-`refreshInterval` Time (in seconds) between monitoring requests to the air unit. Smaller values mean more network load, typically set between a few seconds and a minute. Defaults to 10 seconds.
-`updateUnchangedValuesEveryMillis` Minimum time between state updates sent to the event bus for a particular channel when the state of the channel didn't change. This should avoid spamming the event bus with unnecessary updates. When set to 0, all channel state are updated every time the air unit requests are sent (see refresh interval). When set to a non zero value, unchanged values are only reported after the configured timespan has passed. Changed values are always sent to the event bus. Defaults to 60.000 (one minute), so updates are sent every minute or if the state of the channel changes.
| current_time | main | DateTime | RO | Current time reported by the air unit. |
| mode | main | String | RW | Value to control the operation mode of the air unit. One of DEMAND, PROGRAM, MANUAL and OFF |
| manual_fan_step | main | Dimmer | RW | Value to control the fan step when in MANUAL mode (10 steps) |
| supply_fan_speed | main | Number:Frequency | RO | Current rotation of the fan supplying air to the rooms (in rpm) |
| extract_fan_speed | main | Number:Frequency | RO | Current rotation of the fan extracting air from the rooms (in rpm) |
| supply_fan_step | main | Dimmer | RO | Current step setting of the fan supplying air to the rooms |
| extract_fan_step | main | Dimmer | RO | Current step setting of the fan extracting air from the rooms |
| boost | main | Switch | RW | Enables fan boost |
| night_cooling | main | Switch | RW | Enables night cooling |
| room_temp | temps | Number:Temperature | RO | Temperature of the air in the room of the Air Dial |
| room_temp_calculated | temps | Number:Temperature | RO | Calculated Room Temperature |
| outdoor_temp | temps | Number:Temperature | RO | Temperature of the air outside |
| humidity | humidity | Number:Dimensionless | RO | Current relative humidity measured by the air unit |
| bypass | recuperator | Switch | RW | Disables the heat exchange. Useful in summer when room temperature is above target and outside temperature is below target. |
| supply_temp | recuperator | Number | RO | Temperature of air which is passed to the rooms |
| extract_temp | recuperator | Number | RO | Temperature of the air as extracted from the rooms |
| exhaust_temp | recuperator | Number | RO | Temperature of the air when pushed outside |
| battery_life | service | Number | RO | Remaining Air Dial Battery Level (percentage) |
| filter_life | service | Number | RO | Remaining life of filter until exchange is necessary (percentage) |
| filter_period | service | Number | RW | Number of months between filter replacements (between 3 and 12). This value affects calculation of filter_life by the unit, and might get overwritten by Air Dial or Link CC Controller. |