicerequest | Switch | Service required | R |
|
||||
| lockout-reset | Switch | Lockout-reset enabled | R |
|
||||
| lowwaterpress | Switch | Low water pressure fault | R |
|
||||
| gasflamefault | Switch | Gas or flame fault | R |
|
||||
| airpressfault | Switch | Air pressure fault | R |
|
||||
| waterovtemp | Switch | Water over-temperature fault | R |
|
||||
| oemfaultcode | Switch | OEM fault code | R |
|
||||
| diag | Switch | Diagr / wstics indication | R |
|
||||
| sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | W |
|
||||
|
||||
## Full Example
|
||||
|
||||
@ -86,6 +92,9 @@ Number:Temperature ConstantRoomSetpointOverride "Constant room setpoint override
|
||||
Number:Temperature ControlSetpoint "Control setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint" }
|
||||
Number:Temperature ControlSetpointRequested "Control setpoint requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointrequested" }
|
||||
Number:Temperature ControlSetpointOverride "Control setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointoverride" }
|
||||
Number:Temperature ControlSetpoint2 "Control setpoint 2 [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2" }
|
||||
Number:Temperature ControlSetpoint2Requested "Control setpoint 2 requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2requested" }
|
||||
Number:Temperature ControlSetpoint2Override "Control setpoint 2 override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2override" }
|
||||
Number:Temperature DomesticHotWaterTemperature "Domestic hot water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:dhwtemp" }
|
||||
Number:Temperature DomesticHotWaterSetpoint "Domestic hot water setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:tdhwset" }
|
||||
Number:Temperature DomesticHotWaterSetpointOverride "Domestic hot water setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:overridedhwsetpoint" }
|
||||
@ -96,6 +105,9 @@ Number:Pressure CentralHeatingWaterPressure "Central heating water pressure [%.1
|
||||
Switch CentralHeatingEnabled "Central heating enabled" <switch> { channel="openthermgateway:otgw:1:ch_enable" }
|
||||
Switch CentralHeatingEnabledRequested "Central heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch_enablerequested" }
|
||||
Switch CentralHeatingEnabledOverride "Central heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch_enableoverride" }
|
||||
Switch CentralHeating2Enabled "Central heating 2 enabled" <switch> { channel="openthermgateway:otgw:1:ch2_enable" }
|
||||
Switch CentralHeating2EnabledRequested "Central 2 heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch2_enablerequested" }
|
||||
Switch CentralHeating2EnabledOverride "Central 2 heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch2_enableoverride" }
|
||||
Switch CentralHeatingActive "Central heating active" <switch> { channel="openthermgateway:otgw:1:ch_mode" }
|
||||
Switch DomesticHotWaterEnabled "Domestic hot water enabled" <switch> { channel="openthermgateway:otgw:1:dhw_enable" }
|
||||
Switch DomesticHotWaterActive "Domestic hot water active" <switch> { channel="openthermgateway:otgw:1:dhw_mode" }
|
||||
@ -153,5 +165,4 @@ sitemap demo label="Main Menu" {
|
||||
Switch item="Diagnostics" icon="" label="Diagnostics indication"
|
||||
}
|
||||
}
|
||||
|
||||
```
|
||||
|
@ -45,10 +45,16 @@ public class OpenThermGatewayBindingConstants {
|
||||
public static final String CHANNEL_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpoint";
|
||||
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpointrequested";
|
||||
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpointoverride";
|
||||
public static final String CHANNEL_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2";
|
||||
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2requested";
|
||||
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2override";
|
||||
public static final String CHANNEL_CENTRAL_HEATING_WATER_PRESSURE = "waterpressure";
|
||||
public static final String CHANNEL_CENTRAL_HEATING_ENABLED = "ch_enable";
|
||||
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING_ENABLED = "ch_enablerequested";
|
||||
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED = "ch_enableoverride";
|
||||
public static final String CHANNEL_CENTRAL_HEATING2_ENABLED = "ch2_enable";
|
||||
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING2_ENABLED = "ch2_enablerequested";
|
||||
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED = "ch2_enableoverride";
|
||||
public static final String CHANNEL_CENTRAL_HEATING_MODE = "ch_mode";
|
||||
public static final String CHANNEL_DOMESTIC_HOT_WATER_TEMPERATURE = "dhwtemp";
|
||||
public static final String CHANNEL_DOMESTIC_HOT_WATER_ENABLED = "dhw_enable";
|
||||
@ -71,8 +77,11 @@ public class OpenThermGatewayBindingConstants {
|
||||
CHANNEL_FLOW_TEMPERATURE, CHANNEL_RETURN_TEMPERATURE, CHANNEL_OUTSIDE_TEMPERATURE,
|
||||
CHANNEL_CENTRAL_HEATING_WATER_PRESSURE, CHANNEL_CENTRAL_HEATING_ENABLED,
|
||||
CHANNEL_REQUESTED_CENTRAL_HEATING_ENABLED, CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED,
|
||||
CHANNEL_CENTRAL_HEATING_MODE, CHANNEL_CENTRAL_HEATING_WATER_SETPOINT,
|
||||
CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT,
|
||||
CHANNEL_CENTRAL_HEATING2_ENABLED, CHANNEL_REQUESTED_CENTRAL_HEATING2_ENABLED,
|
||||
CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED, CHANNEL_CENTRAL_HEATING_MODE,
|
||||
CHANNEL_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT,
|
||||
CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_CENTRAL_HEATING2_WATER_SETPOINT,
|
||||
CHANNEL_REQUESTED_CENTRAL_HEATING2_WATER_SETPOINT, CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT,
|
||||
CHANNEL_DOMESTIC_HOT_WATER_TEMPERATURE, CHANNEL_DOMESTIC_HOT_WATER_ENABLED, CHANNEL_DOMESTIC_HOT_WATER_MODE,
|
||||
CHANNEL_DOMESTIC_HOT_WATER_SETPOINT, CHANNEL_FLAME, CHANNEL_RELATIVE_MODULATION_LEVEL,
|
||||
CHANNEL_MAXIMUM_MODULATION_LEVEL, CHANNEL_FAULT, CHANNEL_SERVICEREQUEST, CHANNEL_REMOTE_RESET,
|
||||
|
@ -118,6 +118,13 @@ public class OpenThermGatewayHandler extends BaseThingHandler implements OpenThe
|
||||
}
|
||||
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED,
|
||||
OnOffType.from(!gatewayCommand.getMessage().equals("0.0")));
|
||||
} else if (code == GatewayCommandCode.ControlSetpoint2) {
|
||||
if (gatewayCommand.getMessage().equals("0.0")) {
|
||||
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT,
|
||||
UnDefType.UNDEF);
|
||||
}
|
||||
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED,
|
||||
OnOffType.from(!gatewayCommand.getMessage().equals("0.0")));
|
||||
}
|
||||
} else {
|
||||
connect();
|
||||
@ -274,6 +281,10 @@ public class OpenThermGatewayHandler extends BaseThingHandler implements OpenThe
|
||||
return GatewayCommandCode.ControlSetpoint;
|
||||
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED:
|
||||
return GatewayCommandCode.CentralHeating;
|
||||
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT:
|
||||
return GatewayCommandCode.ControlSetpoint2;
|
||||
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED:
|
||||
return GatewayCommandCode.CentralHeating2;
|
||||
case OpenThermGatewayBindingConstants.CHANNEL_SEND_COMMAND:
|
||||
return null;
|
||||
default:
|
||||
|
@ -40,6 +40,8 @@ public class DataItemGroup {
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 2, "cooling_enabled", CodeType.B),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 3, "otc_active", CodeType.B),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enable", CodeType.B),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enablerequested", CodeType.T),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enableoverride", CodeType.R),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 5, "0x00:5", CodeType.B),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 6, "0x00:6", CodeType.B),
|
||||
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 7, "0x00:7", CodeType.B),
|
||||
@ -104,7 +106,13 @@ public class DataItemGroup {
|
||||
new DataItem(6, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 6, "0x06:h6"),
|
||||
new DataItem(6, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 7, "0x06:h7") });
|
||||
g.put(7, new DataItem[] { new DataItem(7, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "0x07") });
|
||||
g.put(8, new DataItem[] { new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2") });
|
||||
g.put(8, new DataItem[] {
|
||||
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2", SIUnits.CELSIUS,
|
||||
CodeType.B),
|
||||
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2requested",
|
||||
SIUnits.CELSIUS, CodeType.T),
|
||||
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2override",
|
||||
SIUnits.CELSIUS, CodeType.R) });
|
||||
g.put(9, new DataItem[] { new DataItem(9, Msg.READ, ByteType.BOTH, DataType.FLOAT, 0, "overridesetpoint") });
|
||||
g.put(10, new DataItem[] { new DataItem(10, Msg.WRITE, ByteType.HIGHBYTE, DataType.UINT8, 0, "0x0a:h"),
|
||||
new DataItem(10, Msg.WRITE, ByteType.LOWBYTE, DataType.UINT8, 0, "0x0a:l") });
|
||||
|
@ -120,6 +120,7 @@ public class GatewayCommand {
|
||||
c.put(GatewayCommandCode.GpioA, "0,1,2,3,4,5,6,7");
|
||||
c.put(GatewayCommandCode.GpioB, "0,1,2,3,4,5,6,7");
|
||||
c.put(GatewayCommandCode.SetBack, null);
|
||||
c.put(GatewayCommandCode.TemperatureSensor, "O,R");
|
||||
c.put(GatewayCommandCode.AddAlternative, null);
|
||||
c.put(GatewayCommandCode.DeleteAlternative, null);
|
||||
c.put(GatewayCommandCode.UnknownID, null);
|
||||
@ -131,7 +132,9 @@ public class GatewayCommand {
|
||||
c.put(GatewayCommandCode.SetpointWater, null);
|
||||
c.put(GatewayCommandCode.MaximumModulation, null);
|
||||
c.put(GatewayCommandCode.ControlSetpoint, null);
|
||||
c.put(GatewayCommandCode.ControlSetpoint2, null);
|
||||
c.put(GatewayCommandCode.CentralHeating, "0,1");
|
||||
c.put(GatewayCommandCode.CentralHeating2, "0,1");
|
||||
c.put(GatewayCommandCode.VentilationSetpoint, null);
|
||||
c.put(GatewayCommandCode.Reset, null);
|
||||
c.put(GatewayCommandCode.IgnoreTransition, "0,1");
|
||||
|
@ -38,6 +38,7 @@ public class GatewayCommandCode {
|
||||
public static final String GpioA = "GA";
|
||||
public static final String GpioB = "GB";
|
||||
public static final String SetBack = "SB";
|
||||
public static final String TemperatureSensor = "TS";
|
||||
public static final String AddAlternative = "AA";
|
||||
public static final String DeleteAlternative = "DA";
|
||||
public static final String UnknownID = "UI";
|
||||
@ -49,7 +50,9 @@ public class GatewayCommandCode {
|
||||
public static final String SetpointWater = "SW";
|
||||
public static final String MaximumModulation = "MM";
|
||||
public static final String ControlSetpoint = "CS";
|
||||
public static final String ControlSetpoint2 = "C2";
|
||||
public static final String CentralHeating = "CH";
|
||||
public static final String CentralHeating2 = "H2";
|
||||
public static final String VentilationSetpoint = "VS";
|
||||
public static final String Reset = "RS";
|
||||
public static final String IgnoreTransition = "IT";
|
||||
|
@ -60,6 +60,30 @@
|
||||
<state readOnly="false" min="0" max="100" step="0.1" pattern="%.1f %unit%"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="controlsetpoint2">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Control Setpoint 2</label>
|
||||
<description>Central heating 2 water setpoint set at boiler</description>
|
||||
<category>Temperature</category>
|
||||
<state readOnly="true" pattern="%.1f %unit%"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="controlsetpoint2requested">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Control Setpoint 2 Requested</label>
|
||||
<description>Central heating 2 water setpoint requested by Thermostat</description>
|
||||
<category>Temperature</category>
|
||||
<state readOnly="true" pattern="%.1f %unit%"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="controlsetpoint2override">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Control Setpoint 2 Override</label>
|
||||
<description>Central heating 2 water setpoint configured on OTGW</description>
|
||||
<category>Temperature</category>
|
||||
<state readOnly="false" min="0" max="100" step="0.1" pattern="%.1f %unit%"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="dhwtemp">
|
||||
<item-type>Number:Temperature</item-type>
|
||||
<label>Domestic Hot Water Temperature</label>
|
||||
@ -133,6 +157,28 @@
|
||||
<item-type>Switch</item-type>
|
||||
<label>Central Heating Overridden</label>
|
||||
<description>Central heating enabled overridden at OTGW</description>
|
||||
<state readOnly="false"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="ch2_enable">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Central Heating 2 Enabled</label>
|
||||
<description>Central heating 2 enabled set at boiler</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="ch2_enablerequested">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Central Heating 2 Enabled Thermostat</label>
|
||||
<description>Central heating 2 enabled requested by thermostat</description>
|
||||
<state readOnly="true"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="ch2_enableoverride">
|
||||
<item-type>Switch</item-type>
|
||||
<label>Central Heating 2 Overridden</label>
|
||||
<description>Central heating 2 enabled overridden at OTGW</description>
|
||||
<state readOnly="false"/>
|
||||
</channel-type>
|
||||
|
||||
<channel-type id="ch_mode">
|
||||
|
@ -14,6 +14,9 @@
|
||||
<channel id="controlsetpoint" typeId="controlsetpoint"/>
|
||||
<channel id="controlsetpointrequested" typeId="controlsetpointrequested"/>
|
||||
<channel id="controlsetpointoverride" typeId="controlsetpointoverride"/>
|
||||
<channel id="controlsetpoint2" typeId="controlsetpoint2"/>
|
||||
<channel id="controlsetpoint2requested" typeId="controlsetpoint2requested"/>
|
||||
<channel id="controlsetpoint2override" typeId="controlsetpoint2override"/>
|
||||
<channel id="dhwtemp" typeId="dhwtemp"/>
|
||||
<channel id="tdhwset" typeId="tdhwset"/>
|
||||
<channel id="overridedhwsetpoint" typeId="overridedhwsetpoint"/>
|
||||
@ -24,6 +27,9 @@
|
||||
<channel id="ch_enable" typeId="ch_enable"/>
|
||||
<channel id="ch_enablerequested" typeId="ch_enablerequested"/>
|
||||
<channel id="ch_enableoverride" typeId="ch_enableoverride"/>
|
||||
<channel id="ch2_enable" typeId="ch2_enable"/>
|
||||
<channel id="ch2_enablerequested" typeId="ch2_enablerequested"/>
|
||||
<channel id="ch2_enableoverride" typeId="ch2_enableoverride"/>
|
||||
<channel id="ch_mode" typeId="ch_mode"/>
|
||||
<channel id="dhw_enable" typeId="dhw_enable"/>
|
||||
<channel id="dhw_mode" typeId="dhw_mode"/>
|
||||
@ -41,7 +47,7 @@
|
||||
<channel id="sendcommand" typeId="sendcommand"/>
|
||||
</channels>
|
||||
<properties>
|
||||
<property name="version">1.1.1</property>
|
||||
<property name="version">1.2.0</property>
|
||||
</properties>
|
||||
<config-description-ref uri="thing-type:openthermgateway:otgw"/>
|
||||
</thing-type>
|
||||
|
Loading…