Update README.md (#16309)

update on the units. Measured with CMI, Firmware version 1.38.3

Signed-off-by: Michael Roeder <16511595+roednix@users.noreply.github.com>
This commit is contained in:
Michael Roeder 2024-01-22 23:15:14 +01:00 committed by GitHub
parent e62bcf5db4
commit 3d1c6baf49
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

View File

@ -192,17 +192,26 @@ The binding supports all 21 measure types that exist according to the TA documen
Unfortunately, the documentation is not consistent here, so most of the types are supported only by generic names.
The known measure types are:
| id | type | description |
|--------|---------------|-----------------------------------------------|
| 1 | Temperature | Tempeature value. Value is multiplied by 0.1 |
| 2 | Unknown2 | |
| 3 | Unknown3 | |
| 4 | Seconds | |
| 5...9 | Unknown5..9 | |
| 10 | Kilowatt | |
| 11 | Kilowatthours | |
| 12 | Megawatthours | |
| 13..21 | Unknown | |
| id | type | unit | description |
|--------|---------------|---------|----------------------------------------------|
| 1 | Temperature | °C | Temperature value, multiplied by 0.1 |
| 2 | Energy Flux | W/m2 | e.g. for solar irridiation |
| 3 | Flow Rate | l/h | e.g. for flow meters such as TA FTS-xx |
| 4 | Time | s | |
| 5 | Time | min | |
| 6 | Flow Rate | l/lmp | standardized lpm flowrate |
| 7 | Temperature | K | Kelvin, e.g. for Temperature differences |
| 8 | Percentage | % | |
| 9 | unknown | : | might be another dimensionless unit |
| 10 | Power | kW | |
| 11 | Energy | KWh | |
| 12 | Energy | MWh | |
| 13 | el Voltage | V | |
| 14 | el. Current | mA | |
| 15 | Time | hours | |
| 16 | dimensionless | [none] | use for multiplexers, etc |
| 17.. | repeating again from 1, e.g 17==1, 18==2, ... |
## Full Example