2020-09-21 01:58:32 +02:00
# Omnik Inverter Binding
This binding reads metrics from Omnik Solar Inverters.
## Supported Things
All Omniksols are expected to function, provided they have the Wifi module. At
moment of writing the _Omniksol-3.0k-TL2_ has been tested.
## Discovery
No autodiscovery available
## Thing Configuration
| Config | Description | type | Default |
| :------- | :------------ | :----- | :-------- |
| hostname | The hostname or ip through which the inverter can be accessed | string | n/a |
| port | TCP port through which the inverter listens on for incoming connections | integer | 8899 |
| serial | The serial of the wifi module. The Wifi module's SSID contains the number. This is the numerical part only, i.e. without _AP__ | integer | n/a |
## Channels
2021-12-15 09:20:21 +01:00
| Channel Type Id | Item Type | Description |
|:---------------|:--------------|:------------------------------------------------------------------------------------------------------------------|
| power | Number:Power | The instantaneous power generation for feed 1 to the grid, in Watt by default (**deprecated**; same as powerAC1) |
| powerAC1 | Number:Power | The instantaneous power generation for feed 1 to the grid, in Watt by default |
| powerAC2 | Number:Power | The instantaneous power generation for feed 2 to the grid, in Watt by default |
| powerAC3 | Number:Power | The instantaneous power generation for feed 3 to the grid, in Watt by default |
| currentPV1 | Number:Current | The current generation for input string 1, in ampere by default |
| currentPV2 | Number:Current | The current generation for input string 2, in ampere by default |
| currentPV3 | Number:Current | The current generation for input string 3, in ampere by default |
| voltagePV1 | Number:Voltage | The voltage on input string 1, in volt by default |
| voltagePV2 | Number:Voltage | The voltage on input string 2, in volt by default |
| voltagePV3 | Number:Voltage | The voltage on input string 3, in volt by default |
| energyToday | Number:Energy | The amount of energy generated today, in kWh by default |
| energyTotal | Number:Energy | The total amount of energy generated, in kWh by default |
2020-09-21 01:58:32 +02:00
## Full Example
### demo.things
```
Thing omnikinverter:omnik:70ecb4f0 "Solar Inverter" [ hostname="igen-wifi.lan",serial=604455290]
```
### demo.items
```
2021-12-15 09:20:21 +01:00
Number:Power OmnikInverterBindingThing_InstantaneousPower "Solar Power" < sun > {channel="omnikinverter:omnik:70ecb4f0:power"}
Number:Power OmnikInverterBindingThing_InstantaneousPower1 "Solar Power 1" < sun > {channel="omnikinverter:omnik:70ecb4f0:powerAC1"}
Number:Power OmnikInverterBindingThing_InstantaneousPower2 "Solar Power 2" < sun > {channel="omnikinverter:omnik:70ecb4f0:powerAC2"}
Number:Power OmnikInverterBindingThing_InstantaneousPower3 "Solar Power 3" < sun > {channel="omnikinverter:omnik:70ecb4f0:powerAC3"}
Number:Voltage OmnikInverterBindingThing_VoltagePV1 "PV Voltage 1" {channel="omnikinverter:omnik:70ecb4f0:voltagePV1"}
Number:Voltage OmnikInverterBindingThing_VoltagePV2 "PV Voltage 2" {channel="omnikinverter:omnik:70ecb4f0:voltagePV2"}
Number:Voltage OmnikInverterBindingThing_VoltagePV3 "PV Voltage 3" {channel="omnikinverter:omnik:70ecb4f0:voltagePV3"}
Number:Current OmnikInverterBindingThing_CurrentPV1 "PV current 1" {channel="omnikinverter:omnik:70ecb4f0:currentPV1"}
Number:Current OmnikInverterBindingThing_CurrentPV2 "PV current 2" {channel="omnikinverter:omnik:70ecb4f0:currentPV2"}
Number:Current OmnikInverterBindingThing_CurrentPV3 "PV current 3" {channel="omnikinverter:omnik:70ecb4f0:currentPV3"}
Number:Energy OmnikInverterBindingThing_TotalGeneratedEnergyToday "Solar Energy Today" < sun > {channel="omnikinverter:omnik:70ecb4f0:energyToday"}
Number:Energy OmnikInverterBindingThing_TotalGeneratedEnergy "Solar Energy Total" {channel="omnikinverter:omnik:70ecb4f0:energyTotal"}
2020-09-21 01:58:32 +02:00
```
### Sitemap
```
Text item=OmnikInverterBindingThing_InstantaneousPower
2021-12-15 09:20:21 +01:00
Text item=OmnikInverterBindingThing_InstantaneousPower1
Text item=OmnikInverterBindingThing_InstantaneousPower2
Text item=OmnikInverterBindingThing_InstantaneousPower3
Text item=OmnikInverterBindingThing_VoltagePV1
Text item=OmnikInverterBindingThing_VoltagePV2
Text item=OmnikInverterBindingThing_VoltagePV3
Text item=OmnikInverterBindingThing_CurrentPV1
Text item=OmnikInverterBindingThing_CurrentPV2
Text item=OmnikInverterBindingThing_CurrentPV3
Text item=OmnikInverterBindingThing_TotalGeneratedEnergyToday
Text item=OmnikInverterBindingThing_TotalGeneratedEnergy
2020-09-21 01:58:32 +02:00
```
## References
Based on the work of https://github.com/Woutrrr/Omnik-Data-Logger