# Konnected Binding
|
||
|
|
||
|
This binding is for interacting with the [Konnected Alarm Panel](https://konnected.io/).
|
||
|
A module which interfaces with existing home security sensors.
|
||
|
Konnected is an open-source firmware and software that runs on a NodeMCU ESP8266 device.
|
||
|
The Konnected hardware is specifically designed for an alarm panel installation, but the general purpose firmware/software can be run on any ESP8266 device.
|
||
|
|
||
|
## Supported Things
|
||
|
|
||
|
This binding supports one type of thing module, which represents a Konnected Alarm Panel.
|
||
|
|
||
|
## Discovery
|
||
|
|
||
|
The binding will auto discover The Konnected Alarm Panels which are attached to the same network as the server running openHAB via UPnP.
|
||
|
The binding will then create things for each module discovered which can be added.
|
||
|
|
||
|
## Thing Configuration
|
||
|
|
||
|
The binding attempts to discover The Konnected Alarm Panels via the UPnP service.
|
||
|
The auto-discovery service of the binding will detect the ip address and port of the Konnected Alarm Panel.
|
||
|
The binding will attempt to obtain the ip address of your openHAB server as configured in the OSGi framework.
|
||
|
However, if it is unable to determine the ip address it will also attempt to use the network address service to obtain the ip address and port.
|
||
|
In addition you can also turn off discovery which when this setting is synced to the module will cause the device to no longer respond to UPnP requests as documented.
|
||
|
https://help.konnected.io/support/solutions/articles/32000023968-disabling-device-discovery
|
||
|
Please use this setting with caution and do not disable until a static ip address has been provided for your Konnected Alarm Panel via DHCP, router or otherwise.
|
||
|
The blink setting will disable the transmission LED on the Konnected Alarm Panel.
|
||
|
|
||
|
|
||
|
## Channels
|
||
|
|
||
|
The auto discovered thing adds two default channels.
|
||
|
|
||
|
| Channel | Channel Id | Channel Type | Description |
|
||
|
|---------|------------|--------------|----------------------------------------------------------|
|
||
|
| 1 | Zone_6 | Switch | A Switch channel for zone 6 |
|
||
|
| 2 | Out | Actuator | The Channel for the Out Pin on the Konnected Alarm Panel |
|
||
|
|
||
|
One channel for Zone 6 which is a sensor type channel, and one channel for the out pin that is an actuator type channel.
|
||
|
These channels represent the two pins on the Konnected Alarm Panel whose type cannot be changed.
|
||
|
For zones 1-5, you will need to add channels for the remaining zones that you have connected and configure them with the appropriate configuration parameters for each channel.
|
||
|
|
||
|
|
||
|
| Channel Type | Item Type | Config Parameters | Description |
|
||
|
|--------------|----------------------|----------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|
||
|
| Switch | Switch | Zone Number | This is the channel type for sensors or other read only devices |
|
||
|
| Actuator | Switch | Zone Number, Momentary, Pause, Times | This is the channel type for devices whose state can be turned on an off by the Konnected Alarm Panel |
|
||
|
| Temperature | Number:Temperature | Zone Number, DHT22, Poll Interval, DS18b20 Address | This is the channel for sensors which measure temperature (DHT22 and DS18B20). The DHT22 setting should be set to true when the channel is monitoring a zone connected to a DHT22 sensor and false if the zone is connected to a DS1820B sensor |
|
||
|
| Humidity | Number:Dimensionless | Zone Number | This is the channel type for the humidity sensor on a connected DHT22 sensor |
|
||
|
|
||
|
You will need to configure each channel with the appropriate zone number corresponding to the zone on The Konnected Alarm Panel.
|
||
|
Then you need to link the corresponding item to the channel.
|
||
|
|
||
|
For the actuator type channels you can also add configuration parameters times, pause and momentary which will be added to the payload that is sent to the Konnected Alarm Panel.
|
||
|
These parameters will tell the module to pulse the actuator for certain time period.
|
||
|
A momentary switch actuates a switch for a specified time (in milliseconds) and then reverts it back to the off state.
|
||
|
This is commonly used with a relay module to actuate a garage door opener, or with a door bell to send a momentary trigger to sound the door bell.
|
||
|
A beep/blink switch is like a momentary switch that repeats either a specified number of times or indefinitely.
|
||
|
This is commonly used with a piezo buzzer to make a "beep beep" sound when a door is opened, or to make a repeating beep pattern for an alarm or audible warning.
|
||
|
It can also be used to blink lights.
|
||
|
|
||
|
DSB1820 temperature probes.
|
||
|
These are one wire devices which can all be Konnected to the same "Zone" on the Konnected Alarm Panel.
|
||
|
As part of its transmission the module will include an unique "address" property of each sensor probe that will be logged to the debug log when received.
|
||
|
This needs to be added to the channel if there are multiple probes connected.
|
||
|
The default behavior in absence of this configuration will be to simply log the address of the received event.
|
||
|
A channel should be added for each probe, as indicated above and configured with the appropriate address.
|
||
|
|
||
|
|
||
|
## Full Example
|
||
|
|
||
|
*.items
|
||
|
|
||
|
```
|
||
|
Contact Front_Door_Sensor "Front Door" {channel="konnected:module:generic:switch"}
|
||
|
Switch Siren "Siren" {channel="konnected:module:generic:actuator"}
|
||
|
```
|
||
|
|
||
|
*.sitemap
|
||
|
|
||
|
```
|
||
|
Switch item=Front_Door_Sensor label="Front Door" icon="door" mappings=[OPEN="Open", CLOSED="Closed"]
|
||
|
Switch item=Siren label="Alarm Siren" icon="Siren" mappings=[ON="Open", OFF="Closed"]
|
||
|
```
|
||
|
|
||
|
*.things
|
||
|
|
||
|
```
|
||
|
Thing konnected:module:generic "Konnected Module" [ipAddress="http://192.168.30.153:9586", macAddress="1586517"]{
|
||
|
Type switch : switch "Front Door" [channel_zone=1]
|
||
|
Type actuator : actuator "Siren" [channel_zone=1, momentary = 50, times = 2, pause = 50]
|
||
|
Type humidity : humidity "DHT - Humidity" [channel_zone=1]
|
||
|
Type temperature : temperature "DHT Temperature" [channel_zone=1, tempsensorType = true, pollinterval = 1]
|
||
|