[openwebnet] Thermo: Fixed handling of mode=AUTO for bus_thermo_zone (#16534)

* [openwebnet] improved Thermo mode/weekly/scenario channels descriptions
* [openwebnet] Fixed handling of mode=AUTO for bus_thermo_zone
Fixes #13754

---------

Signed-off-by: Massimo Valla <mvcode00@gmail.com>
Signed-off-by: Ciprian Pascu <contact@ciprianpascu.ro>
This commit is contained in:
M Valla 2024-03-18 11:49:43 +01:00 committed by Ciprian Pascu
parent 1af986d427
commit 8aff5e98dc
5 changed files with 85 additions and 71 deletions

View File

@ -44,7 +44,7 @@ The following Things and OpenWebNet `WHOs` are supported:
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work | Successfully tested: F452, F453, F453AV,F454, F455, MyHOMEServer1, MyHOME_Screen10, MyHOME_Screen3,5, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202  |
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes) | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455; Central Units (4 or 99 zones) are not fully supported yet. See [Channels - Thermo](#configuring-thermo) for more details |
| Temperature Control | `4` | `bus_thermo_zone`, `bus_thermo_sensor`, `bus_thermo_cu` | Thermo zones management and temperature sensors (probes) | Successfully tested: H/LN4691, HS4692, KG4691; thermo sensors: L/N/NT4577 + 3455. Partially tested: Central Units 4-zones (models L/N/NT/HD/HC/HS4695) and 99-zones (model 3550). See [Channels - Thermo](#configuring-thermo) for more details |
| Alarm | `5` | `bus_alarm_system`, `bus_alarm_zone` | BUS Alarm system and zones | Successfully tested: Burglar-alarm Unit 3486 |
| Auxiliary (AUX) | `9` | `bus_aux` | AUX commands | Successfully tested: AUX configured for Burglar-alarm Unit 3486. **Only sending AUX commands is supported** |
| Basic, CEN & CEN+ Scenarios | `0`, `15`, `25` | `bus_scenario_control`, `bus_cen_scenario_control`, `bus_cenplus_scenario_control` | Basic and CEN/CEN+ Scenarios events and virtual activation | Successfully tested: CEN/CEN+ scenario control: HC/HD/HS/L/N/NT4680 and basic scenario modules F420/IR3456 + L4680 (WHO=0) |
@ -159,11 +159,12 @@ Temperature sensors can be configured defining a `bus_thermo_sensor` Thing with
- example sensor `5` of external zone `00` --> `where="500"`
- example: slave sensor `3` of zone `2` --> `where="302"`
The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing with the `where` configuration parameter (`OpenWebNet Address`) set to `where="#0"` for a 99-zone Central Unit or `where="#0#1"` for a 4-zone Central Unit configured as zone 1.
The (optional) Central Unit can be configured defining a `bus_themo_cu` Thing with the `where` configuration parameter (`OpenWebNet Address`) set to `where="#0"` for a 99-zone Central Unit (model 3550) or `where="#0#1"` for a 4-zone Central Unit (models L/N/NT/HD/HC/HS 4695) configured as zone 1.
##### Thermo Central Unit integration missing points
##### Thermo Central Unit integration known limitations
- Read setPoint temperature and current mode
- Central Unit Programming and Customisations settings (T1/2/3 temperature levels, date & time, weekly/scenarios/holiday programming, etc.)
- Holiday/Vacation activation command
#### Configuring Alarm and Auxiliary (AUX)
@ -244,7 +245,7 @@ OPEN command to execute: *5*8#134##
| `temperature` | `bus_thermo_zone`, `bus_thermo_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
| `setpointTemperature` | `bus_thermo_zone`, `bus_thermo_cu` | Number:Temperature | The zone or Central Unit setpoint temperature | R/W | N |
| `function` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set thermo function (`COOLING`, `HEATING`, `GENERIC`) or the Central Unit thermo function (`COOLING`, `HEATING`) | R/W | N |
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode ( `MANUAL`, `PROTECTION`, `OFF`, `WEEKLY`, `SCENARIO`) | R/W | N |
| `mode` | `bus_thermo_zone`, `bus_thermo_cu` | String | The zone set mode (`AUTO`, `MANUAL`, `PROTECTION`, `OFF`) or the Central Unit set mode (`WEEKLY`, `SCENARIO`, `MANUAL`, `PROTECTION`, `OFF`) | R/W | N |
| `speedFanCoil` | `bus_thermo_zone` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
| `actuators` | `bus_thermo_zone` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
| `heatingValves` | `bus_thermo_zone` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
@ -252,8 +253,8 @@ OPEN command to execute: *5*8#134##
| `localOffset` | `bus_thermo_zone` | String | The zone local offset status: `OFF`, `PROTECTION`, `MINUS_3`, `MINUS_2` , `MINUS_1`, `NORMAL`, `PLUS_1`, `PLUS_2`, `PLUS_3` | R | Y |
| `remoteControl` | `bus_thermo_cu` | String | The Central Unit Remote Control status: `ENABLED`, `DISABLED` | R | Y |
| `batteryStatus` | `bus_thermo_cu` | String | The Central Unit Battery status: `OK`, `KO` | R | Y |
| `weeklyProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
| `scenarioProgram` | `bus_thermo_cu` | Number | The program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
| `weeklyProgram` | `bus_thermo_cu` | Number | The weekly program number (`1`, `2`, `3`) when Central Unit mode is `WEEKLY` | R/W | N |
| `scenarioProgram` | `bus_thermo_cu` | Number | The scenario program number (`1`, `2`, ... , `16`) when Central Unit mode is `SCENARIO` | R/W | N |
| `failureDiscovered` | `bus_thermo_cu` | Switch | Indicates if a Failure was discovered by the Central Unit: `ON`, `OFF` | R | Y |
| `atLeastOneProbeOff` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in OFF mode: `ON`, `OFF` | R | Y |
| `atLeastOneProbeProtection` | `bus_thermo_cu` | Switch | Indicates if at least one probe is in PROTECTION mode: `ON`, `OFF` | R | Y |
@ -305,16 +306,16 @@ See [openwebnet.sitemap](#openwebnet-sitemap) & [openwebnet.rules](#openwebnet-r
- `EXTENDED_PRESS` - sent after `START_EXTENDED_PRESS` if you keep the button pressed longer; will be sent again every 0,5sec as long as you hold pressed (good for rules involving dimming/volume)
- `RELEASE_EXTENDED_PRESS` - sent once when you finally release the button after having it pressed longer than 0,5sec
#### `mode` for values WEEKLY and SCENARIO (thermo Central Unit)
#### Thermo Central Unit `mode`: `WEEKLY` and `SCENARIO`
There are three WEEKLY and sixteen SCENARIO programs defined for the thermo Central Unit.
In order to activate one of them you have to use two different channels:
In order to activate one specific weekly or scenario program two different channels must be used:
- with `mode` you can set the mode (`WEEKLY` or `SCENARIO`)
- with `weeklyProgram` (if `WEEKLY` was set) or with `scenarioProgram` (if `SCENARIO` was set) you can set the program number
- with the `mode` channel it's possible to set the mode (`WEEKLY` or `SCENARIO`)
- with `weeklyProgram` (if `WEEKLY` was set) or `scenarioProgram` (if `SCENARIO` was set) channels you can set the specific weekly/scenario program number
Example: if you want to activate SCENARIO number 9 on the thermo Central Unit you have to set `mode` = `SCENARIO` and `scenarioProgram` = `9`.
Example: if you want to activate SCENARIO number 9 on the thermo Central Unit you have to set channel `mode` = `SCENARIO` and channel `scenarioProgram` = `9`.
## Full Example

View File

@ -87,6 +87,8 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
private static final String CU_REMOTE_CONTROL_DISABLED = "DISABLED";
private static final String CU_BATTERY_OK = "OK";
private static final String CU_BATTERY_KO = "KO";
private static final String MODE_WEEKLY = "WEEKLY";
private static final String MODE_AUTO = "AUTO";
public OpenWebNetThermoregulationHandler(Thing thing) {
super(thing);
@ -253,7 +255,7 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
if (isCentralUnit && WhatThermo.isComplex(command.toString())) {
int programNumber = 0;
if ("WEEKLY".equalsIgnoreCase(command.toString())) {
if (MODE_WEEKLY.equalsIgnoreCase(command.toString())) {
programNumber = currentWeeklyPrgNum;
} else {
programNumber = currentScenarioPrgNum;
@ -261,7 +263,11 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
newMode = Thermoregulation.OperationMode.valueOf(command.toString() + "_" + programNumber);
currentMode = newMode;
} else {
newMode = Thermoregulation.OperationMode.valueOf(command.toString());
if (MODE_AUTO.equalsIgnoreCase(command.toString())) {
newMode = Thermoregulation.OperationMode.PROGRAM;
} else {
newMode = Thermoregulation.OperationMode.valueOf(command.toString());
}
}
send(Thermoregulation.requestWriteMode(getWhere(w.value()), newMode, currentFunction,
currentSetPointTemp));
@ -418,7 +424,13 @@ public class OpenWebNetThermoregulationHandler extends OpenWebNetThingHandler {
// must convert from OperationMode to Mode and set ProgramNumber when necessary
if (operationMode != null) {
updateState(CHANNEL_MODE, new StringType(operationMode.mode()));
String newMode;
if (operationMode == Thermoregulation.OperationMode.PROGRAM) { // translate PROGRAM -> AUTO
newMode = MODE_AUTO;
} else {
newMode = operationMode.mode();
}
updateState(CHANNEL_MODE, new StringType(newMode));
Integer programN = 0;
try {
@Nullable

View File

@ -143,11 +143,11 @@ channel-type.openwebnet.alarmZoneState.description = Alarm zone is active (ON) o
channel-type.openwebnet.armedState.label = Armed State
channel-type.openwebnet.armedState.description = Alarm is armed (ON) or disarmed (OFF) (read only).
channel-type.openwebnet.atLeastOneProbeManual.label = At least one probe in MANUAL
channel-type.openwebnet.atLeastOneProbeManual.description = At least one probe in MANUAL indicator in Central Unit (read only)
channel-type.openwebnet.atLeastOneProbeManual.description = At least one probe in MANUAL mode indicator from Central Unit (read only)
channel-type.openwebnet.atLeastOneProbeOff.label = At least one probe OFF
channel-type.openwebnet.atLeastOneProbeOff.description = At least one probe OFF indicator in Central Unit (read only)
channel-type.openwebnet.atLeastOneProbeOff.description = At least one probe in OFF mode indicator from Central Unit (read only)
channel-type.openwebnet.atLeastOneProbeProtection.label = At least one probe in PROTECTION
channel-type.openwebnet.atLeastOneProbeProtection.description = At least one probe in PROTECTION (Antifreeze / Heat Protection) indicator in Central Unit (read only)
channel-type.openwebnet.atLeastOneProbeProtection.description = At least one probe in PROTECTION mode (Antifreeze / Heat Protection) indicator from Central Unit (read only)
channel-type.openwebnet.aux.label = Auxiliary
channel-type.openwebnet.aux.description = Controls an Auxiliary command (read/write)
channel-type.openwebnet.aux.state.option.OFF = Off
@ -200,8 +200,8 @@ channel-type.openwebnet.function.state.option.COOLING = Cooling
channel-type.openwebnet.function.state.option.GENERIC = Generic
channel-type.openwebnet.functionCentralUnit.label = Thermo Function
channel-type.openwebnet.functionCentralUnit.description = Thermo function of the Central Unit (read only)
channel-type.openwebnet.functionCentralUnit.state.option.HEATING = Heating
channel-type.openwebnet.functionCentralUnit.state.option.COOLING = Cooling
channel-type.openwebnet.functionCentralUnit.state.option.HEATING = Winter
channel-type.openwebnet.functionCentralUnit.state.option.COOLING = Summer
channel-type.openwebnet.heatingValves.label = Heating Valves
channel-type.openwebnet.heatingValves.description = Heating Valves status (read only)
channel-type.openwebnet.heatingValves.state.option.OFF = Off
@ -223,23 +223,23 @@ channel-type.openwebnet.localOffset.state.option.PROTECTION = Antifreeze / Heat
channel-type.openwebnet.localOffset.state.option.PLUS_3 = +3
channel-type.openwebnet.localOffset.state.option.PLUS_2 = +2
channel-type.openwebnet.localOffset.state.option.PLUS_1 = +1
channel-type.openwebnet.localOffset.state.option.NORMAL = 0
channel-type.openwebnet.localOffset.state.option.NORMAL = No offset
channel-type.openwebnet.localOffset.state.option.MINUS_1 = -1
channel-type.openwebnet.localOffset.state.option.MINUS_2 = -2
channel-type.openwebnet.localOffset.state.option.MINUS_3 = -3
channel-type.openwebnet.mode.label = Mode
channel-type.openwebnet.mode.description = Set mode of the zone (read/write)
channel-type.openwebnet.mode.state.option.AUTO = Automatic
channel-type.openwebnet.mode.state.option.MANUAL = Manual
channel-type.openwebnet.mode.state.option.PROTECTION = Antifreeze / Heat Protection
channel-type.openwebnet.mode.state.option.OFF = Off
channel-type.openwebnet.mode.state.option.AUTO = Automatic
channel-type.openwebnet.modeCentralUnit.label = Central Unit Mode
channel-type.openwebnet.modeCentralUnit.description = Set mode of the Central Unit (read/write)
channel-type.openwebnet.modeCentralUnit.state.option.WEEKLY = Weekly
channel-type.openwebnet.modeCentralUnit.state.option.SCENARIO = Scenarios
channel-type.openwebnet.modeCentralUnit.state.option.MANUAL = Manual
channel-type.openwebnet.modeCentralUnit.state.option.PROTECTION = Antifreeze / Heat Protection
channel-type.openwebnet.modeCentralUnit.state.option.OFF = Off
channel-type.openwebnet.modeCentralUnit.state.option.WEEKLY = Weekly
channel-type.openwebnet.modeCentralUnit.state.option.SCENARIO = Scenario
channel-type.openwebnet.power.label = Power
channel-type.openwebnet.power.description = Current active power
channel-type.openwebnet.remoteControl.label = Remote Control
@ -250,22 +250,22 @@ channel-type.openwebnet.scenarioEvent.label = Activated Scenario Event
channel-type.openwebnet.scenarioEvent.description = Event corresponding to the number of Basic Scenario that has been activated (read only)
channel-type.openwebnet.scenarioProgramCentralUnit.label = Scenario Program Number
channel-type.openwebnet.scenarioProgramCentralUnit.description = Set scenario program number for the Central Unit, valid only with Central Unit mode = "SCENARIO" (read/write)
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.1 = Program 1
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.2 = Program 2
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.3 = Program 3
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.4 = Program 4
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.5 = Program 5
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.6 = Program 6
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.7 = Program 7
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.8 = Program 8
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.9 = Program 9
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.10 = Program 10
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.11 = Program 11
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.12 = Program 12
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.13 = Program 13
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.14 = Program 14
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.15 = Program 15
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.16 = Program 16
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.1 = Scenario 1
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.2 = Scenario 2
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.3 = Scenario 3
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.4 = Scenario 4
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.5 = Scenario 5
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.6 = Scenario 6
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.7 = Scenario 7
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.8 = Scenario 8
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.9 = Scenario 9
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.10 = Scenario 10
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.11 = Scenario 11
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.12 = Scenario 12
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.13 = Scenario 13
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.14 = Scenario 14
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.15 = Scenario 15
channel-type.openwebnet.scenarioProgramCentralUnit.state.option.16 = Scenario 16
channel-type.openwebnet.setpointTemperature.label = Setpoint Temperature
channel-type.openwebnet.setpointTemperature.description = Setpoint temperature (read/write)
channel-type.openwebnet.shutter.label = Roller Shutter
@ -283,9 +283,9 @@ channel-type.openwebnet.temperature.label = Temperature
channel-type.openwebnet.temperature.description = Current temperature (read only)
channel-type.openwebnet.weeklyProgramCentralUnit.label = Weekly Program Number
channel-type.openwebnet.weeklyProgramCentralUnit.description = Set weekly program number for the Central Unit, valid only with Central Unit mode = "WEEKLY" (read/write)
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.1 = Program 1
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.2 = Program 2
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.3 = Program 3
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.1 = Weekly Program 1
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.2 = Weekly Program 2
channel-type.openwebnet.weeklyProgramCentralUnit.state.option.3 = Weekly Program 3
channel-type.openwebnet.zoneAlarm.label = Zone Alarm
channel-type.openwebnet.zoneAlarm.description = Current alarm for the zone (read only).
channel-type.openwebnet.zoneAlarm.state.option.INTRUSION = Intrusion

View File

@ -31,7 +31,7 @@
<properties>
<property name="vendor">BTicino/Legrand</property>
<property name="model">BTicino Central Unit 3550 (99 zones) or BTI-L/NT/HC/4695 (4 zones) </property>
<property name="model">BTicino Central Unit 3550 (99 zones) or L/N/NT/HD/HC/HS4695 (4 zones) </property>
<property name="ownDeviceType">430</property>
</properties>

View File

@ -95,8 +95,8 @@
<description>Thermo function of the Central Unit (read only)</description>
<state readOnly="true">
<options>
<option value="HEATING">Heating</option>
<option value="COOLING">Cooling</option>
<option value="HEATING">Winter</option>
<option value="COOLING">Summer</option>
</options>
</state>
</channel-type>
@ -119,10 +119,10 @@
<description>Set mode of the zone (read/write)</description>
<state>
<options>
<option value="AUTO">Automatic</option>
<option value="MANUAL">Manual</option>
<option value="PROTECTION">Antifreeze / Heat Protection</option>
<option value="OFF">Off</option>
<option value="AUTO">Automatic</option>
</options>
</state>
</channel-type>
@ -219,7 +219,7 @@
<option value="PLUS_3">+3</option>
<option value="PLUS_2">+2</option>
<option value="PLUS_1">+1</option>
<option value="NORMAL">0</option>
<option value="NORMAL">No offset</option>
<option value="MINUS_1">-1</option>
<option value="MINUS_2">-2</option>
<option value="MINUS_3">-3</option>
@ -233,11 +233,11 @@
<description>Set mode of the Central Unit (read/write)</description>
<state>
<options>
<option value="WEEKLY">Weekly</option>
<option value="SCENARIO">Scenarios</option>
<option value="MANUAL">Manual</option>
<option value="PROTECTION">Antifreeze / Heat Protection</option>
<option value="OFF">Off</option>
<option value="WEEKLY">Weekly</option>
<option value="SCENARIO">Scenario</option>
</options>
</state>
</channel-type>
@ -248,9 +248,9 @@
<description>Set weekly program number for the Central Unit, valid only with Central Unit mode = "WEEKLY" (read/write)</description>
<state>
<options>
<option value="1">Program 1</option>
<option value="2">Program 2</option>
<option value="3">Program 3</option>
<option value="1">Weekly Program 1</option>
<option value="2">Weekly Program 2</option>
<option value="3">Weekly Program 3</option>
</options>
</state>
</channel-type>
@ -262,22 +262,22 @@
(read/write)</description>
<state>
<options>
<option value="1">Program 1</option>
<option value="2">Program 2</option>
<option value="3">Program 3</option>
<option value="4">Program 4</option>
<option value="5">Program 5</option>
<option value="6">Program 6</option>
<option value="7">Program 7</option>
<option value="8">Program 8</option>
<option value="9">Program 9</option>
<option value="10">Program 10</option>
<option value="11">Program 11</option>
<option value="12">Program 12</option>
<option value="13">Program 13</option>
<option value="14">Program 14</option>
<option value="15">Program 15</option>
<option value="16">Program 16</option>
<option value="1">Scenario 1</option>
<option value="2">Scenario 2</option>
<option value="3">Scenario 3</option>
<option value="4">Scenario 4</option>
<option value="5">Scenario 5</option>
<option value="6">Scenario 6</option>
<option value="7">Scenario 7</option>
<option value="8">Scenario 8</option>
<option value="9">Scenario 9</option>
<option value="10">Scenario 10</option>
<option value="11">Scenario 11</option>
<option value="12">Scenario 12</option>
<option value="13">Scenario 13</option>
<option value="14">Scenario 14</option>
<option value="15">Scenario 15</option>
<option value="16">Scenario 16</option>
</options>
</state>
</channel-type>
@ -316,21 +316,22 @@
<channel-type id="atLeastOneProbeOff" advanced="true">
<item-type>Switch</item-type>
<label>At least one probe OFF</label>
<description>At least one probe OFF indicator in Central Unit (read only)</description>
<description>At least one probe in OFF mode indicator from Central Unit (read only)</description>
<state readOnly="true"></state>
</channel-type>
<channel-type id="atLeastOneProbeProtection" advanced="true">
<item-type>Switch</item-type>
<label>At least one probe in PROTECTION</label>
<description>At least one probe in PROTECTION (Antifreeze / Heat Protection) indicator in Central Unit (read only)</description>
<description>At least one probe in PROTECTION mode (Antifreeze / Heat Protection) indicator from Central Unit (read
only)</description>
<state readOnly="true"></state>
</channel-type>
<channel-type id="atLeastOneProbeManual" advanced="true">
<item-type>Switch</item-type>
<label>At least one probe in MANUAL</label>
<description>At least one probe in MANUAL indicator in Central Unit (read only)</description>
<description>At least one probe in MANUAL mode indicator from Central Unit (read only)</description>
<state readOnly="true"></state>
</channel-type>