@ -47,7 +47,8 @@ as multicast traffic is typically not forwarded.
|
||||
|
||||
### IP Gateway
|
||||
|
||||
The IP Gateway is the most commonly used way to connect to the KNX bus. At its base, the _ip_ bridge accepts the following configuration parameters:
|
||||
The IP Gateway is the most commonly used way to connect to the KNX bus.
|
||||
At its base, the _ip_ bridge accepts the following configuration parameters:
|
||||
|
||||
| Name | Required | Description | Default value |
|
||||
|---------------------|--------------|--------------------------------------------------------------------------------------------------------------|------------------------------------------------------|
|
||||
@ -86,9 +87,10 @@ The _serial_ bridge accepts the following configuration parameters:
|
||||
_basic_ Things are wrappers around arbitrary group addresses on the KNX bus.
|
||||
They have no specific function in the KNX binding, except that if the _address_ is defined, the binding will actively poll the Individual Address on the KNX bus to detect that the KNX actuator is reachable.
|
||||
Under normal real-world circumstances, either all devices on a bus are reachable, or the entire bus is down.
|
||||
If line couplers are installed, physical device addressing might be filtered; in this case please do not specify the addresses for devices on this line.
|
||||
When _fetch_ is set to true, the binding will read-out the memory of the KNX actuator in order to detect configuration data and so forth.
|
||||
This is however an experimental feature, very prone to the actual on the KNX bus.
|
||||
If line couplers are installed, physical device addressing might be filtered; in this case, please do not specify the addresses for devices on this line.
|
||||
When _fetch_ is set to true, the binding will read out the memory of the KNX actuator in order to detect configuration data and so forth.
|
||||
This is just for information and has no effect on the functionality of the binding.
|
||||
It can safely be turned off to save bandwidth on the bus or avoid problems with older devices.
|
||||
|
||||
| Name | Required | Description | Default value |
|
||||
|--------------|----------|--------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------|
|
||||
@ -98,7 +100,7 @@ This is however an experimental feature, very prone to the actual on the KNX bus
|
||||
| readInterval | N | Interval (in seconds) to actively request reading of values from the bus (0 if they should only be read once at startup) | 0 |
|
||||
|
||||
Different kinds of channels are defined and can be used to group together Group Addresses.
|
||||
All channels of a device share one configuration parameter defined on device level: _readInterval_, an optional parameter which indicates if 'readable' group addresses of that Channel should be read periodically at the given interval, in seconds.
|
||||
All channels of a device share one configuration parameter defined at the device level: _readInterval_, an optional parameter that indicates if the 'readable' group addresses of that Channel should be read periodically at the given interval, in seconds.
|
||||
'Readable' group addresses are marked with an `<` in the group address definition of a Channel, see below.
|
||||
All readable group addresses are queried by openHAB during startup.
|
||||
If readInterval is not specified or set to 0, no further periodic reading will be triggered (default: 0).
|
||||
@ -106,10 +108,10 @@ If readInterval is not specified or set to 0, no further periodic reading will b
|
||||
#### Channel Types
|
||||
|
||||
Standard channels are used most of the time.
|
||||
They are used in the common case where the physical state is owned by a device within the KNX bus, e.g. by a switch actuator who "knows" whether the light is turned on or off, or by a temperature sensor which reports the room temperature regularly.
|
||||
They are used in the common case where the physical state is owned by a device within the KNX bus, e.g., by a switch actuator that "knows" whether the light is turned on or off, or by a temperature sensor that reports the room temperature regularly.
|
||||
|
||||
Control channel types (suffix `-control`) are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could be the case if e.g. a lamp from another binding should be controlled by a KNX wall switch.
|
||||
This could be the case if, for example, a lamp from another binding should be controlled by a KNX wall switch.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type `color`, `color-control`
|
||||
@ -126,10 +128,11 @@ The `hsb` address supports DPT 232.600 (RGB), 242.600 (xyY), and 251.600 (RGBW).
|
||||
Some RGB/RGBW products (e.g. MDT) use HSB values for DPT 232.600 instead of RGB.
|
||||
This is supported as "vendor-specific DPT" with a value of 232.60000.
|
||||
|
||||
RGBW (DPT 251.600) can either be converted to HSBType, or be represented two items: a HSBType for RGB and an additional PercentType for W channel.
|
||||
RGBW (DPT 251.600) can either be converted to HSBType, or represented by two items: a HSBType for RGB and an additional PercentType for the W channel.
|
||||
Default handling for RGBW is to use separate items.
|
||||
Note that this also requires two frames being sent out separately when these elements are sent to the bus, as the binary representation uses a partially populated KNX frame.
|
||||
Alternatively, a single HSB item can be used. Conversion to a single HSBType will loose the exact setting for W, and will reconstruct it when a conversion to RGBW is required.
|
||||
Note that this also requires two frames to be sent out separately when these elements are sent to the bus, as the binary representation uses a partially populated KNX frame.
|
||||
Alternatively, a single HSB item can be used.
|
||||
Conversion to a single HSBType will lose the exact setting for W, and will reconstruct it when a conversion to RGBW is required.
|
||||
This option can be selected using the special DPT 251.60600.
|
||||
|
||||
##### Channel Type `contact`, `contact-control`
|
||||
@ -138,7 +141,7 @@ This option can be selected using the special DPT 251.60600.
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 1.009 |
|
||||
|
||||
*Attention:* Due to a bug in the original implementation, the states for DPT 1.009 are inverted (i.e. `1` is mapped to `OPEN` instead of `CLOSE`).
|
||||
*Attention:* Due to a bug in the original implementation, the states for DPT 1.009 are inverted (i.e., `1` is mapped to `OPEN` instead of `CLOSE`).
|
||||
A change would break all existing installations and is therefore not implemented.
|
||||
|
||||
##### Channel Type `datetime`, `datetime-control`
|
||||
@ -167,10 +170,10 @@ Using the UoM feature of openHAB (QuantityType) requires that the DPT value is s
|
||||
Automatic type conversion will be applied if required.
|
||||
|
||||
Incoming values from the KNX bus are converted to values with units (e.g. `23 °C`).
|
||||
If the channel is linked to the correct item-type (`Number:Temperature` in this case) the display unit can be controlled by item metadata (e.g. `%.1f °F` for 1 digit of precision in Fahrenheit).
|
||||
The unit is stripped if the channel is linked to a plain number item (type `Number`).
|
||||
If the channel is linked to the correct item-type (`Number:Temperature` in this case), the display unit can be controlled by item metadata (e.g., `%.1f °F` for 1 digit of precision in Fahrenheit).
|
||||
The unit is stripped if the channel is linked to a plain number item (type `Number`).
|
||||
|
||||
Outgoing values with unit are first converted to the unit associated with the DPT (e.g. a value of `10 °F` is converted to `-8.33 °C` if the channel has DPT 9.001).
|
||||
Outgoing values with unit are first converted to the unit associated with the DPT (e.g., a value of `10 °F` is converted to `-8.33 °C` if the channel has DPT 9.001).
|
||||
Values from plain number channels are sent as-is (without any conversion).
|
||||
|
||||
##### Channel Type `rollershutter`, `rollershutter-control`
|
||||
@ -196,7 +199,7 @@ Values from plain number channels are sent as-is (without any conversion).
|
||||
#### Control Channel Types
|
||||
|
||||
In contrast to the standard channels above, the control channel types are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could for example be the case if a lamp from another binding should be controlled by a KNX wall switch.
|
||||
This could, for example, be the case if a lamp from another binding should be controlled by a KNX wall switch.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type "switch-control"
|
||||
@ -238,7 +241,7 @@ A change would break all existing installations and is therefore not implemented
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
For UoM support see the explanations of the `number` channel.
|
||||
For UoM support, see the explanations of the `number` channel.
|
||||
|
||||
##### Channel Type "string-control"
|
||||
|
||||
@ -266,16 +269,167 @@ where parts in brackets `[]` denote optional information.
|
||||
This is recommended if you have a dedicated status group address which is added as `listeningGA`.
|
||||
|
||||
The optional `<` sign tells whether the group address of the datapoint accepts read requests on the KNX bus (it does, if the sign is there).
|
||||
The group addresses marked with `<` are read by openHAB during startup.
|
||||
The group addresses marked with `<` are read by openHAB during startup.
|
||||
Future versions might support reading from one GA only.
|
||||
With `*-control` channels, the state is not owned by any device on the KNX bus, therefore no read requests will be sent by the binding, i.e. `<` signs will be ignored for them.
|
||||
|
||||
The element `dpt` is highly recommended and may change to a mandatory element in future versions.
|
||||
If omitted, the corresponding default value will be used (see the channel descriptions above).
|
||||
|
||||
## Mapping DPTs to openHAB Types
|
||||
|
||||
Datapoint Types (DPTs) define how the content of a KNX telegram is interpreted.
|
||||
|
||||
The following table is a complete list of DPTs currently supported by openHAB.
|
||||
OpenHAB supports all DPTs supported by the corresponding release of the Calimero library, plus a few [specific additions](#special-dpts).
|
||||
|
||||
The default mapping is given, however DPTs can be overwritten.
|
||||
KNX frames do not contain information about the encoding or DPT, so any DPT with a compatible byte size and a useful encoding can be used.
|
||||
A good example for this are bitfields represented as String which are mapped to a DPT of DecimalType for handling in rules.
|
||||
For more details, see the KNX specification (section 3.7.2, System Specifications, Interworking, Datapoint Types).
|
||||
|
||||
In case a missing DPT or subtype is needed, there is a good chance that a DPT of matching size and DecimalType is found.
|
||||
Further DPTs and subtypes may be added later once implemented and released in the [Calimero library](https://github.com/calimero-project/calimero-core).
|
||||
|
||||
| DPT | Primary openHAB type (things) (items with UOM) | Remark |
|
||||
|-----------------|----------------------------------------------------|-----------------------------------|
|
||||
| 1.001-1.007 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.008 | UpDownType (e.g. for dimmer, rollershutter) | |
|
||||
| 1.009 | OnOffType (switch), OpenClosedType (contact) | Not according to spec, see above |
|
||||
| 1.010 | StopMoveType (e.g. for rollershutter) | |
|
||||
| 1.011-1.016 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.017 | OnOffType (switch), OpenClosedType (contact) | Trigger, use states OFF or CLOSED |
|
||||
| 1.018-1.019 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.021 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.022 | DecimalType (number) | Counting from 0, use DPT if you need a DecimalType |
|
||||
| 1.023-1.024 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.100 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
| 1.1200-1.1201 | OnOffType (switch), OpenClosedType (contact) | |
|
||||
|||
|
||||
| 2.001-2.012 | DecimalType (number) | |
|
||||
|||
|
||||
| 3.007 | IncreaseDecreaseType (e.g. dimmer) | |
|
||||
| 3.008 | UpDownType (e.g. rollershutter) | |
|
||||
|||
|
||||
| 5.001 | QuantityType\<> (number) (Number:Percent) | Alternatively: PercentType |
|
||||
| 5.003 | QuantityType\<> (number) (Number:Angle) | |
|
||||
| 5.004 | QuantityType\<> (number) (Number:Percent) | 0-255%, no mapping to PercentType |
|
||||
| 5.005 | DecimalType (number) | |
|
||||
| 5.006 | DecimalType (number) | 255 is reserved |
|
||||
| 5.010 | DecimalType (number) | |
|
||||
|||
|
||||
| 6.001 | QuantityType\<> (number) (Number:Percent) | -128..127%, no mapping to PercentType |
|
||||
| 6.010 | DecimalType (number) | -128..127 |
|
||||
| 6.020 | StringType (string) | Override with DPT5.010 if you need DecimalType |
|
||||
|||
|
||||
| 7.001 | DecimalType (number) | |
|
||||
| 7.002-7.007 | QuantityType\<> (number) (Number:Time) | |
|
||||
| 7.010 | DecimalType (number) | |
|
||||
| 7.011 | QuantityType\<> (number) (Number:Length) | |
|
||||
| 7.012 | QuantityType\<> (number) (Number:ElectricCurrent) | |
|
||||
| 7.013 | QuantityType\<> (number) (Number:Length) | |
|
||||
| 7.600 | QuantityType\<> (number) (Number:Temperature) | |
|
||||
|||
|
||||
| 8.001 | DecimalType (number) | |
|
||||
| 8.002-7.007 | QuantityType\<> (number) (Number:Time) | |
|
||||
| 8.010 | QuantityType\<> (number) (Number:Percent) | |
|
||||
| 8.011 | QuantityType\<> (number) (Number:Angle) | |
|
||||
| 8.012 | QuantityType\<> (number) (Number:Length) | |
|
||||
|||
|
||||
| 9.xxx | QuantityType\<> (number) (Number:...) | See [documentation on UOM](https://www.openhab.org/docs/concepts/units-of-measurement.html) |
|
||||
| 9.001 | QuantityType\<> (number) (Number:...) | Lower values than absolute zero will be set to -273 °C |
|
||||
| 9.002-9.003 | QuantityType\<> (number) (Number:...) | |
|
||||
| 9.004-9.008 | QuantityType\<> (number) (Number:...) | No negative values allowed |
|
||||
| 9.009-9.011 | QuantityType\<> (number) (Number:...) | |
|
||||
| 9.020-9.027 | QuantityType\<> (number) (Number:...) | |
|
||||
| 9.027-9.030 | QuantityType\<> (number) (Number:...) | No negative values allowed |
|
||||
|||
|
||||
| 10.001 | DateTimeType (datetime) | Time. Date is set to 1/Jan/1970 + ofs if weekday is given. KNX can represent year 1990..2089. |
|
||||
|||
|
||||
| 11.001 | DateTimeType (datetime) | Date only. |
|
||||
|||
|
||||
| 12.001 | DecimalType (number) | |
|
||||
| 12.100-12.102 | QuantityType\<> (number) (Number:Time) | |
|
||||
| 12.1200-12.1201 | QuantityType\<> (number) (Number:Volume) | |
|
||||
|||
|
||||
| 13.xxx | QuantityType\<> (number) (Number:...) | See [documentation on UOM](https://www.openhab.org/docs/concepts/units-of-measurement.html) |
|
||||
| 13.001 | DecimalType (number) | |
|
||||
| 13.002 | QuantityType\<> (number) (Number:VolumetricFlowRate) | |
|
||||
| 13.010-13.016 | QuantityType\<> (number) (Number:...) | |
|
||||
| 13.100 | QuantityType\<> (number) (Number:...) | |
|
||||
| 13.1200-13.1201 | QuantityType\<> (number) (Number:Time) | |
|
||||
|||
|
||||
| 14.xxx | QuantityType\<> (number) (Number:...) | See [documentation on UOM](https://www.openhab.org/docs/concepts/units-of-measurement.html) |
|
||||
| 14.000-14.080 | QuantityType\<> (number) (Number:...) | |
|
||||
| 14.1200-14.1201 | QuantityType\<> (number) (Number:...) | |
|
||||
|||
|
||||
| 16.000 | StringType (string) | ASCII |
|
||||
| 16.001 | StringType (string) | ISO 8859-1 |
|
||||
|||
|
||||
| 17.001 | DecimalType (number) | Scene 0..63 |
|
||||
|||
|
||||
| 18.001 | DecimalType (number) | Scene 0..63, add offset 0x80 (128) for storing scenes |
|
||||
|||
|
||||
| 19.001 | DateTimeType (datetime) (DateTime) | Date and Time, year can be 1900..2155 |
|
||||
|||
|
||||
| 20.xxx | | Incomplete, only subtypes given below are supported; override with DPT5.010 if you need enum as DecimalType |
|
||||
| 20.001-20.009 | StringType (string) | |
|
||||
| 20.011-20.014 | StringType (string) | |
|
||||
| 20.017 | StringType (string) | |
|
||||
| 20.020-20.021 | StringType (string) | |
|
||||
| 20.100-20.114 | StringType (string) | |
|
||||
| 20.120-20.122 | StringType (string) | |
|
||||
| 20.600-20.610 | StringType (string) | |
|
||||
| 20.801-20.804 | StringType (string) | |
|
||||
| 20.1000-20.1005 | StringType (string) | |
|
||||
| 20.1200 | StringType (string) | |
|
||||
| 20.1202 | StringType (string) | |
|
||||
|||
|
||||
| 21.xxx | | Incomplete, only subtypes given below are supported; override with DPT5.010 if you need bitset as DecimalType |
|
||||
| 21.001-20.002 | StringType (string) | |
|
||||
| 21.100-20.106 | StringType (string) | |
|
||||
| 21.601 | StringType (string) | |
|
||||
| 21.1000-21.1002 | StringType (string) | |
|
||||
| 21.1010 | StringType (string) | |
|
||||
|||
|
||||
| 22.xxx | | Incomplete, only subtypes given below are supported; override with DPT7.010 if you need bitset as DecimalType |
|
||||
| 22.101 | StringType (string) | |
|
||||
| 22.1000 | StringType (string) | |
|
||||
|||
|
||||
| 28.001 | StringType (string) | KNX representation is Null-terminated, do not include null characters |
|
||||
|||
|
||||
| 29.010-29.012 | QuantityType\<> (number) (Number:...) | |
|
||||
|||
|
||||
| 229.001 | DecimalType (number) | Scaling coded in KNX frame is regarded; for sending always encoded with flag "dimensionless" |
|
||||
|||
|
||||
| 232.600 | HSBType (color) | RGB |
|
||||
| 232.60000 | HSBType (color) | Non-Standard, DPT 232.600 with HSB instead of RGB data |
|
||||
|||
|
||||
| 235.001 | QuantityType\<> (number) (Number:ActiveEnergy) | Composed DPT 235.001, first element ActiveEnergy (Wh), read only |
|
||||
| 235.61001 | DecimalType (number) | Non-Standard, composed DPT 235.001, second element Tariff (plain number), read only |
|
||||
|||
|
||||
| 242.600 | HSBType (color) | xyY |
|
||||
|||
|
||||
| 243.600 | StringType (string) | |
|
||||
|||
|
||||
| 249.600 | StringType (string) | |
|
||||
|||
|
||||
| 250.600 | StringType (string) | |
|
||||
|||
|
||||
| 251.600 | HSBType (color) | RGBW, RGB part as HSBType |
|
||||
| 251.600 | PercentType | RGBW, W part separately for Dimmer |
|
||||
| 251.60600 | HSBType (color) | Non-Standard, lossy conversion from HSBType to RGBW |
|
||||
|||
|
||||
| 252.600 | StringType (string) | |
|
||||
|||
|
||||
| 253.600 | StringType (string) | |
|
||||
|||
|
||||
| 254.600 | StringType (string) | |
|
||||
|||
|
||||
|
||||
## Special DPTs
|
||||
|
||||
OpenHAB supports all DPTs supported by the corresponding release of Calimero library.
|
||||
OpenHAB supports all DPTs supported by the corresponding release of the Calimero library.
|
||||
|
||||
Additional DPTs have been introduced to add functionality:
|
||||
|
||||
@ -292,9 +446,9 @@ Additional DPTs have been introduced to add functionality:
|
||||
### KNX IP Secure
|
||||
|
||||
KNX IP Secure protects the traffic between openHAB and your KNX installation.
|
||||
It **requires a KNX Secure Router or a Secure IP Interface** and a KNX installation **with security features enabled in ETS tool**.
|
||||
It **requires a KNX Secure Router or a Secure IP Interface** and a KNX installation **with security features enabled in the ETS tool**.
|
||||
|
||||
For _Secure routing_ mode, the so called `backbone key` needs to be configured in openHAB.
|
||||
For _Secure routing_ mode, the so-called `backbone key` needs to be configured in openHAB.
|
||||
It is created by the ETS tool and cannot be changed via the ETS user interface.
|
||||
|
||||
- The backbone key can be extracted from Security report (ETS, Reports, Security, look for a 32-digit key) and specified in parameter `routerBackboneKey`.
|
||||
@ -302,12 +456,16 @@ It is created by the ETS tool and cannot be changed via the ETS user interface.
|
||||
For _Secure tunneling_ with a Secure IP Interface (or a router in tunneling mode), more parameters are required.
|
||||
A unique device authentication key, and a specific tunnel identifier and password need to be available.
|
||||
|
||||
- All information can be looked up in ETS and provided separately: `tunnelDeviceAuthentication`, `tunnelUserPassword`. `tunnelUserId` is a number which is not directly visible in ETS, but can be looked up in keyring export or deduced (typically 2 for the first tunnel of a device, 3 for the second one, ...). `tunnelUserPasswort` is set in ETS in the properties of the tunnel (below the IP interface you will see the different tunnels listed) denoted as "Password". `tunnelDeviceAuthentication` is set in the properties of the IP interface itself, check for a tab "IP" and a description "Authentication Code".
|
||||
- All information can be looked up in ETS and provided separately: `tunnelDeviceAuthentication`, `tunnelUserPassword`.
|
||||
`tunnelUserId` is a number that is not directly visible in ETS, but can be looked up in keyring export or deduced (typically 2 for the first tunnel of a device, 3 for the second one, ...).
|
||||
`tunnelUserPasswort` is set in ETS in the properties of the tunnel (below the IP interface, you will see the different tunnels listed) and denoted as "Password".
|
||||
`tunnelDeviceAuthentication` is set in the properties of the IP interface itself; check for the tab "IP" and the description "Authentication Code".
|
||||
|
||||
### KNX Data Secure
|
||||
|
||||
KNX Data Secure protects the content of messages on the KNX bus. In a KNX installation, both classic and secure group addresses can coexist.
|
||||
Data Secure does _not_ necessarily require a KNX Secure Router or a Secure IP Interface, but a KNX installation with newer KNX devices which support Data Secure and with **security features enabled in ETS tool**.
|
||||
KNX Data Secure protects the content of messages on the KNX bus.
|
||||
In a KNX installation, both classic and secure group addresses can coexist.
|
||||
Data Secure does _not_ necessarily require a KNX Secure Router or a Secure IP Interface, but a KNX installation with newer KNX devices that support Data Secure and with **security features enabled in the ETS tool**.
|
||||
|
||||
> NOTE: **openHAB currently ignores messages with secure group addresses.**
|
||||
|
||||
|