2020-09-21 01:58:32 +02:00
# Autelis Pool Control Binding
Autelis manufactures a network enabled pool interface for many popular pool systems.
2021-04-24 20:39:51 +02:00
See [the Autelis website ](https://www.autelis.com ) and the [Autelis Command Protocol ](https://www.autelis.com/wiki/index.php?title=Pool_Control_(PI )_HTTP_Command_Reference) for more information.
2020-09-21 01:58:32 +02:00
This binding supports:
2022-12-07 21:09:32 +01:00
- Jandy and Pentair models
- Read circuit, auxiliary, temperature, pump, chemistry and system values
- Control circuit, auxiliary lighting scenes, and temperature set points
2020-09-21 01:58:32 +02:00
## Auto Discovery
The binding will automatically discover Autelis controllers using UPnP.
If found it will try and connect with the factory default username and password.
## Binding Configuration
The binding requires no special configuration
## Manual Thing Configuration
The Autelis binding requires the host, port, username and password
In the thing file, this looks e.g. like
2022-12-07 21:09:32 +01:00
```java
2020-09-21 01:58:32 +02:00
Thing autelis:pentair:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]
```
or
2022-12-07 21:09:32 +01:00
```java
2020-09-21 01:58:32 +02:00
Thing autelis:jandy:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]
```
## Channels
### Pentair
Pentair devices support the following channels:
| Channel Type ID | Item Type |
|---------------------|-----------|
| system-runstate | Number |
| system-model | Number |
| system-haddr | Number |
| system-opmode | Number |
| system-freeze | Number |
| system-sensor1 | Number |
| system-sensor2 | Number |
| system-sensor3 | Number |
| system-sensor4 | Number |
| system-sensor5 | Number |
| system-version | String |
| system-time | Number |
| equipment-circuit1 | Switch |
| equipment-circuit2 | Switch |
| equipment-circuit3 | Switch |
| equipment-circuit4 | Switch |
| equipment-circuit5 | Switch |
| equipment-circuit6 | Switch |
| equipment-circuit7 | Switch |
| equipment-circuit8 | Switch |
| equipment-circuit9 | Switch |
| equipment-circuit10 | Switch |
| equipment-feature1 | Number |
| equipment-feature2 | Number |
| equipment-feature3 | Number |
| equipment-feature4 | Number |
| equipment-feature5 | Number |
| equipment-feature6 | Number |
| equipment-feature7 | Number |
| equipment-feature8 | Number |
| equipment-feature9 | Number |
| equipment-feature10 | Number |
| temp-poolht | Number |
| temp-spaht | Number |
| temp-htstatus | Number |
| temp-poolsp | Number |
| temp-spasp | Number |
| temp-pooltemp | Number |
| temp-spatemp | Number |
| temp-airtemp | Number |
| temp-soltemp | Number |
| temp-tempunits | String |
| temp-htpump | Number |
| pump-pump1 | String |
| pump-pump2 | String |
| pump-pump3 | String |
| pump-pump4 | String |
| pump-pump5 | String |
| pump-pump6 | String |
| pump-pump7 | String |
| pump-pump8 | String |
| chlor-chloren | Number |
| chlor-poolsp | Number |
| chlor-spasp | Number |
| chlor-salt | Number |
| chlor-super | Number |
| chlor-chlorerr | Number |
| chlor-chlorname | String |
| lightscmd | String |
| reboot | Switch |
### Jandy
Jandy devices support the following channels:
| Channel Type ID | Item Type |
|---------------------|-----------|
| system-model | Number |
| system-dip | Number |
| system-opmode | Number |
| system-vbat | Number |
| system-lowbat | Number |
| system-time | Number |
| equipment-pump | Number |
| equipment-pumplo | Number |
| equipment-spa | Number |
| equipment-waterfall | Number |
| equipment-cleaner | Number |
| equipment-poolht | Number |
| equipment-poolht2 | Number |
| equipment-spaht | Number |
| equipment-solarht | Number |
| equipment-htpmp | Number |
| equipment-aux1 | Number |
| equipment-aux2 | Number |
| equipment-aux3 | Number |
| equipment-aux4 | Number |
| equipment-aux5 | Number |
| equipment-aux6 | Number |
| equipment-aux7 | Number |
| equipment-aux8 | Number |
| equipment-aux9 | Number |
| equipment-aux10 | Number |
| equipment-aux11 | Number |
| equipment-aux12 | Number |
| equipment-aux13 | Number |
| equipment-aux14 | Number |
| equipment-aux15 | Number |
| temp-poolsp | Number |
| temp-poolsp2 | Number |
| temp-pooltemp | Number |
| temp-spatemp | Number |
| temp-airtemp | Number |
| temp-solartemp | Number |
| temp-tempunits | String |
| pump-vsp1 | String |
| pump-vsp2 | String |
| pump-vsp3 | String |
| pump-vsp4 | String |
| chem-avail | Number |
| chem-chlrp | Number |
| chem-saltp | Number |
| chem-chlrs | Number |
| chem-slats | Number |
| chem-orp1 | Number |
| chem-orp2 | Number |
| chem-ph1 | Number |
| chem-ph2 | Number |
| chem-orpfd1 | Number |
| chem-orpfd2 | Number |
| chem-phfd1 | Number |
| chem-phfd2 | Number |