mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-10 15:11:59 +01:00
DSMR identifier cosem objects should be parsed as hex values (#12756)
Closes #12724 Signed-off-by: Hilbrand Bouwkamp <hilbrand@h72.nl>
This commit is contained in:
parent
25a923be39
commit
e6cc323723
@ -54,7 +54,7 @@ public enum CosemObjectType {
|
||||
METER_VALVE_SWITCH_POSITION(new OBISIdentifier(0, 24, 4, 0), CosemDecimal.INSTANCE),
|
||||
|
||||
/* Electricity Meter */
|
||||
EMETER_EQUIPMENT_IDENTIFIER_V2_X(new OBISIdentifier(0, 42, 0, 0), CosemString.INSTANCE),
|
||||
EMETER_EQUIPMENT_IDENTIFIER_V2_X(new OBISIdentifier(0, 42, 0, 0), CosemHexString.INSTANCE),
|
||||
EMETER_EQUIPMENT_IDENTIFIER(new OBISIdentifier(0, 96, 1, 1), CosemHexString.INSTANCE),
|
||||
EMETER_VALUE(new OBISIdentifier(0, 24, 2, 1, true), CosemDate.INSTANCE, CosemQuantity.KILO_WATT_HOUR),
|
||||
EMETER_DELIVERY_TARIFF0(new OBISIdentifier(1, 1, 8, 0), CosemQuantity.KILO_WATT_HOUR),
|
||||
@ -102,7 +102,7 @@ public enum CosemObjectType {
|
||||
EMETER_INSTANT_VOLTAGE_L3(new OBISIdentifier(1, 72, 7, 0), CosemQuantity.VOLT),
|
||||
|
||||
/* Gas Meter */
|
||||
GMETER_EQUIPMENT_IDENTIFIER_V2(new OBISIdentifier(7, 0, 0, 0), CosemString.INSTANCE),
|
||||
GMETER_EQUIPMENT_IDENTIFIER_V2(new OBISIdentifier(7, 0, 0, 0), CosemHexString.INSTANCE),
|
||||
GMETER_24H_DELIVERY_V2(new OBISIdentifier(7, 23, 1, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
|
||||
GMETER_24H_DELIVERY_COMPENSATED_V2(new OBISIdentifier(7, 23, 2, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
|
||||
GMETER_LAST_VALUE(new OBISIdentifier(0, 24, 2, 3), CosemDate.INSTANCE, CosemQuantity.CUBIC_METRE),
|
||||
@ -117,15 +117,15 @@ public enum CosemObjectType {
|
||||
GMETER_VALVE_POSITION_V2_2(new OBISIdentifier(7, 24, 4, 0), CosemDecimal.INSTANCE),
|
||||
|
||||
/* Heating Meter */
|
||||
HMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(5, 0, 0, 0), CosemString.INSTANCE),
|
||||
HMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(5, 0, 0, 0), CosemHexString.INSTANCE),
|
||||
HMETER_VALUE_V2(new OBISIdentifier(5, 1, 0, 0), CosemQuantity.GIGA_JOULE, CosemDate.INSTANCE),
|
||||
|
||||
/* Cooling Meter */
|
||||
CMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(6, 0, 0, 0), CosemString.INSTANCE),
|
||||
CMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(6, 0, 0, 0), CosemHexString.INSTANCE),
|
||||
CMETER_VALUE_V2(new OBISIdentifier(6, 1, 0, 0), CosemQuantity.GIGA_JOULE, CosemDate.INSTANCE),
|
||||
|
||||
/* Water Meter */
|
||||
WMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(8, 0, 0, 0), CosemString.INSTANCE),
|
||||
WMETER_EQUIPMENT_IDENTIFIER_V2_2(new OBISIdentifier(8, 0, 0, 0), CosemHexString.INSTANCE),
|
||||
WMETER_VALUE_V2(new OBISIdentifier(8, 1, 0, 0), CosemQuantity.CUBIC_METRE, CosemDate.INSTANCE),
|
||||
WMETER_VALUE_V3(new OBISIdentifier(0, 24, 3, 0, true), CosemQuantity.CUBIC_METRE),
|
||||
|
||||
|
Loading…
Reference in New Issue