2020-09-21 01:58:32 +02:00
|
|
|
# SMA Energy Meter Binding
|
|
|
|
|
|
|
|
This Binding is used to display the measured values of a SMA Energy Meter device.
|
|
|
|
It shows purchased and grid feed-in power and energy.
|
|
|
|
|
|
|
|
## Supported Things
|
|
|
|
|
|
|
|
This Binding supports SMA Energy Meter devices.
|
|
|
|
|
|
|
|
## Discovery
|
|
|
|
|
|
|
|
The Energy Meter is discovered by receiving data on the default multicast IP address.
|
|
|
|
|
|
|
|
## Binding Configuration
|
|
|
|
|
|
|
|
No binding configuration required.
|
|
|
|
|
|
|
|
## Thing Configuration
|
|
|
|
|
|
|
|
Usually no manual configuration is required, as the multicast IP address and the port remain on their factory set values.
|
|
|
|
Optionally, a refresh interval (in seconds) can be defined.
|
|
|
|
|
2024-06-25 21:27:43 +02:00
|
|
|
| Parameter | Name | Description | Required | Default |
|
|
|
|
|------------------|-----------------|------------------------------------------------------------|----------|-----------------|
|
|
|
|
| `serialNumber` | Serial number | Serial number of a meter. | yes | |
|
|
|
|
| `mcastGroup` | Multicast Group | Multicast group used by meter. | yes | 239.12.255.254 |
|
|
|
|
| `port` | Port | Port number used by meter. | no | 9522 |
|
|
|
|
| `pollingPeriod` | Polling Period | Polling period used to publish meter reading (in seconds). | no | 30 |
|
2024-05-10 17:25:48 +02:00
|
|
|
|
|
|
|
The polling period parameter is used to trigger readout of meter. In case if two consecutive readout attempts fail thing will report offline status.
|
|
|
|
|
2020-09-21 01:58:32 +02:00
|
|
|
## Channels
|
|
|
|
|
|
|
|
| Channel | Description |
|
|
|
|
|-------------|------------------------|
|
|
|
|
| powerIn | Purchased power |
|
2024-10-21 17:45:33 +02:00
|
|
|
| powerInL1 | Purchased power L1 |
|
2020-09-21 01:58:32 +02:00
|
|
|
| powerInL2 | Purchased power L2 |
|
|
|
|
| powerInL3 | Purchased power L3 |
|
|
|
|
| powerOut | Grid feed-in power |
|
|
|
|
| powerOutL1 | Grid feed-in power L1 |
|
|
|
|
| powerOutL2 | Grid feed-in power L2 |
|
|
|
|
| powerOutL3 | Grid feed-in power L3 |
|
|
|
|
| energyIn | Purchased energy |
|
|
|
|
| energyInL1 | Purchased energy L1 |
|
|
|
|
| energyInL2 | Purchased energy L2 |
|
|
|
|
| energyInL3 | Purchased energy L3 |
|
|
|
|
| energyOut | Grid feed-in energy |
|
|
|
|
| energyOutL1 | Grid feed-in energy L1 |
|
|
|
|
| energyOutL2 | Grid feed-in energy L2 |
|
|
|
|
| energyOutL3 | Grid feed-in energy L3 |
|
|
|
|
|
|
|
|
## Full example
|
|
|
|
|
|
|
|
N/A
|