[enocean] Spell when devices support power measurement, power failure detection (#17522)

configurable dimming or pilot wire, do not have local control.

Co-authored-by: Cody Cutrer <cody@cutrer.us>
This commit is contained in:
Дилян Палаузов 2024-10-13 22:18:26 +03:00 committed by GitHub
parent 66bcd4ef9e
commit 39a2754dc6
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
2 changed files with 40 additions and 40 deletions

View File

@ -184,18 +184,18 @@ thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_00 = Swi
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_01 = Switching (EEP: D2_01_01)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_02 = Switching, dimming and energy measurement (EEP: D2_01_02)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_03 = Switching and dimming (EEP: D2_01_03)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_04 = Switching, dimming and energy measurement (EEP: D2_01_04)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_05 = Switching, dimming and energy measurement (EEP: D2_01_05)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_06 = Switching and energy measurement (EEP: D2_01_06)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_07 = Switching (EEP: D2_01_07)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_08 = Switching, dimming and energy measurement (EEP: D2_01_08)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_09 = Switching, dimming and energy measurement (EEP: D2_01_09)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_04 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_04)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_05 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_05)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_06 = Switching and energy measurement without local control (EEP: D2_01_06)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_07 = Switching without local control (EEP: D2_01_07)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_08 = Switching, power and energy measurement (EEP: D2_01_08)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_09 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_09)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_09_PERMUNDO = Permundo PSC
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0A = Switching and energy measurement (EEP: D2_01_0A)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0B = Switching and energy measurement (EEP: D2_01_0B)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0C = Switching and energy measurement (EEP: D2_01_0C)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0A = Switching and power failure detection (EEP: D2_01_0A)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0B = Switching, power failure detection, power and energy measurement (EEP: D2_01_0B)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0C = Switching, pilot wire mode, power and energy measurement (EEP: D2_01_0C)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0D = Switching (EEP: D2_01_0D)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0E = Switching and energy measurement (EEP: D2_01_0E)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0E = Switching, power and energy measurement (EEP: D2_01_0E)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0F = Switching (EEP: D2_01_0F)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_0F_NODON = NodON SIN-2-1-00 (EEP: D2_01_0F)
thing-type.config.enocean.measurementSwitch.receivingEEPId.option.D2_01_11 = Switching (EEP: D2_01_11)
@ -209,18 +209,18 @@ thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_00 = Switc
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_01 = Switching (EEP: D2_01_01)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_02 = Switching, dimming and energy measurement (EEP: D2_01_02)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_03 = Switching and dimming (EEP: D2_01_03)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_04 = Switching, dimming and energy measurement (EEP: D2_01_04)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_05 = Switching, dimming and energy measurement (EEP: D2_01_05)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_06 = Switching and energy measurement (EEP: D2_01_06)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_07 = Switching (EEP: D2_01_07)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_08 = Switching, dimming and energy measurement (EEP: D2_01_08)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_09 = Switching, dimming and energy measurement (EEP: D2_01_09)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_04 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_04)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_05 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_05)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_06 = Switching and energy measurement without local control (EEP: D2_01_06)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_07 = Switching without local control (EEP: D2_01_07)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_08 = Switching, power and energy measurement (EEP: D2_01_08)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_09 = Switching, configurable dimming, power and energy measurement (EEP: D2_01_09)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_09_PERMUNDO = Permundo PSC
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0A = Switching and energy measurement (EEP: D2_01_0A)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0B = Switching and energy measurement (EEP: D2_01_0B)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0C = Switching and energy measurement (EEP: D2_01_0C)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0A = Switching and power failure detection (EEP: D2_01_0A)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0B = Switching, power failure detection, power and energy measurement (EEP: D2_01_0B)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0C = Switching, pilot wire mode, power and energy measurement (EEP: D2_01_0C)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0D = Switching (EEP: D2_01_0D)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0E = Switching and energy measurement (EEP: D2_01_0E)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0E = Switching, power and energy measurement (EEP: D2_01_0E)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0F = Switching (EEP: D2_01_0F)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_0F_NODON = NodON SIN-2-1-00 (EEP: D2_01_0F)
thing-type.config.enocean.measurementSwitch.sendingEEPId.option.D2_01_11 = Switching (EEP: D2_01_11)

View File

@ -34,18 +34,18 @@
<option value="D2_01_01">Switching (EEP: D2_01_01)</option>
<option value="D2_01_02">Switching, dimming and energy measurement (EEP: D2_01_02)</option>
<option value="D2_01_03">Switching and dimming (EEP: D2_01_03)</option>
<option value="D2_01_04">Switching, dimming and energy measurement (EEP: D2_01_04)</option>
<option value="D2_01_05">Switching, dimming and energy measurement (EEP: D2_01_05)</option>
<option value="D2_01_06">Switching and energy measurement (EEP: D2_01_06)</option>
<option value="D2_01_07">Switching (EEP: D2_01_07)</option>
<option value="D2_01_08">Switching, dimming and energy measurement (EEP: D2_01_08)</option>
<option value="D2_01_09">Switching, dimming and energy measurement (EEP: D2_01_09)</option>
<option value="D2_01_04">Switching, configurable dimming, power and energy measurement (EEP: D2_01_04)</option>
<option value="D2_01_05">Switching, configurable dimming, power and energy measurement (EEP: D2_01_05)</option>
<option value="D2_01_06">Switching and energy measurement without local control (EEP: D2_01_06)</option>
<option value="D2_01_07">Switching without local control (EEP: D2_01_07)</option>
<option value="D2_01_08">Switching, power and energy measurement (EEP: D2_01_08)</option>
<option value="D2_01_09">Switching, configurable dimming, power and energy measurement (EEP: D2_01_09)</option>
<option value="D2_01_09_PERMUNDO">Permundo PSC</option>
<option value="D2_01_0A">Switching and energy measurement (EEP: D2_01_0A)</option>
<option value="D2_01_0B">Switching and energy measurement (EEP: D2_01_0B)</option>
<option value="D2_01_0C">Switching and energy measurement (EEP: D2_01_0C)</option>
<option value="D2_01_0A">Switching and power failure detection (EEP: D2_01_0A)</option>
<option value="D2_01_0B">Switching, power failure detection, power and energy measurement (EEP: D2_01_0B)</option>
<option value="D2_01_0C">Switching, pilot wire mode, power and energy measurement (EEP: D2_01_0C)</option>
<option value="D2_01_0D">Switching (EEP: D2_01_0D)</option>
<option value="D2_01_0E">Switching and energy measurement (EEP: D2_01_0E)</option>
<option value="D2_01_0E">Switching, power and energy measurement (EEP: D2_01_0E)</option>
<option value="D2_01_0F">Switching (EEP: D2_01_0F)</option>
<option value="D2_01_0F_NODON">NodON SIN-2-1-00 (EEP: D2_01_0F)</option>
<option value="D2_01_11">Switching (EEP: D2_01_11)</option>
@ -65,18 +65,18 @@
<option value="D2_01_01">Switching (EEP: D2_01_01)</option>
<option value="D2_01_02">Switching, dimming and energy measurement (EEP: D2_01_02)</option>
<option value="D2_01_03">Switching and dimming (EEP: D2_01_03)</option>
<option value="D2_01_04">Switching, dimming and energy measurement (EEP: D2_01_04)</option>
<option value="D2_01_05">Switching, dimming and energy measurement (EEP: D2_01_05)</option>
<option value="D2_01_06">Switching and energy measurement (EEP: D2_01_06)</option>
<option value="D2_01_07">Switching (EEP: D2_01_07)</option>
<option value="D2_01_08">Switching, dimming and energy measurement (EEP: D2_01_08)</option>
<option value="D2_01_09">Switching, dimming and energy measurement (EEP: D2_01_09)</option>
<option value="D2_01_04">Switching, configurable dimming, power and energy measurement (EEP: D2_01_04)</option>
<option value="D2_01_05">Switching, configurable dimming, power and energy measurement (EEP: D2_01_05)</option>
<option value="D2_01_06">Switching and energy measurement without local control (EEP: D2_01_06)</option>
<option value="D2_01_07">Switching without local control (EEP: D2_01_07)</option>
<option value="D2_01_08">Switching, power and energy measurement (EEP: D2_01_08)</option>
<option value="D2_01_09">Switching, configurable dimming, power and energy measurement (EEP: D2_01_09)</option>
<option value="D2_01_09_PERMUNDO">Permundo PSC</option>
<option value="D2_01_0A">Switching and energy measurement (EEP: D2_01_0A)</option>
<option value="D2_01_0B">Switching and energy measurement (EEP: D2_01_0B)</option>
<option value="D2_01_0C">Switching and energy measurement (EEP: D2_01_0C)</option>
<option value="D2_01_0A">Switching and power failure detection (EEP: D2_01_0A)</option>
<option value="D2_01_0B">Switching, power failure detection, power and energy measurement (EEP: D2_01_0B)</option>
<option value="D2_01_0C">Switching, pilot wire mode, power and energy measurement (EEP: D2_01_0C)</option>
<option value="D2_01_0D">Switching (EEP: D2_01_0D)</option>
<option value="D2_01_0E">Switching and energy measurement (EEP: D2_01_0E)</option>
<option value="D2_01_0E">Switching, power and energy measurement (EEP: D2_01_0E)</option>
<option value="D2_01_0F">Switching (EEP: D2_01_0F)</option>
<option value="D2_01_0F_NODON">NodON SIN-2-1-00 (EEP: D2_01_0F)</option>
<option value="D2_01_11">Switching (EEP: D2_01_11)</option>