[lcn] Fix setting of variables (#13690)
Signed-off-by: Fabian Wolter <github@fabian-wolter.de>
This commit is contained in:
parent
49fa349590
commit
3ed44f1ba5
@ -140,7 +140,7 @@ If a special command is needed, the [Hit Key](#hit-key) action (German: "Sende T
|
||||
| Motor/Shutter on Dimmer Outputs | Motor/Rollladen an Ausgängen | rollershutteroutput | 1-4 | Rollershutter | Control roller shutters on dimmer outputs |
|
||||
| Motor/Shutter on Relays | Motor/Rollladen an Relais | rollershutterrelay | 1-4 | Rollershutter, Dimmer | Control position of roller shutters on relays (Supports UpDown, StopMove, Percent) |
|
||||
| Shutter Slat Angle on Relays | Rollladenlamellen an Relais | rollershutterrelayslat | 1-4 | Rollershutter, Dimmer | Control slat angle of roller shutters on relays (Supports UpDown, StopMove, Percent) |
|
||||
| Variables | Variable anzeigen | variable | 1-12 | Number | Sets and visualizes the value of a variable. |
|
||||
| Variables | Variable anzeigen | variable | 1-12 | Number | Sets and visualizes the value of a variable. See note. |
|
||||
| Regulator Set Setpoint | Regler Sollwert ändern | rvarsetpoint | 1-2 | Number | Sets and visualizes the setpoint of a regulator. |
|
||||
| Regulator Set Mode | Reglerverhalten ändern | rvarmode | 1-2 | String | Sets the mode of the regulator: `HEATING` or `COOLING` |
|
||||
| Regulator Lock | Regler sperren | rvarlock | 1-2 | Switch | Locks a regulator and visualizes its locking state. |
|
||||
@ -194,13 +194,13 @@ If a special command is needed, the [Hit Key](#hit-key) action (German: "Sende T
|
||||
| Set S0 Counters | S0-Zähler setzen | - | - | - | Not implemented |
|
||||
| Status Command | Statuskommandos | - | - | - | Not implemented |
|
||||
|
||||
**For some *Channel*s a unit should be configured for visualization.** By default the native LCN value is used.
|
||||
*Notes:*
|
||||
|
||||
S0 counter Channels need to be the pulses per kWh configured. If the value is left blank, a default value of 1000 pulses/kWh is set.
|
||||
|
||||
The Rollershutter Channels provide the boolean parameter `invertUpDown`, which can be set to 'true' if the Up/Down wires are interchanged.
|
||||
|
||||
The binary sensor Channels provide the boolean parameter `invertState`, which can be set to 'true' if the binary sensor connected uses inverted logic for signaling open/closed.
|
||||
- **For some *Channel*s (e.g. temperature) a unit should be configured in the channel configuration.** By default the native LCN value is used.
|
||||
- S0 counter Channels need to be the pulses per kWh configured. If the value is left blank, a default value of 1000 pulses/kWh is set.
|
||||
- When setting a variable via openHAB, the variable must be configured as counter in LCN-PRO. The variable must be set initially by the module after power up.
|
||||
- The Rollershutter Channels provide the boolean parameter `invertUpDown`, which can be set to 'true' if the Up/Down wires are interchanged.
|
||||
- The binary sensor Channels provide the boolean parameter `invertState`, which can be set to 'true' if the binary sensor connected uses inverted logic for signaling open/closed.
|
||||
|
||||
### Transponder/Fingerprints
|
||||
|
||||
|
@ -513,13 +513,13 @@ public final class PckGenerator {
|
||||
case UNKNOWN:
|
||||
throw new LcnException("Variable unknown");
|
||||
case VARIABLE:
|
||||
return String.format("MWT%03d", id + 1);
|
||||
return "MWT" + (id + 1);
|
||||
case REGULATOR:
|
||||
return String.format("MWS%03d", id + 1);
|
||||
return "MWS" + (id + 1);
|
||||
case THRESHOLD:
|
||||
return String.format("SE%03d", id + 1); // Whole register
|
||||
return "SE" + (id + 1); // Whole register
|
||||
case S0INPUT:
|
||||
return String.format("MWC%03d", id + 1);
|
||||
return "MWC" + (id + 1);
|
||||
}
|
||||
throw new LcnException("Unsupported variable type: " + variable);
|
||||