Renamed channel manual_fan_speed to manual_fan_step for consistency. (#11147)

Fixes #10621

Signed-off-by: Jacob Laursen <jacob-github@vindvejr.dk>
This commit is contained in:
jlaur 2021-08-24 18:59:35 +02:00 committed by GitHub
parent 5cb228570d
commit be17654767
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
4 changed files with 20 additions and 9 deletions

View File

@ -24,7 +24,7 @@ These are the available configuration parameters:
|---|---|---|---|---|
| current_time | main | DateTime | RO | Current time reported by the air unit. |
| mode | main | String | RW | Value to control the operation mode of the air unit. One of DEMAND, PROGRAM, MANUAL and OFF |
| manual_fan_speed | main | Dimmer | RW | Value to control the fan speed when in MANUAL mode (10 steps) |
| manual_fan_step | main | Dimmer | RW | Value to control the fan step when in MANUAL mode (10 steps) |
| supply_fan_speed | main | Number | RO | Current rotation of the fan supplying air to the rooms (in rpm) |
| extract_fan_speed | main | Number | RO | Current rotation of the fan extracting air from the rooms (in rpm) |
| supply_fan_step | main | Dimmer | RO | Current step setting of the fan supplying air to the rooms |
@ -34,7 +34,7 @@ These are the available configuration parameters:
| room_temp | temps | Number:Temperature | RO | Temperature of the air in the room of the Air Dial |
| room_temp_calculated | temps | Number:Temperature | RO | Calculated Room Temperature |
| outdoor_temp | temps | Number:Temperature | RO | Temperature of the air outside |
| humidity | humidity | Number:Dimensionless | RO | Current relative humidity measured by the unit |
| humidity | humidity | Number:Dimensionless | RO | Current relative humidity measured by the air unit |
| bypass | recuperator | Switch | RW | Disables the heat exchange. Useful in summer when room temperature is above target and outside temperature is below target. |
| supply_temp | recuperator | Number | RO | Temperature of air which is passed to the rooms |
| extract_temp | recuperator | Number | RO | Temperature of the air as extracted from the rooms |

View File

@ -28,8 +28,11 @@ public enum Channel {
CHANNEL_CURRENT_TIME("current_time", ChannelGroup.MAIN, DanfossAirUnit::getCurrentTime),
CHANNEL_MODE("mode", ChannelGroup.MAIN, DanfossAirUnit::getMode, DanfossAirUnit::setMode),
CHANNEL_MANUAL_FAN_SPEED("manual_fan_speed", ChannelGroup.MAIN, DanfossAirUnit::getManualFanSpeed,
DanfossAirUnit::setManualFanSpeed),
// Backwards compatibility as channel was renamed from manual_fan_speed to manual_fan_step.
CHANNEL_MANUAL_FAN_SPEED("manual_fan_speed", ChannelGroup.MAIN, DanfossAirUnit::getManualFanStep,
DanfossAirUnit::setManualFanStep),
CHANNEL_MANUAL_FAN_STEP("manual_fan_step", ChannelGroup.MAIN, DanfossAirUnit::getManualFanStep,
DanfossAirUnit::setManualFanStep),
CHANNEL_EXTRACT_FAN_SPEED("extract_fan_speed", ChannelGroup.MAIN, DanfossAirUnit::getExtractFanSpeed),
CHANNEL_SUPPLY_FAN_SPEED("supply_fan_speed", ChannelGroup.MAIN, DanfossAirUnit::getSupplyFanSpeed),
CHANNEL_EXTRACT_FAN_STEP("extract_fan_step", ChannelGroup.MAIN, DanfossAirUnit::getExtractFanStep),

View File

@ -161,7 +161,7 @@ public class DanfossAirUnit {
return new StringType(Mode.values()[getByte(REGISTER_1_READ, MODE)].name());
}
public PercentType getManualFanSpeed() throws IOException {
public PercentType getManualFanStep() throws IOException {
return new PercentType(BigDecimal.valueOf(getByte(REGISTER_1_READ, MANUAL_FAN_SPEED_STEP) * 10));
}
@ -242,7 +242,7 @@ public class DanfossAirUnit {
return new DateTimeType(timestamp);
}
public PercentType setManualFanSpeed(Command cmd) throws IOException {
public PercentType setManualFanStep(Command cmd) throws IOException {
return setPercentTypeRegister(cmd, MANUAL_FAN_SPEED_STEP);
}

View File

@ -48,6 +48,7 @@
<channels>
<channel id="current_time" typeId="currentTime"/>
<channel id="mode" typeId="mode"/>
<channel id="manual_fan_step" typeId="manualFanStep"/>
<channel id="manual_fan_speed" typeId="manualFanSpeed"/>
<channel id="supply_fan_speed" typeId="supplyFanSpeed"/>
<channel id="extract_fan_speed" typeId="extractFanSpeed"/>
@ -85,7 +86,7 @@
<label>Humidity</label>
<channels>
<channel id="humidity" typeId="humidity">
<description>Current relative humidity measured by the unit</description>
<description>Current relative humidity measured by the air unit</description>
</channel>
</channels>
</channel-group-type>
@ -147,10 +148,17 @@
</options>
</state>
</channel-type>
<channel-type id="manualFanSpeed">
<channel-type id="manualFanStep">
<item-type>Dimmer</item-type>
<label>Manual Fan Step</label>
<description>Controls 10-step setting of the fan when operation mode is manual</description>
<category>Fan</category>
<state step="10" min="0" max="100"/>
</channel-type>
<channel-type id="manualFanSpeed" advanced="true">
<item-type>Dimmer</item-type>
<label>Manual Fan Speed</label>
<description>Controls 10-step setting of the fan when operation mode is manual</description>
<description>Deprecated, please use Manual Fan Step instead. This channel will be removed in a later version.</description>
<category>Fan</category>
<state step="10" min="0" max="100"/>
</channel-type>