mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-25 14:55:55 +01:00
[fronius] Add the new channels to the documentation (#12394)
* [fronius] Document the recently added inverter power and soc channels Signed-off-by: Jimmy Tanagra <jcode@tanagra.id.au>
This commit is contained in:
parent
39ebfe2b07
commit
e6179aafa2
@ -15,9 +15,8 @@ It supports Fronius inverters and Fronius Smart Meter. Supports:
|
||||
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||||
| `bridge` | The Bridge |
|
||||
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
|
||||
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0)
|
||||
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0)
|
||||
|
||||
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0) |
|
||||
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0) |
|
||||
|
||||
## Discovery
|
||||
|
||||
@ -50,30 +49,33 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
|
||||
### Ohmpilot Thing Configuration
|
||||
|
||||
| Parameter | Description |
|
||||
| ---------- | ----------------------------------------------- |
|
||||
| Parameter | Description |
|
||||
| ---------- | -------------------------------------------- |
|
||||
| `deviceId` | The identifier of your ohmpilot (Default: 0) |
|
||||
|
||||
## Channels
|
||||
|
||||
### Channels for `powerinverter` Thing
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
| ------------------------------------ | --------- | ----------------------------------------------------------------------------------------------------------------- |
|
||||
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
|
||||
| `inverterdatachannelpac` | Number | AC power |
|
||||
| `inverterdatachanneltotal` | Number | Energy generated overall |
|
||||
| `inverterdatachannelyear` | Number | Energy generated in current year |
|
||||
| `inverterdatachannelfac` | Number | AC frequency |
|
||||
| `inverterdatachanneliac` | Number | AC current |
|
||||
| `inverterdatachannelidc` | Number | DC current |
|
||||
| `inverterdatachanneluac` | Number | AC voltage |
|
||||
| `inverterdatachanneludc` | Number | DC voltage |
|
||||
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
|
||||
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
||||
| `powerflowchannelpgrid` | Number | Power + from grid, - to grid |
|
||||
| `powerflowchannelpload` | Number | Power + generator, - consumer |
|
||||
| `powerflowchannelpakku` | Number | Power + charge, - discharge |
|
||||
| Channel ID | Item Type | Description |
|
||||
| ------------------------------------ | -------------------- | ----------------------------------------------------------------------------------------------------------------- |
|
||||
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
|
||||
| `inverterdatachannelpac` | Number | AC power |
|
||||
| `inverterdatachanneltotal` | Number | Energy generated overall |
|
||||
| `inverterdatachannelyear` | Number | Energy generated in current year |
|
||||
| `inverterdatachannelfac` | Number | AC frequency |
|
||||
| `inverterdatachanneliac` | Number | AC current |
|
||||
| `inverterdatachannelidc` | Number | DC current |
|
||||
| `inverterdatachanneluac` | Number | AC voltage |
|
||||
| `inverterdatachanneludc` | Number | DC voltage |
|
||||
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
|
||||
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
|
||||
| `powerflowchannelpgrid` | Number:Power | Power (+ from grid, - to grid) |
|
||||
| `powerflowchannelpload` | Number:Power | Power (+ generator, - consumer) |
|
||||
| `powerflowchannelpakku` | Number:Power | Power (+ charge, - discharge) |
|
||||
| `powerflowchannelppv` | Number:Power | Power (+ production) |
|
||||
| `powerflowinverter1power` | Number:Power | Current power of inverter 1, null if not running (+ produce/export, - consume/import) |
|
||||
| `powerflowinverter1soc` | Number:Dimensionless | Current state of charge of inverter 1 in percent |
|
||||
|
||||
### Channels for `meter` Thing
|
||||
|
||||
@ -90,7 +92,7 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
|
||||
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
|
||||
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
|
||||
| `powerrealsum` | Number:Power | Real Power summed up |
|
||||
| `powerrealsum` | Number:Power | Real Power summed up |
|
||||
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
|
||||
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
|
||||
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
|
||||
@ -101,13 +103,13 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
|
||||
### Channels for `ohmpilot` Thing
|
||||
|
||||
| Channel ID | Item Type | Description |
|
||||
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
||||
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
||||
| `powerrealsum` | Number:Power | Real Power |
|
||||
| `temperaturechannel1` | Number:Temperature | Temperature |
|
||||
| `errorcode` | Number | Device error code |
|
||||
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
|
||||
| Channel ID | Item Type | Description |
|
||||
| ----------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|
||||
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
|
||||
| `powerrealsum` | Number:Power | Real Power |
|
||||
| `temperaturechannel1` | Number:Temperature | Temperature |
|
||||
| `errorcode` | Number | Device error code |
|
||||
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
|
||||
| |
|
||||
|
||||
|
||||
@ -115,16 +117,16 @@ The binding has no configuration options, all configuration is done at `bridge`,
|
||||
|
||||
### The `meter` thing has the following properties:
|
||||
|
||||
| Property | Description |
|
||||
| -------- | ------------------------------ |
|
||||
| `modelId` | The model name of the meter |
|
||||
| Property | Description |
|
||||
| -------------- | ------------------------------ |
|
||||
| `modelId` | The model name of the meter |
|
||||
| `serialNumber` | The serial number of the meter |
|
||||
|
||||
### The `ohmpilot` thing has the following property:
|
||||
|
||||
| Property | Description |
|
||||
| -------- | ------------------------------ |
|
||||
| `modelId` | The model name of the ohmpilot |
|
||||
| Property | Description |
|
||||
| -------------- | --------------------------------- |
|
||||
| `modelId` | The model name of the ohmpilot |
|
||||
| `serialNumber` | The serial number of the ohmpilot |
|
||||
|
||||
## Full Example
|
||||
@ -153,9 +155,12 @@ Number UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachan
|
||||
Number UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
|
||||
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
|
||||
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
|
||||
Number Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
|
||||
Number Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
|
||||
Number Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
|
||||
Number:Power Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
|
||||
Number:Power Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
|
||||
Number:Power Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
|
||||
Number:Power Production_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelppv" }
|
||||
Number:Power Inverter1_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1power" }
|
||||
Number:Dimensionless Inverter1_SOC { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1soc" }
|
||||
|
||||
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
|
||||
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
|
||||
|
Loading…
Reference in New Issue
Block a user