mirror of
https://github.com/openhab/openhab-addons.git
synced 2025-01-10 07:02:02 +01:00
[enocean] Fix discovery of D2-50 devices (#10577)
This change accepts a new message type which is sent by some air ventilation devices durin teach in. This is required for the search feature to detect these devices correctly. Signed-off-by: David Schumann <david@dev-core.org>
This commit is contained in:
parent
e6d8dfb7e1
commit
2bb7c62dec
@ -44,6 +44,7 @@ public class D2_50 extends _VLDMessage {
|
||||
protected static final byte MT_CONTROL = 0x20;
|
||||
protected static final byte MT_BASIC_STATUS = 0x40;
|
||||
protected static final byte MT_EXTENDED_STATUS = 0x60; // not yet implemented
|
||||
protected static final byte MT_UNKNOWN_STATUS = (byte) 0x80; // Sent by some systems during teach in
|
||||
|
||||
protected static final byte rmtMask = (byte) 0x0f;
|
||||
protected static final byte RMT_BASIC_STATUS = 0x00;
|
||||
@ -177,7 +178,10 @@ public class D2_50 extends _VLDMessage {
|
||||
return bytes.length == 14;
|
||||
case MT_EXTENDED_STATUS: // MT_EXTENDED_STATUS is not yet supported, however return true to avoid Exceptions
|
||||
return true;
|
||||
case MT_UNKNOWN_STATUS:
|
||||
return true;
|
||||
default:
|
||||
logger.error("Invalid data, unknown message type: {} ({})", getMessageType(bytes[0]), bytes);
|
||||
return false;
|
||||
}
|
||||
}
|
||||
|